Literature DB >> 2500393

Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

G Parati1, R Casadei, A Groppelli, M Di Rienzo, G Mancia.   

Abstract

The accuracy of blood pressure values obtained by continuous noninvasive finger blood pressure recording via the FINAPRES device was evaluated by comparison with simultaneous intraarterial monitoring both at rest and during performance of tests known to induce fast and often marked changes in blood pressure. The comparison was performed in 24 normotensive or essential hypertensive subjects. The average discrepancy between finger and intra-arterial blood pressure recorded over a 30-minute rest period was 6.5 +/- 2.6 mm Hg and 5.4 +/- 2.9 mm Hg for systolic and diastolic blood pressure, respectively; a close between-method correspondence was also demonstrated by linear regression analysis. The beat-to-beat changes in finger systolic and diastolic blood pressure were on average similar to those measured intra-arterially during tests that induced a pressor or depressor response (hand-grip, cold pressor test, diving test, Valsalva maneuver, intravenous injections of phenylephrine and trinitroglycerine) as well as during tests that caused vasomotor changes without major variations in blood pressure (application of lower body negative pressure, passive leg raising). The average between-method discrepancy in the evaluation of blood pressure changes was never greater than 4.3 and 2.0 mm Hg for systolic and diastolic blood pressure, respectively; the corresponding standard deviations ranged between 4.6 and 1.6 mm Hg. Beat-to-beat computer analysis of blood pressure variability over the 30-minute rest period provided standard deviations almost identical when calculated by separate consideration of intra-arterial and finger blood pressure tracings (3.7 and 3.8 mm Hg, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2500393     DOI: 10.1161/01.hyp.13.6.647

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  147 in total

1.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

2.  Two sites for modulation of human sympathetic activity by arterial baroreceptors?

Authors:  P Kienbaum; T Karlssonn; Y B Sverrisdottir; M Elam; B G Wallin
Journal:  J Physiol       Date:  2001-03-15       Impact factor: 5.182

3.  Exercise-induced muscle chemoreflex modulation of spontaneous baroreflex sensitivity in man.

Authors:  C A Carrington; M J White
Journal:  J Physiol       Date:  2001-11-01       Impact factor: 5.182

4.  Mechanism of blood pressure and R-R variability: insights from ganglion blockade in humans.

Authors:  Rong Zhang; Kenichi Iwasaki; Julie H Zuckerman; Khosrow Behbehani; Craig G Crandall; Benjamin D Levine
Journal:  J Physiol       Date:  2002-08-15       Impact factor: 5.182

5.  Training mode does not affect orthostatic tolerance in chronically exercising subjects.

Authors:  Warren D Franke; Kimberly K Mills; Kichang Lee; Juliane P Hernandez
Journal:  Eur J Appl Physiol       Date:  2003-02-28       Impact factor: 3.078

6.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

7.  Regulation of arterial blood pressure in humans during isometric muscle contraction and lower body negative pressure.

Authors:  Jonny Hisdal; Karin Toska; Torun Flatebø; Bjarne Waaler; Lars Walløe
Journal:  Eur J Appl Physiol       Date:  2003-11-01       Impact factor: 3.078

8.  Sympathetic nervous system activity during skin cooling in humans: relationship to stimulus intensity and pain sensation.

Authors:  K C Kregel; D R Seals; R Callister
Journal:  J Physiol       Date:  1992-08       Impact factor: 5.182

9.  Arterial pressure oscillations are not associated with muscle sympathetic nerve activity in individuals exposed to central hypovolaemia.

Authors:  Kathy L Ryan; Caroline A Rickards; Carmen Hinojosa-Laborde; William H Cooke; Victor A Convertino
Journal:  J Physiol       Date:  2011-09-19       Impact factor: 5.182

10.  On the reliability of the Penaz cuff during systemic and local fingertip vasodilatation at rest and in exercise.

Authors:  W Hildebrandt; H Schütze; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.