Literature DB >> 24113467

Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

J M Hoxworth1, D Lal, G P Fletcher, A C Patel, M He, R G Paden, A K Hara.   

Abstract

BACKGROUND AND
PURPOSE: CT performed with Veo model-based iterative reconstruction has shown the potential for radiation-dose reduction. This study sought to determine whether Veo could reduce noise and improve the image quality of low-dose sinus CT.
MATERIALS AND METHODS: Twenty patients consented to participate and underwent low- and standard-dose sinus CT on the same day. Standard-dose CT was created with filtered back-projection (120 kV[peak], 210 mA, 0.4-second rotation, and 0.531 pitch). For low-dose CT, mA was decreased to 20 (the remaining parameters were unchanged), and images were generated with filtered back-projection and Veo. Standard- and low-dose datasets were reconstructed by using bone and soft-tissue algorithms, while the low-dose Veo reconstruction only had a standard kernel. Two blinded neuroradiologists independently evaluated the image quality of multiple osseous and soft-tissue craniofacial structures. Image noise was measured by using multiple regions of interest.
RESULTS: Eight women and 12 men (mean age, 63.3 years) participated. Volume CT dose indices were 2.9 mGy (low dose) and 31.6 mGy (standard dose), and mean dose-length products were 37.4 mGy-cm (low dose) and 406.1 mGy-cm (standard dose). Of all the imaging series, low-dose Veo demonstrated the least noise (P < .001). Compared with filtered back-projection low-dose CT using soft-tissue and bone algorithms, Veo had the best soft-tissue image quality but the poorest bone image quality (P < .001).
CONCLUSIONS: Veo significantly reduces noise in low-dose sinus CT. Although this reduction improves soft-tissue evaluation, thin bone becomes less distinct.

Entities:  

Mesh:

Year:  2013        PMID: 24113467      PMCID: PMC7965812          DOI: 10.3174/ajnr.A3749

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  22 in total

Review 1.  Iterative reconstruction methods in X-ray CT.

Authors:  Marcel Beister; Daniel Kolditz; Willi A Kalender
Journal:  Phys Med       Date:  2012-02-10       Impact factor: 2.685

2.  Low-dose computed tomography of the paranasal sinus and facial skull using a high-pitch dual-source system--first clinical results.

Authors:  Boris Schell; Ralf W Bauer; Thomas Lehnert; J Matthias Kerl; Markus Hambek; Angelika May; Thomas J Vogl; Martin G Mack
Journal:  Eur Radiol       Date:  2010-07-20       Impact factor: 5.315

3.  Variability of radiation exposure with in-office sinus computed tomography examinations.

Authors:  Alexander E Stewart; John T Stalp; Cheryl Futerman; Winston C Vaughan
Journal:  Int Forum Allergy Rhinol       Date:  2011-04-28       Impact factor: 3.858

4.  Paranasal sinuses: low-dose CT.

Authors:  G Marmolya; E J Wiesen; R Yagan; C D Haria; A C Shah
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

5.  Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: feasibility and image quality.

Authors:  Stefan Bulla; Philipp Blanke; Frederike Hassepass; Tobias Krauss; Jan Thorsten Winterer; Christine Breunig; Mathias Langer; Gregor Pache
Journal:  Eur J Radiol       Date:  2011-06-12       Impact factor: 3.528

6.  Performance of iterative image reconstruction in CT of the paranasal sinuses: a phantom study.

Authors:  B Schulz; M Beeres; B Bodelle; R Bauer; F Al-Butmeh; A Thalhammer; T J Vogl; J M Kerl
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-06       Impact factor: 3.825

7.  The effect of decreasing mAs on image quality and patient dose in sinus CT.

Authors:  S A Sohaib; P D Peppercorn; J A Horrocks; M H Keene; G S Kenyon; R H Reznek
Journal:  Br J Radiol       Date:  2001-02       Impact factor: 3.039

8.  Comparison between low-dose and standard-dose multidetector CT in patients with suspected chronic sinusitis.

Authors:  Denis Tack; Jacques Widelec; Viviane De Maertelaer; Jean-Marie Bailly; Christian Delcour; Pierre Alain Gevenois
Journal:  AJR Am J Roentgenol       Date:  2003-10       Impact factor: 3.959

9.  Low-dose CT and inflammatory disease of the paranasal sinuses.

Authors:  B Duvoisin; M Landry; L Chapuis; M Krayenbuhl; P Schnyder
Journal:  Neuroradiology       Date:  1991       Impact factor: 2.804

10.  A comparison between low-dose and standard-dose non-contrasted multidetector CT scanning of the paranasal sinuses.

Authors:  Sy Lam; Si Bux; G Kumar; Kh Ng; Af Hussain
Journal:  Biomed Imaging Interv J       Date:  2009-07-01
View more
  17 in total

1.  Reducing the dose of CT of the paranasal sinuses: potential of an iterative reconstruction algorithm.

Authors:  Lars-Arne Schaafs; Julian Lenk; Bernd Hamm; Stefan Markus Niehues
Journal:  Dentomaxillofac Radiol       Date:  2016-07-15       Impact factor: 2.419

2.  Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.

Authors:  Wolfgang Wuest; Matthias May; Marc Saake; Michael Brand; Michael Uder; Michael Lell
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

3.  Radiation dose reduction in parasinus CT by spectral shaping.

Authors:  Matthias S May; Michael Brand; Michael M Lell; Martin Sedlmair; Thomas Allmendinger; Michael Uder; Wolfgang Wuest
Journal:  Neuroradiology       Date:  2017-01-16       Impact factor: 2.804

4.  Accuracy of computer-aided design models of the jaws produced using ultra-low MDCT doses and ASIR and MBIR.

Authors:  Asma'a A Al-Ekrish; Sara A Alfadda; Wadea Ameen; Romed Hörmann; Wolfgang Puelacher; Gerlig Widmann
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-16       Impact factor: 2.924

5.  Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

Authors:  Gerlig Widmann; Reema Al-Shawaf; Peter Schullian; Ra'ed Al-Sadhan; Romed Hörmann; Asma'a A Al-Ekrish
Journal:  Eur Radiol       Date:  2016-09-21       Impact factor: 5.315

6.  Investigation of iterative image reconstruction in low-dose breast CT.

Authors:  Junguo Bian; Kai Yang; John M Boone; Xiao Han; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2014-05-01       Impact factor: 3.609

7.  Noninvasive allergic sinus congestion and resolution assessments using microcomputed tomography imaging.

Authors:  Julia Litvinov; Walter C Spear; Igor Patrikeev; Massoud Motamedi; Bill T Ameredes
Journal:  J Appl Physiol (1985)       Date:  2018-08-30

8.  Application of a full model-based iterative reconstruction (MBIR) in 80 kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients.

Authors:  Jihang Sun; Qifeng Zhang; Xiaomin Duan; Chengyue Zhang; Pengpeng Wang; Chenguang Jia; Yong Liu; Yun Peng
Journal:  Radiol Med       Date:  2017-10-10       Impact factor: 3.469

9.  Universal sinus computed tomography protocol for diagnostic imaging and intraoperative navigation.

Authors:  Joseph M Hoxworth; Devyani Lal
Journal:  Allergy Rhinol (Providence)       Date:  2015-01

Review 10.  Optimized imaging of the midface and orbits.

Authors:  Sönke Langner
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2015-12-22
View more