Function of an implanted tissue glucose sensor for more than 1 year in animals.

David A Gough1, Lucas S Kumosa, Timothy L Routh, Joe T Lin, Joseph Y Lucisano.   

Abstract

An implantable sensor capable of long-term monitoring of tissue glucose concentrations by wireless telemetry has been developed for eventual application in people with diabetes. The sensor telemetry system functioned continuously while implanted in subcutaneous tissues of two pigs for a total of 222 and 520 days, respectively, with each animal in both nondiabetic and diabetic states. The sensor detects glucose via an enzyme electrode that is based on differential electrochemical oxygen detection, which reduces the sensitivity of the sensor to encapsulation by the body, variations in local microvascular perfusion, limited availability of tissue oxygen, and inactivation of the enzymes. After an initial 2-week stabilization period, the implanted sensors maintained stability of calibration for extended periods. The lag between blood and tissue glucose concentrations was 11.8 +/- 5.7 and 6.5 +/- 13.3 minutes (mean +/- standard deviation), respectively, for rising and falling blood glucose challenges. The lag resulted mainly from glucose mass transfer in the tissues, rather than the intrinsic response of the sensor, and showed no systematic change over implant test periods. These results represent a milestone in the translation of the sensor system to human applications.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20668297      PMCID: PMC4528300          DOI: 10.1126/scitranslmed.3001148

Source DB:  PubMed          Journal:  Sci Transl Med        ISSN: 1946-6234            Impact factor:   17.956


  30 in total

1.  Simulations of the frequency response of implantable glucose sensors.

Authors:  M Jablecki; D A Gough
Journal:  Anal Chem       Date:  2000-04-15       Impact factor: 6.986

2.  Tissue window chamber system for validation of implanted oxygen sensors.

Authors:  Milan T Makale; Joe T Lin; Richard E Calou; Amy G Tsai; Peter C Chen; David A Gough
Journal:  Am J Physiol Heart Circ Physiol       Date:  2003-02-21       Impact factor: 4.733

Review 3.  Continuous glucose monitoring: roadmap for 21st century diabetes therapy.

Authors:  David C Klonoff
Journal:  Diabetes Care       Date:  2005-05       Impact factor: 19.112

4.  Time-dependent inactivation of immobilized glucose oxidase and catalase.

Authors:  P H Tse; D A Gough
Journal:  Biotechnol Bioeng       Date:  1987-04       Impact factor: 4.530

5.  A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors.

Authors:  B D McKean; D A Gough
Journal:  IEEE Trans Biomed Eng       Date:  1988-07       Impact factor: 4.538

6.  Continuous blood glucose analysis in ambulatory fed subjects. I. General methodology.

Authors:  G D Molnar; E Ackerman; J W Rosevear; L C Gatewood; K E Moxness
Journal:  Mayo Clin Proc       Date:  1968-12       Impact factor: 7.616

7.  In vitro stability of an oxygen sensor.

Authors:  J Y Lucisano; J C Armour; D A Gough
Journal:  Anal Chem       Date:  1987-03-01       Impact factor: 6.986

Review 8.  Oxygen gradients in the microcirculation.

Authors:  Amy G Tsai; Paul C Johnson; Marcos Intaglietta
Journal:  Physiol Rev       Date:  2003-07       Impact factor: 37.312

9.  A simple technique for preservation of fixation-sensitive antigens in paraffin-embedded tissues.

Authors:  J H Beckstead
Journal:  J Histochem Cytochem       Date:  1994-08       Impact factor: 2.479

10.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

View more
  38 in total

1.  Comparison of Insulins Glargine and Degludec in Diabetic Rhesus Macaques (Macaca mulatta) with CGM Devices.

Authors:  Samantha C Puglisi; Alexis L Mackiewicz; Amir Ardeshir; Laura M Garzel; Kari L Christe
Journal:  Comp Med       Date:  2021-05-25       Impact factor: 0.982

2.  Characterization of porous, dexamethasone-releasing polyurethane coatings for glucose sensors.

Authors:  Suzana G Vallejo-Heligon; Bruce Klitzman; William M Reichert
Journal:  Acta Biomater       Date:  2014-07-25       Impact factor: 8.947

Review 3.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

4.  Clinical Use of Continuous Glucose Monitoring in Pediatrics.

Authors:  Rayhan A Lal; David M Maahs
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

5.  Scanning electrochemical microscopy as a novel proximity sensor for atraumatic cochlear implant insertion.

Authors:  H Watanabe; J Velmurugan; M V Mirkin; M A Svirsky; A K Lalwani; R R Llinas
Journal:  IEEE Trans Biomed Eng       Date:  2014-06       Impact factor: 4.538

Review 6.  Stimuli sensitive polymers and self regulated drug delivery systems: a very partial review.

Authors:  Ronald A Siegel
Journal:  J Control Release       Date:  2014-06-28       Impact factor: 9.776

Review 7.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

8.  Assessment of a Noninvasive Chronic Glucose Monitoring System in Euglycemic and Diabetic Swine (Sus scrofa).

Authors:  Rebecca A Ober; Gail E Geist
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-04-13       Impact factor: 1.232

9.  Redundancy in Glucose Sensing: Enhanced Accuracy and Reliability of an Electrochemical Redundant Sensor for Continuous Glucose Monitoring.

Authors:  Amin Sharifi; Andrea Varsavsky; Johanna Ulloa; Jodie C Horsburgh; Sybil A McAuley; Balasubramanian Krishnamurthy; Alicia J Jenkins; Peter G Colman; Glenn M Ward; Richard J MacIsaac; Rajiv Shah; David N O'Neal
Journal:  J Diabetes Sci Technol       Date:  2016-05-03

10.  Permeability of subcutaneous tissues surrounding long-term implants to oxygen.

Authors:  Lucas S Kumosa; Timothy L Routh; Joe T Lin; Joseph Y Lucisano; David A Gough
Journal:  Biomaterials       Date:  2014-07-04       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.