Literature DB >> 20824303

An automated DICOM database capable of arbitrary data mining (including radiation dose indicators) for quality monitoring.

Shanshan Wang1, William Pavlicek, Catherine C Roberts, Steve G Langer, Muhong Zhang, Mengqi Hu, Richard L Morin, Beth A Schueler, Clinton V Wellnitz, Teresa Wu.   

Abstract

The U.S. National Press has brought to full public discussion concerns regarding the use of medical radiation, specifically x-ray computed tomography (CT), in diagnosis. A need exists for developing methods whereby assurance is given that all diagnostic medical radiation use is properly prescribed, and all patients' radiation exposure is monitored. The "DICOM Index Tracker©" (DIT) transparently captures desired digital imaging and communications in medicine (DICOM) tags from CT, nuclear imaging equipment, and other DICOM devices across an enterprise. Its initial use is recording, monitoring, and providing automatic alerts to medical professionals of excursions beyond internally determined trigger action levels of radiation. A flexible knowledge base, aware of equipment in use, enables automatic alerts to system administrators of newly identified equipment models or software versions so that DIT can be adapted to the new equipment or software. A dosimetry module accepts mammography breast organ dose, skin air kerma values from XA modalities, exposure indices from computed radiography, etc. upon receipt. The American Association of Physicists in Medicine recommended a methodology for effective dose calculations which are performed with CT units having DICOM structured dose reports. Web interface reporting is provided for accessing the database in real-time. DIT is DICOM-compliant and, thus, is standardized for international comparisons. Automatic alerts currently in use include: email, cell phone text message, and internal pager text messaging. This system extends the utility of DICOM for standardizing the capturing and computing of radiation dose as well as other quality measures.

Entities:  

Mesh:

Year:  2011        PMID: 20824303      PMCID: PMC3056966          DOI: 10.1007/s10278-010-9329-y

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  13 in total

1.  Differences in effective dose estimation from dose-area product and entrance surface dose measurements in intravenous urography.

Authors:  E Yakoumakis; I A Tsalafoutas; D Nikolaou; I Nazos; E Koulentianos; C Proukakis
Journal:  Br J Radiol       Date:  2001-08       Impact factor: 3.039

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

3.  American College of Radiology white paper on radiation dose in medicine.

Authors:  E Stephen Amis; Priscilla F Butler; Kimberly E Applegate; Steven B Birnbaum; Libby F Brateman; James M Hevezi; Fred A Mettler; Richard L Morin; Michael J Pentecost; Geoffrey G Smith; Keith J Strauss; Robert K Zeman
Journal:  J Am Coll Radiol       Date:  2007-05       Impact factor: 5.532

4.  Radiation doses associated with cardiac computed tomography angiography.

Authors:  Razvan C Opreanu; John P Kepros
Journal:  JAMA       Date:  2009-06-10       Impact factor: 56.272

5.  Image retake analysis in digital radiography using DICOM header information.

Authors:  C Prieto; E Vano; J I Ten; J M Fernandez; A I Iñiguez; N Arevalo; A Litcheva; E Crespo; A Floriano; D Martinez
Journal:  J Digit Imaging       Date:  2008-07-01       Impact factor: 4.056

Review 6.  Issues surrounding PACS archiving to external, third-party DICOM archives.

Authors:  Steve Langer
Journal:  J Digit Imaging       Date:  2008-05-01       Impact factor: 4.056

7.  Developing a multi-institutional PACS archive and designing processes to manage the shift from a film to a digital-based archive.

Authors:  Nicole K Laprise; Richard Hanusik; T J Fitzgerald; Nancy Rosen; Keith S White
Journal:  J Digit Imaging       Date:  2007-10-09       Impact factor: 4.056

8.  Automatic monitoring of localized skin dose with fluoroscopic and interventional procedures.

Authors:  Yasaman Khodadadegan; Muhong Zhang; William Pavlicek; Robert G Paden; Brian Chong; Beth A Schueler; Kenneth A Fetterly; Steve G Langer; Teresa Wu
Journal:  J Digit Imaging       Date:  2011-08       Impact factor: 4.056

9.  Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography.

Authors:  Andrew J Einstein; Milena J Henzlova; Sanjay Rajagopalan
Journal:  JAMA       Date:  2007-07-18       Impact factor: 56.272

Review 10.  The challenges, opportunities, and imperative of structured reporting in medical imaging.

Authors:  Bruce I Reiner
Journal:  J Digit Imaging       Date:  2009-12       Impact factor: 4.056

View more
  18 in total

1.  A flexible database architecture for mining DICOM objects: the DICOM data warehouse.

Authors:  Steve G Langer
Journal:  J Digit Imaging       Date:  2012-04       Impact factor: 4.056

2.  Falling prey to the sunk cost bias: a potential harm of patient radiation dose histories.

Authors:  Jonathan D Eisenberg; H Benjamin Harvey; Donald A Moore; G Scott Gazelle; Pari V Pandharipande
Journal:  Radiology       Date:  2012-06       Impact factor: 11.105

Review 3.  [Dose management in radiology: Review of the technological status].

Authors:  M Verius
Journal:  Radiologe       Date:  2015-08       Impact factor: 0.635

4.  Anatomy of an Extensible Open Source PACS.

Authors:  Frederico Valente; Luís A Bastião Silva; Tiago Marques Godinho; Carlos Costa
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

5.  DICOM Data Warehouse: Part 2.

Authors:  Steve G Langer
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

Review 6.  Current and future trends in imaging informatics for oncology.

Authors:  Mia A Levy; Daniel L Rubin
Journal:  Cancer J       Date:  2011 Jul-Aug       Impact factor: 3.360

7.  Prioritizing examination-centered over patient-centered dose reduction: a hazard of institutional "benchmarking".

Authors:  Jonathan D Eisenberg; Michael E Gilmore; Mannudeep K Kalra; Chung Yin Kong; Pari V Pandharipande
Journal:  AJR Am J Roentgenol       Date:  2014-05       Impact factor: 3.959

8.  Normalizing Heterogeneous Medical Imaging Data to Measure the Impact of Radiation Dose.

Authors:  Luís A Bastião Silva; Luís S Ribeiro; Milton Santos; Nuno Neves; Dulce Francisco; Carlos Costa; José Luis Oliveira
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

9.  Automated detection of z-axis coverage with abdomen-pelvis computed tomography examinations.

Authors:  Min Zhang; Clinton Wellnitz; Can Cui; William Pavlicek; Teresa Wu
Journal:  J Digit Imaging       Date:  2015-06       Impact factor: 4.056

10.  Usage of structured reporting in radiological practice: results from an Italian online survey.

Authors:  Lorenzo Faggioni; Francesca Coppola; Riccardo Ferrari; Emanuele Neri; Daniele Regge
Journal:  Eur Radiol       Date:  2016-08-29       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.