Automatic monitoring of localized skin dose with fluoroscopic and interventional procedures.

Yasaman Khodadadegan1, Muhong Zhang, William Pavlicek, Robert G Paden, Brian Chong, Beth A Schueler, Kenneth A Fetterly, Steve G Langer, Teresa Wu.   

Abstract

This software tool locates and computes the intensity of radiation skin dose resulting from fluoroscopically guided interventional procedures. It is comprised of multiple modules. Using standardized body specific geometric values, a software module defines a set of male and female patients arbitarily positioned on a fluoroscopy table. Simulated X-ray angiographic (XA) equipment includes XRII and digital detectors with or without bi-plane configurations and left and right facing tables. Skin dose estimates are localized by computing the exposure to each 0.01 × 0.01 m(2) on the surface of a patient irradiated by the X-ray beam. Digital Imaging and Communications in Medicine (DICOM) Structured Report Dose data sent to a modular dosimetry database automatically extracts the 11 XA tags necessary for peak skin dose computation. Skin dose calculation software uses these tags (gantry angles, air kerma at the patient entrance reference point, etc.) and applies appropriate corrections of exposure and beam location based on each irradiation event (fluoroscopy and acquistions). A physicist screen records the initial validation of the accuracy, patient and equipment geometry, DICOM compliance, exposure output calibration, backscatter factor, and table and pad attenuation once per system. A technologist screen specifies patient positioning, patient height and weight, and physician user. Peak skin dose is computed and localized; additionally, fluoroscopy duration and kerma area product values are electronically recorded and sent to the XA database. This approach fully addresses current limitations in meeting accreditation criteria, eliminates the need for paper logs at a XA console, and provides a method where automated ALARA montoring is possible including email and pager alerts.

Entities:  

Mesh:

Year:  2011        PMID: 20706859      PMCID: PMC3138926          DOI: 10.1007/s10278-010-9320-7

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  12 in total

1.  Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams.

Authors:  C M Ma; J P Seuntjens
Journal:  Phys Med Biol       Date:  1999-01       Impact factor: 3.609

2.  Radiation doses in interventional radiology procedures: the RAD-IR study: part II: skin dose.

Authors:  Donald L Miller; Stephen Balter; Patricia E Cole; Hollington T Lu; Alejandro Berenstein; Robin Albert; Beth A Schueler; Jeffrey D Georgia; Patrick T Noonan; Eric J Russell; Tim W Malisch; Robert L Vogelzang; Michael Geisinger; John F Cardella; James St George; George L Miller; Jon Anderson
Journal:  J Vasc Interv Radiol       Date:  2003-08       Impact factor: 3.464

3.  A mathematical model of a phantom developed for use in calculations of radiation dose to the body and major internal organs of a Japanese adult.

Authors:  G D Kerr; J M Hwang; R M Jones
Journal:  J Radiat Res       Date:  1976-12       Impact factor: 2.724

4.  A mathematical model for patient skin dose assessment in cardiac catheterization procedures.

Authors:  R E Morrell; A T Rogers
Journal:  Br J Radiol       Date:  2006-09       Impact factor: 3.039

5.  The new Joint Commission sentinel event pertaining to prolonged fluoroscopy.

Authors:  Stephen Balter; Donald L Miller
Journal:  J Am Coll Radiol       Date:  2007-07       Impact factor: 5.532

6.  Patient dosimetry for x rays used in medical imaging.

Authors: 
Journal:  J ICRU       Date:  2005-12

7.  Capturing patient doses from fluoroscopically based diagnostic and interventional systems.

Authors:  Stephen Balter
Journal:  Health Phys       Date:  2008-11       Impact factor: 1.316

8.  Minimizing radiation-induced skin injury in interventional radiology procedures.

Authors:  Donald L Miller; Stephen Balter; Patrick T Noonan; Jeffrey D Georgia
Journal:  Radiology       Date:  2002-11       Impact factor: 11.105

9.  [Medical electrical equipment-part 2-54: particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy, JIS Z 4751-2-54: 2012].

Authors:  Shinji Abe
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2014-02

10.  Entrance skin dose estimates derived from dose-area product measurements in interventional radiological procedures.

Authors:  B J McParland
Journal:  Br J Radiol       Date:  1998-12       Impact factor: 3.039

View more
  8 in total

1.  Skin dose mapping for fluoroscopically guided interventions.

Authors:  Perry B Johnson; David Borrego; Stephen Balter; Kevin Johnson; Daniel Siragusa; Wesley E Bolch
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  An automated DICOM database capable of arbitrary data mining (including radiation dose indicators) for quality monitoring.

Authors:  Shanshan Wang; William Pavlicek; Catherine C Roberts; Steve G Langer; Muhong Zhang; Mengqi Hu; Richard L Morin; Beth A Schueler; Clinton V Wellnitz; Teresa Wu
Journal:  J Digit Imaging       Date:  2011-04       Impact factor: 4.056

3.  Real-time eye lens dose monitoring during cerebral angiography procedures.

Authors:  M J Safari; J H D Wong; K A A Kadir; N K Thorpe; D L Cutajar; M Petasecca; M L F Lerch; A B Rosenfeld; K H Ng
Journal:  Eur Radiol       Date:  2015-05-23       Impact factor: 5.315

4.  Reference air kerma and kerma-area product as estimators of peak skin dose for fluoroscopically guided interventions.

Authors:  Deukwoo Kwon; Mark P Little; Donald L Miller
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

5.  A new method of real-time skin dose visualization. Clinical evaluation of fluoroscopically guided interventions.

Authors:  Fazel Boujan; Nicolas Clauss; Emilie Santos; Sjirk Boon; Gerard Schouten; Luc Mertz; Jean-Louis Dietemann
Journal:  Neuroradiology       Date:  2014-08-17       Impact factor: 2.804

6.  Organ doses in pediatric patients undergoing cardiac-centered fluoroscopically guided interventions: Comparison of three methods for computational phantom alignment.

Authors:  Emily L Marshall; David Borrego; James C Fudge; Dhanashree Rajderkar; Wesley E Bolch
Journal:  Med Phys       Date:  2018-06-13       Impact factor: 4.071

7.  Evaluation of skin dose calculation factors in interventional fluoroscopy.

Authors:  Matthew C DeLorenzo; Allen R Goode
Journal:  J Appl Clin Med Phys       Date:  2019-09-30       Impact factor: 2.102

8.  Vendor-independent skin dose mapping application for interventional radiology and cardiology.

Authors:  Marko Krajinović; Nikola Kržanović; Olivera Ciraj-Bjelac
Journal:  J Appl Clin Med Phys       Date:  2021-01-13       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.