Literature DB >> 27190769

Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition.

Weitian Chen1, Queenie Chan1, Yì-Xiáng J Wáng1.   

Abstract

BACKGROUND: Liver fibrosis is a key feature in most chronic liver diseases. T1rho magnetic resonance imaging is a potentially important technique for noninvasive diagnosis, severity grading, and therapy monitoring of liver fibrosis. However, it remains challenging to perform robust T1rho quantification of liver on human subjects. One major reason is that the presence of rich blood signal in liver can cause artificially high T1rho measurement and makes T1rho quantification susceptible to motion.
METHODS: A pulse sequence based on single shot fast/turbo spin echo (SSFSE/SSTSE) acquisition, with theoretical analysis and simulation based on the extended phase graph (EPG) algorithm, was presented for breath-hold single slice quantitative T1rho imaging of liver with suppression of blood signal. The pulse sequence was evaluated in human subjects at 3.0 T with 500 Hz spinlock frequency and time-of-spinlock (TSL) 0, 10, 30 and 50 ms.
RESULTS: Human scan demonstrated that the entire T1rho data sets with four spinlock time can be acquired within a single breath-hold of 10 seconds with black blood effect. T1rho quantification with suppression of blood signal results in significantly reduced T1rho value of liver compared to the results without blood suppression.
CONCLUSIONS: A signal-to-noise ratio (SNR) efficient pulse sequence was reported for T1rho quantification of liver. The black blood effect, together with a short breath-hold, mitigates the risk of quantification errors as would occur in the conventional methods.

Entities:  

Keywords:  T1rho; black blood; fast spin echo (FSE); liver; quantitative imaging

Year:  2016        PMID: 27190769      PMCID: PMC4858471          DOI: 10.21037/qims.2016.04.05

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  29 in total

1.  Liver T1ρ MRI measurement in healthy human subjects at 3 T: a preliminary study with a two-dimensional fast-field echo sequence.

Authors:  M Deng; F Zhao; J Yuan; A T Ahuja; Y-X J Wang
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

2.  Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.

Authors:  Reed F Busse; Hari Hariharan; Anthony Vu; Jean H Brittain
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

3.  Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections.

Authors:  Walter R T Witschey; Arijitt Borthakur; Mark A Elliott; Eric Mellon; Sampreet Niyogi; Daniel J Wallman; Chenyang Wang; Ravinder Reddy
Journal:  J Magn Reson       Date:  2007-01-26       Impact factor: 2.229

4.  Fast selective black blood MR imaging.

Authors:  R R Edelman; D Chien; D Kim
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

5.  Liver biopsy:complications and risk factors.

Authors:  Pornpen Thampanitchawong; Teerha Piratvisuth
Journal:  World J Gastroenterol       Date:  1999-08       Impact factor: 5.742

6.  Gradient reversal technique and its applications to chemical-shift-related NMR imaging.

Authors:  H W Park; D J Kim; Z H Cho
Journal:  Magn Reson Med       Date:  1987-06       Impact factor: 4.668

7.  Variability of CubeQuant T1ρ, quantitative DESS T2, and cones sodium MRI in knee cartilage.

Authors:  C D Jordan; E J McWalter; U D Monu; R D Watkins; W Chen; N K Bangerter; B A Hargreaves; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2014-10       Impact factor: 6.576

8.  MR T1ρ as an imaging biomarker for monitoring liver injury progression and regression: an experimental study in rats with carbon tetrachloride intoxication.

Authors:  Feng Zhao; Yi-Xiang J Wang; Jing Yuan; Min Deng; Hing Lok Wong; Eagle S H Chu; Minnie Y Y Go; Gao-Jun Teng; Anil T Ahuja; Jun Yu
Journal:  Eur Radiol       Date:  2012-03-27       Impact factor: 5.315

9.  Evaluation of fibrotic liver disease with whole-liver T1ρ MR imaging: a feasibility study at 1.5 T.

Authors:  Thomas Allkemper; Florian Sagmeister; Vito Cicinnati; Susanne Beckebaum; Hendrik Kooijman; Christian Kanthak; Christoph Stehling; Walter Heindel
Journal:  Radiology       Date:  2013-12-13       Impact factor: 11.105

10.  T1ρ MRI of healthy and fibrotic human livers at 1.5 T.

Authors:  Anup Singh; Damodar Reddy; Mohammad Haris; Kejia Cai; K Rajender Reddy; Hari Hariharan; Ravinder Reddy
Journal:  J Transl Med       Date:  2015-09-08       Impact factor: 5.531

View more
  5 in total

1.  Black blood T1rho MR imaging may diagnose early stage liver fibrosis: a proof-of-principle study with rat biliary duct ligation model.

Authors:  Chi-Man Koon; Xin Zhang; Weitian Chen; Eagle Siu Hong Chu; Clara Bik San Lau; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-08

2.  Volumetric multicomponent T relaxation mapping of the human liver under free breathing at 3T.

Authors:  Azadeh Sharafi; Rahman Baboli; Marcelo Zibetti; Krishna Shanbhogue; Sonja Olsen; Tobias Block; Hersh Chandarana; Ravinder Regatte
Journal:  Magn Reson Med       Date:  2019-11-14       Impact factor: 4.668

3.  Impact of Liver Fibrosis and Fatty Liver on T1rho Measurements: A Prospective Study.

Authors:  Shuangshuang Xie; Qing Li; Yue Cheng; Yu Zhang; Zhizheng Zhuo; Guiming Zhao; Wen Shen
Journal:  Korean J Radiol       Date:  2017-09-21       Impact factor: 3.500

4.  Inhomogeneous liver fibrosis distribution revealed by macromolecular proton fraction quantification based on spin-lock MRI.

Authors:  Yurui Qian; Vincent Wai-Sun Wong; Jian Hou; Baiyan Jiang; Winnie Chiu-Wing Chu; Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2022-08

5.  T magnetic resonance fingerprinting.

Authors:  Cory R Wyatt; Thomas M Barbara; Alexander R Guimaraes
Journal:  NMR Biomed       Date:  2020-03-03       Impact factor: 4.044

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.