Comparison of intra-arterial and automated oscillometric blood pressure measurement methods in postoperative hypertensive patients.

P G Loubser.   

Abstract

A comparison of blood pressures measured by direct radial intra-arterial and indirect brachial automated oscillometric methods (Dinamap 1845), was performed in thirty hypertensive post-carotid endarterectomy patients. Five hundred fifty-eight "triplet" readings of systolic, diastolic, and mean blood pressure were compared. Mean differences of 18.92, -6.32, and -0.26 mm Hg, and correlation coefficients of 0.831, 0.724, and 0.776 were calculated for systolic, diastolic, and mean blood pressures, respectively. Mean differences were then calculated within incremental direct systolic pressure ranges of 20 mm Hg and found to become significantly larger with each increasing increment of pressure. These differences ranged from -0.8 to 12.6 and 20.0 to 53.3 mm Hg in the less than 160 and greater than 160 mm Hg groups, respectively, with direct intra-arterial systolic pressures significantly greater than indirect oscillometric systolic pressures in the latter group. The results demonstrate that in the hypertensive pressure range, a significant difference exists in systolic pressure measured by intra-arterial and automated oscillometric methods.

Entities:  

Mesh:

Year:  1986        PMID: 3784934

Source DB:  PubMed          Journal:  Med Instrum        ISSN: 0090-6689


  8 in total

1.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

2.  Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor.

Authors:  R H Epstein; S Huffnagle; R R Bartkowski
Journal:  J Clin Monit       Date:  1991-04

3.  A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 "return-to-flow" method.

Authors:  F E Block; M V Fletcher; T J Morris; R Dzwonczyk
Journal:  J Clin Monit       Date:  1991-07

4.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01

5.  The relative accuracies of two automated noninvasive arterial pressure measurement devices.

Authors:  M S Gorback; T J Quill; M L Lavine
Journal:  J Clin Monit       Date:  1991-01

6.  Noninvasive blood pressure monitoring from the supraorbital artery using an artificial neural network oscillometric algorithm.

Authors:  S Narus; T Egbert; T K Lee; J Lu; D Westenskow
Journal:  J Clin Monit       Date:  1995-09

Review 7.  Evaluation and management of elevated blood pressures in hospitalized children.

Authors:  Abanti Chaudhuri; Scott M Sutherland
Journal:  Pediatr Nephrol       Date:  2018-08-31       Impact factor: 3.714

8.  Methods of blood pressure measurement in the ICU.

Authors:  Li-wei H Lehman; Mohammed Saeed; Daniel Talmor; Roger Mark; Atul Malhotra
Journal:  Crit Care Med       Date:  2013-01       Impact factor: 7.598

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.