Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (the Finapres).

J C Dorlas, J A Nijboer, W T Butijn, G M van der Hoeven, J J Settels, K H Wesseling.   

Abstract

The authors determined whether vasoconstriction alters the ability of a noninvasive method (Finapres) of continuously measuring arterial blood pressure in the finger to function accurately. They compared the response of the Finapres to blood pressures determined simultaneously by an oscillometric technique (Dinamap) in six anesthetized patients. Vasoconstriction was detected from a photoelectric plethysmogram, which was recorded continuously from an adjacent finger. Vasoconstriction was defined as a decrease in amplitude to less than half of its highest value in one and the same patient. From the 378 paired blood pressure readings obtained in this study, 51% took place in such a vasoconstricted state. The authors found that diastolic and mean blood pressures in the finger were, on the average, 9 mmHg below those in the upper arm and that the systolic pressure was 7 mmHg above that in the upper arm. The authors concluded that the Finapres keeps functioning well during peripheral vasoconstriction and is a recommendable method to monitor arterial blood pressure in the finger.

Entities:  

Mesh:

Year:  1985        PMID: 3977117     DOI: 10.1097/00000542-198503000-00022

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  22 in total

1.  Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry.

Authors:  Ron Dueck; Oliver Goedje; Paul Clopton
Journal:  J Clin Monit Comput       Date:  2012-01-18       Impact factor: 2.502

2.  On the reliability of the Penaz cuff during systemic and local fingertip vasodilatation at rest and in exercise.

Authors:  W Hildebrandt; H Schütze; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

3.  Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor.

Authors:  R H Epstein; S Huffnagle; R R Bartkowski
Journal:  J Clin Monit       Date:  1991-04

4.  Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation method.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1991-01       Impact factor: 2.602

5.  Continuous noninvasive arterial monitoring.

Authors:  C Salter
Journal:  West J Med       Date:  1988-07

6.  The relative accuracies of two automated noninvasive arterial pressure measurement devices.

Authors:  M S Gorback; T J Quill; M L Lavine
Journal:  J Clin Monit       Date:  1991-01

7.  Reliability of blood pressure determination with the Finapres with altered physiological states or pharmacodynamic conditions.

Authors:  D McAuley; B Silke; S Farrell
Journal:  Clin Auton Res       Date:  1997-08       Impact factor: 4.435

8.  Near-infrared spectroscopy determined cerebral oxygenation with eliminated skin blood flow in young males.

Authors:  Ai Hirasawa; Takahito Kaneko; Naoki Tanaka; Tsukasa Funane; Masashi Kiguchi; Henrik Sørensen; Niels H Secher; Shigehiko Ogoh
Journal:  J Clin Monit Comput       Date:  2015-05-29       Impact factor: 2.502

Review 9.  Smartphone Applications for Hypertension Management: a Potential Game-Changer That Needs More Control.

Authors:  Gianfranco Parati; Camilla Torlasco; Stefano Omboni; Dario Pellegrini
Journal:  Curr Hypertens Rep       Date:  2017-06       Impact factor: 5.369

10.  Noninvasive continuous blood pressure measurement from the finger: optimal measurement conditions and factors affecting reliability.

Authors:  T Kurki; N T Smith; N Head; H Dec-Silver; A Quinn
Journal:  J Clin Monit       Date:  1987-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.