Literature DB >> 12598234

Tissue window chamber system for validation of implanted oxygen sensors.

Milan T Makale1, Joe T Lin, Richard E Calou, Amy G Tsai, Peter C Chen, David A Gough.   

Abstract

An experimental system is described for validating electrochemical oxygen sensors implanted in tissues. The system is a modified hamster window chamber in which a thin layer of vascularized tissue is held between two plates, one plate having an observation window and the other plate having an array of oxygen sensors. This arrangement permits simultaneous recording of oxygen sensor signals and nondestructive visualization of the tissue adjacent to the sensors over periods of 1 mo or more, without the inhibitory effects of anesthesia. The system provides a means for study of the effects of spatial and temporal oxygen distributions on the sensor signals and adaptation of the tissue structure over time. Examples are given of sensor recordings and images of tissues with implanted oxygen sensor arrays.

Entities:  

Mesh:

Year:  2003        PMID: 12598234     DOI: 10.1152/ajpheart.00721.2002

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  8 in total

Review 1.  In vitro, in vivo and post explantation testing of glucose-detecting biosensors: current methods and recommendations.

Authors:  Heidi E Koschwanez; William M Reichert
Journal:  Biomaterials       Date:  2007-04-19       Impact factor: 12.479

2.  Function of an implanted tissue glucose sensor for more than 1 year in animals.

Authors:  David A Gough; Lucas S Kumosa; Timothy L Routh; Joe T Lin; Joseph Y Lucisano
Journal:  Sci Transl Med       Date:  2010-07-28       Impact factor: 17.956

3.  Percutaneous window chamber method for chronic intravital microscopy of sensor-tissue interactions.

Authors:  Heidi E Koschwanez; Bruce Klitzman; W Monty Reichert
Journal:  J Diabetes Sci Technol       Date:  2008-11

4.  Multi-modality imaging of a murine mammary window chamber for breast cancer research.

Authors:  Rachel Schafer; Hui Min Leung; Arthur F Gmitro
Journal:  Biotechniques       Date:  2014-07-01       Impact factor: 1.993

Review 5.  Overview of a novel sensor for continuous glucose monitoring.

Authors:  Günther Schmelzeisen-Redeker; Arnulf Staib; Monika Strasser; Ulrich Müller; Michael Schoemaker
Journal:  J Diabetes Sci Technol       Date:  2013-07-01

6.  Intravital microscopy evaluation of angiogenesis and its effects on glucose sensor performance.

Authors:  H E Koschwanez; W M Reichert; B Klitzman
Journal:  J Biomed Mater Res A       Date:  2010-06-15       Impact factor: 4.396

Review 7.  Intravital microscopy of tumor angiogenesis and regression in the dorsal skin fold chamber: mechanistic insights and preclinical testing of therapeutic strategies.

Authors:  Gudrun E Koehl; Andreas Gaumann; Edward K Geissler
Journal:  Clin Exp Metastasis       Date:  2009-02-04       Impact factor: 5.150

8.  Dorsal skinfold chamber models in mice.

Authors:  Jeannine Schreiter; Sophia Meyer; Christian Schmidt; Ronny M Schulz; Stefan Langer
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2017-07-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.