Literature DB >> 32284091

Assessment of a Noninvasive Chronic Glucose Monitoring System in Euglycemic and Diabetic Swine (Sus scrofa).

Rebecca A Ober, Gail E Geist.   

Abstract

Models of type-I diabetes are well-characterized and commonly used in the preclinical evaluation of drugs and medical devices. The diabetic minipig is an excellent example of a translational model. However, chronic glucose monitoring in this species can be challenging; frequent blood sampling can be technically difficult and poorly tolerated in conscious swine. Skin-patch continuous blood glucose monitors are FDA-approved for human use and offer a potential refinement to cageside blood collection. However, this modality has not been evaluated in pigs. In this study, young adult male STZ-induced diabetic Yucatan minipigs (n = 4) and healthy York pigs (n = 4) were implanted with a 14-d skin-patch continuous glucose monitor. Readings from continuous glucose monitors were time-matched to whole blood samples, with glucose measurements performed using point-of-care blood glucose monitors, serum chemistry or both. The aims of the study were to assess if a continuous glucose monitoring system could accurately detect glucose levels in swine, and to compare the readings toboth point-of-care glucometers and serum chemistry results. We hypothesized that a continuous glucose monitoring system would accurately detect glucose levels in swine in comparison with a validated analyzer and could serve as an animal welfarerefinement for studies of diabetes. We found that the continuous glucose monitor used in this study provided an adequateadjunct for clinical management in the stable diabetic pig and a minimally invasive and inexpensive option for colony maintenanceof chronically diabetic swine.

Entities:  

Year:  2020        PMID: 32284091      PMCID: PMC7338878          DOI: 10.30802/AALAS-JAALAS-19-000140

Source DB:  PubMed          Journal:  J Am Assoc Lab Anim Sci        ISSN: 1559-6109            Impact factor:   1.232


  38 in total

1.  Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial.

Authors:  Jan Bolinder; Ramiro Antuna; Petronella Geelhoed-Duijvestijn; Jens Kröger; Raimund Weitgasser
Journal:  Lancet       Date:  2016-09-12       Impact factor: 79.321

2.  Computing the surveillance error grid analysis: procedure and examples.

Authors:  Boris P Kovatchev; Christian A Wakeman; Marc D Breton; Gerald J Kost; Richard F Louie; Nam K Tran; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2014-06-13

Review 3.  Can interstitial glucose assessment replace blood glucose measurements?

Authors:  K Rebrin; G M Steil
Journal:  Diabetes Technol Ther       Date:  2000       Impact factor: 6.118

4.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

5.  Evaluation of a continuous glucose monitoring system for use in dogs, cats, and horses.

Authors:  Charles E Wiedmeyer; Philip J Johnson; Leah A Cohn; Richard L Meadows
Journal:  J Am Vet Med Assoc       Date:  2003-10-01       Impact factor: 1.936

6.  Use of the continuous glucose monitoring system in Goettingen Minipigs, with a special focus on the evaluation of insulin-dependent diabetes.

Authors:  A Strauss; C Tiurbe; I Chodnevskaja; A Thiede; S Timm; K Ulrichs; V Moskalenko
Journal:  Transplant Proc       Date:  2008-03       Impact factor: 1.066

7.  Investigation of the Accuracy of 18 Marketed Blood Glucose Monitors.

Authors:  David C Klonoff; Joan Lee Parkes; Boris P Kovatchev; David Kerr; Wendy C Bevier; Ronald L Brazg; Mark Christiansen; Timothy S Bailey; James H Nichols; Michael A Kohn
Journal:  Diabetes Care       Date:  2018-06-13       Impact factor: 19.112

8.  The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.

Authors:  Timothy Bailey; Bruce W Bode; Mark P Christiansen; Leslie J Klaff; Shridhara Alva
Journal:  Diabetes Technol Ther       Date:  2015-07-14       Impact factor: 6.118

9.  Variability of capillary blood glucose monitoring measured on home glucose monitoring devices.

Authors:  Narendra Kotwal; Aditi Pandit
Journal:  Indian J Endocrinol Metab       Date:  2012-12

10.  Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs.

Authors:  S Corradini; B Pilosio; F Dondi; G Linari; S Testa; F Brugnoli; P Gianella; M Pietra; F Fracassi
Journal:  J Vet Intern Med       Date:  2016-06-18       Impact factor: 3.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.