Literature DB >> 20643600

REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Junghoon Lee1, Christian Labat, Ameet K Jain, Danny Y Song, Everette Clif Burdette, Gabor Fichtinger, Jerry L Prince.   

Abstract

The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstruction (REDMAPS) that uses multiple X-ray fluoroscopy images obtained from different poses is proposed. The seed reconstruction problem is formulated as a combinatorial optimization problem, and REDMAPS finds a solution in a clinically acceptable amount of time using dimensionality reduction to create a smaller space of possible solutions. Dimensionality reduction is possible since the optimal solution has approximately zero cost when the poses of the acquired images are known to be within a small error. REDMAPS is also formulated to address the "hidden seed problem" in which seeds overlap on one or more observed images. REDMAPS uses a pruning algorithm to avoid unnecessary computation of cost metrics and the reduced problem is solved using linear programming. REDMAPS was first evaluated and its parameters tuned using simulations. It was then validated using five phantom and 21 patient datasets. REDMAPS was successful in reconstructing the seeds with an overall seed matching rate above 99% and a reconstruction error below 1 mm in less than 5 s.

Entities:  

Mesh:

Year:  2010        PMID: 20643600      PMCID: PMC3072797          DOI: 10.1109/TMI.2010.2059709

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  43 in total

1.  Real-time optimized intraoperative dosimetry for prostate brachytherapy: a pilot study.

Authors:  D C Beyer; R H Shapiro; F Puente
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-12-01       Impact factor: 7.038

2.  Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing.

Authors:  D Tubic; A Zaccarin; L Beaulieu; J Pouliot
Journal:  Med Phys       Date:  2001-11       Impact factor: 4.071

3.  Fast cross-projection algorithm for reconstruction of seeds in prostate brachytherapy.

Authors:  Sreeram Narayanan; Paul S Cho; Robert J Marks
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

4.  Brachytherapy seed localization using geometric and linear programming techniques.

Authors:  Vikas Singh; Lopamudra Mukherjee; Jinhui Xu; Kenneth R Hoffmann; Petru M Dinu; Matthew Podgorsak
Journal:  IEEE Trans Med Imaging       Date:  2007-09       Impact factor: 10.048

5.  Transient elevation of serum prostate-specific antigen following (125)I/(103)Pd brachytherapy for localized prostate cancer.

Authors:  W Cavanagh; J C Blasko; P D Grimm; J E Sylvester
Journal:  Semin Urol Oncol       Date:  2000-05

6.  Rapid, accurate, three-dimensional location of multiple sees in implant radiotherapy treatment planning.

Authors:  M D Altschuler; P A Findlay; R D Epperson
Journal:  Phys Med Biol       Date:  1983-11       Impact factor: 3.609

7.  An automatic seed identification technique for interstitial implants using three isocentric radiographs.

Authors:  M S Rosenthal; R Nath
Journal:  Med Phys       Date:  1983 Jul-Aug       Impact factor: 4.071

8.  A three-film technique for reconstruction of radioactive seed implants.

Authors:  H I Amols; I I Rosen
Journal:  Med Phys       Date:  1981 Mar-Apr       Impact factor: 4.071

9.  Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

Authors:  Irving D Kaplan; Paul Meskell; Nicklas E Oldenburg; Brian Saltzman; Gary P Kearney; Edward J Holupka
Journal:  Brachytherapy       Date:  2006 Jul-Sep       Impact factor: 2.362

10.  Intraoperative adaptive brachytherapy of iodine-125 prostate implants guided by C-arm cone-beam computed tomography-based dosimetry.

Authors:  Hendrik Westendorp; Carel J Hoekstra; Arie van't Riet; André W Minken; Jos J Immerzeel
Journal:  Brachytherapy       Date:  2007 Oct-Dec       Impact factor: 2.362

View more
  13 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  C-arm angle measurement with accelerometer for brachytherapy: an accuracy study.

Authors:  Thomas Wolff; Andras Lasso; Markus Eblenkamp; Erich Wintermantel; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-03       Impact factor: 2.924

3.  Segmentation of iodine brachytherapy implants in fluoroscopy.

Authors:  Eric Moult; Gabor Fichtinger; W James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-25       Impact factor: 2.924

4.  Intraoperative segmentation of iodine and palladium radioactive sources in C-arm images.

Authors:  Chiara Amat di San Filippo; Gabor Fichtinger; William James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-07       Impact factor: 2.924

5.  An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy.

Authors:  Nathanael Kuo; Ehsan Dehghan; Anton Deguet; Omar Y Mian; Yi Le; E Clif Burdette; Gabor Fichtinger; Jerry L Prince; Danny Y Song; Junghoon Lee
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  A deformable multimodal image registration using PET/CT and TRUS for intraoperative focal prostate brachytherapy.

Authors:  Sharmin Sultana; Daniel Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-08

7.  Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy.

Authors:  Nathanael Kuo; Anton Deguet; Danny Y Song; Everette C Burdette; Jerry L Prince; Junghoon Lee
Journal:  Med Eng Phys       Date:  2011-07-29       Impact factor: 2.242

8.  Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; Yi Le; E Clif Burdette; Danny Y Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

9.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

10.  Deformable registration of X-ray to MRI for post-implant dosimetry in prostate brachytherapy.

Authors:  Seyoun Park; Danny Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.