Literature DB >> 21992346

Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Ehsan Dehghan1, Mehdi Moradi, Xu Wen, Danny French, Julio Lobo, W James Morris, Septimiu E Salcudean, Gabor Fichtinger.   

Abstract

PURPOSE: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging.
METHODS: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets.
RESULTS: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm.
CONCLUSIONS: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

Entities:  

Mesh:

Year:  2011        PMID: 21992346      PMCID: PMC3189971          DOI: 10.1118/1.3633897

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  46 in total

1.  Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing.

Authors:  D Tubic; A Zaccarin; L Beaulieu; J Pouliot
Journal:  Med Phys       Date:  2001-11       Impact factor: 4.071

2.  Improving the use of vibro-acoustography for brachytherapy metal seed imaging: a feasibility study.

Authors:  Farid G Mitri; Philippe Trompette; Jean-Yves Chapelon
Journal:  IEEE Trans Med Imaging       Date:  2004-01       Impact factor: 10.048

3.  Rotational encoding of C-arm fluoroscope with tilt sensing accelerometer.

Authors:  Victor Grzeda; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

4.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

5.  Matching and reconstruction of brachytherapy seeds using the Hungarian algorithm (MARSHAL).

Authors:  Ameet Kumar Jain; Yu Zhou; Tabish Mustufa; E Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

6.  TRUS-fluoroscopy fusion for intraoperative prostate brachytherapy dosimetry.

Authors:  Yi Su; Brian J Davis; Michael G Herman; Richard A Robb
Journal:  Stud Health Technol Inform       Date:  2006

7.  C-arm tracking and reconstruction without an external tracker.

Authors:  Ameet Jain; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

8.  A three-film technique for reconstruction of radioactive seed implants.

Authors:  H I Amols; I I Rosen
Journal:  Med Phys       Date:  1981 Mar-Apr       Impact factor: 4.071

9.  Registration between ultrasound and fluoroscopy or CT in prostate brachytherapy.

Authors:  P Fallavollita; Z Karim Aghaloo; E C Burdette; D Y Song; P Abolmaesumi; G Fichtinger
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

10.  Evaluation of dosimetric parameters and disease response after 125 iodine transperineal brachytherapy for low- and intermediate-risk prostate cancer.

Authors:  W James Morris; Mira Keyes; David Palma; Michael McKenzie; Ingrid Spadinger; Alex Agranovich; Tom Pickles; Mitchell Liu; Winkle Kwan; Jonn Wu; Vince Lapointe; Eric Berthelet; Howard Pai; Robert Harrison; William Kwa; Joe Bucci; Violet Racz; Ryan Woods
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-11-25       Impact factor: 7.038

View more
  3 in total

1.  A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging.

Authors:  Shahram Amiri; David R Wilson; Bassam A Masri; Carolyn Anglin
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-10       Impact factor: 2.924

2.  C-arm angle measurement with accelerometer for brachytherapy: an accuracy study.

Authors:  Thomas Wolff; Andras Lasso; Markus Eblenkamp; Erich Wintermantel; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-03       Impact factor: 2.924

3.  Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; Yi Le; E Clif Burdette; Danny Y Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.