Literature DB >> 25065548

Characterization of porous, dexamethasone-releasing polyurethane coatings for glucose sensors.

Suzana G Vallejo-Heligon1, Bruce Klitzman2, William M Reichert3.   

Abstract

Commercially available implantable needle-type glucose sensors for diabetes management are robust analytically but can be unreliable clinically primarily due to tissue-sensor interactions. Here, we present the physical, drug release and bioactivity characterization of tubular, porous dexamethasone (Dex)-releasing polyurethane coatings designed to attenuate local inflammation at the tissue-sensor interface. Porous polyurethane coatings were produced by the salt-leaching/gas-foaming method. Scanning electron microscopy and micro-computed tomography (micro-CT) showed controlled porosity and coating thickness. In vitro drug release from coatings monitored over 2 weeks presented an initial fast release followed by a slower release. Total release from coatings was highly dependent on initial drug loading amount. Functional in vitro testing of glucose sensors deployed with porous coatings against glucose standards demonstrated that highly porous coatings minimally affected signal strength and response rate. Bioactivity of the released drug was determined by monitoring Dex-mediated, dose-dependent apoptosis of human peripheral blood derived monocytes in culture. Acute animal studies were used to determine the appropriate Dex payload for the implanted porous coatings. Pilot short-term animal studies showed that Dex released from porous coatings implanted in rat subcutis attenuated the initial inflammatory response to sensor implantation. These results suggest that deploying sensors with the porous, Dex-releasing coatings is a promising strategy to improve glucose sensor performance.
Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biosensor; Controlled drug release; Foreign body response; Inflammation; Porosity

Mesh:

Substances:

Year:  2014        PMID: 25065548      PMCID: PMC4186909          DOI: 10.1016/j.actbio.2014.07.019

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  40 in total

Review 1.  Continuous glucose monitoring: roadmap for 21st century diabetes therapy.

Authors:  David C Klonoff
Journal:  Diabetes Care       Date:  2005-05       Impact factor: 19.112

Review 2.  In vitro, in vivo and post explantation testing of glucose-detecting biosensors: current methods and recommendations.

Authors:  Heidi E Koschwanez; William M Reichert
Journal:  Biomaterials       Date:  2007-04-19       Impact factor: 12.479

3.  Segmented polyurethane intravaginal rings for the sustained combined delivery of antiretroviral agents dapivirine and tenofovir.

Authors:  Todd J Johnson; Kavita M Gupta; Judit Fabian; Theodore H Albright; Patrick F Kiser
Journal:  Eur J Pharm Sci       Date:  2009-12-01       Impact factor: 4.384

4.  Predicting glucose sensor behavior in blood using transport modeling: relative impacts of protein biofouling and cellular metabolic effects.

Authors:  Matthew T Novak; Fan Yuan; William M Reichert
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

5.  Characterization of cellular response to silicone implants in rats: implications for foreign-body carcinogenesis.

Authors:  S J James; M Pogribna; B J Miller; B Bolon; L Muskhelishvili
Journal:  Biomaterials       Date:  1997-05       Impact factor: 12.479

6.  Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation.

Authors:  Matthew T Novak; Fan Yuan; William M Reichert
Journal:  Anal Bioanal Chem       Date:  2010-08-28       Impact factor: 4.142

7.  In vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors.

Authors:  H E Koschwanez; F Y Yap; B Klitzman; W M Reichert
Journal:  J Biomed Mater Res A       Date:  2008-12-01       Impact factor: 4.396

8.  Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans.

Authors:  Barbara C Gilligan; Mark Shults; Rathbun K Rhodes; Peter G Jacobs; James H Brauker; Thomas J Pintar; Stuart J Updike
Journal:  Diabetes Technol Ther       Date:  2004-06       Impact factor: 6.118

9.  Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors.

Authors:  C A Quinn; R E Connor; A Heller
Journal:  Biomaterials       Date:  1997-12       Impact factor: 12.479

10.  Dexamethasone-releasing biodegradable polymer scaffolds fabricated by a gas-foaming/salt-leaching method.

Authors:  Jun Jin Yoon; Jung Hoe Kim; Tae Gwan Park
Journal:  Biomaterials       Date:  2003-06       Impact factor: 12.479

View more
  9 in total

Review 1.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

2.  PLGA microsphere/PVA hydrogel coatings suppress the foreign body reaction for 6 months.

Authors:  Bing Gu; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Control Release       Date:  2018-09-24       Impact factor: 9.776

3.  Effects of delayed delivery of dexamethasone-21-phosphate via subcutaneous microdialysis implants on macrophage activation in rats.

Authors:  Geoffrey D Keeler; Jeannine M Durdik; Julie A Stenken
Journal:  Acta Biomater       Date:  2015-05-15       Impact factor: 8.947

Review 4.  Biomedical Imaging in Implantable Drug Delivery Systems.

Authors:  Haoyan Zhou; Christopher Hernandez; Monika Goss; Anna Gawlik; Agata A Exner
Journal:  Curr Drug Targets       Date:  2015       Impact factor: 3.465

5.  Influence of diabetes on the foreign body response to nitric oxide-releasing implants.

Authors:  Robert J Soto; Elizabeth P Merricks; Dwight A Bellinger; Timothy C Nichols; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2017-11-30       Impact factor: 12.479

Review 6.  Modulating the foreign body response of implants for diabetes treatment.

Authors:  Bhushan N Kharbikar; Gauree S Chendke; Tejal A Desai
Journal:  Adv Drug Deliv Rev       Date:  2021-01-21       Impact factor: 17.873

7.  Polycaprolactone nanofibrous mesh reduces foreign body reaction and induces adipose flap expansion in tissue engineering chamber.

Authors:  Lin Luo; Yunfan He; Qiang Chang; Gan Xie; Weiqing Zhan; Xuecen Wang; Tao Zhou; Malcolm Xing; Feng Lu
Journal:  Int J Nanomedicine       Date:  2016-12-05

Review 8.  Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review.

Authors:  Daniela Rodrigues; Ana I Barbosa; Rita Rebelo; Il Keun Kwon; Rui L Reis; Vitor M Correlo
Journal:  Biosensors (Basel)       Date:  2020-07-21

9.  Porous, Dexamethasone-loaded polyurethane coatings extend performance window of implantable glucose sensors in vivo.

Authors:  Suzana G Vallejo-Heligon; Nga L Brown; William M Reichert; Bruce Klitzman
Journal:  Acta Biomater       Date:  2015-10-29       Impact factor: 8.947

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.