Literature DB >> 21772077

Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Junghoon Lee1, Nathanael Kuo, Anton Deguet, Ehsan Dehghan, Danny Y Song, Everette C Burdette, Jerry L Prince.   

Abstract

The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland, and the capability of intraoperatively localizing implanted seeds provides potential for dose evaluation and optimization during therapy. REDMAPS is a recently reported algorithm that carries out seed localization by detecting, matching and reconstructing seeds in only a few seconds from three acquired x-ray images (Lee et al 2011 IEEE Trans. Med. Imaging 29 38-51). In this paper, we present an automatic pose correction (APC) process that is combined with REDMAPS to allow for both more accurate seed reconstruction and the use of images with relatively large pose errors. APC uses a set of reconstructed seeds as a fiducial and corrects the image pose by minimizing the overall projection error. The seed matching and APC are iteratively computed until a stopping condition is met. Simulations and clinical studies show that APC significantly improves the reconstructions with an overall average matching rate of ⩾99.4%, reconstruction error of ⩽0.5 mm, and the matching solution optimality of ⩾99.8%.

Entities:  

Mesh:

Year:  2011        PMID: 21772077      PMCID: PMC3172706          DOI: 10.1088/0031-9155/56/15/022

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  43 in total

1.  Accurate assessment of patellar tracking using fiducial and intensity-based fluoroscopic techniques.

Authors:  T S Y Tang; N J MacIntyre; H S Gill; R A Fellows; N A Hill; D R Wilson; R E Ellis
Journal:  Med Image Anal       Date:  2004-09       Impact factor: 8.545

2.  FTRAC--a robust fluoroscope tracking fiducial.

Authors:  Ameet Kumar Jain; Tabish Mustafa; Yu Zhou; Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-10       Impact factor: 4.071

3.  On the question of 3D seed reconstruction in prostate brachytherapy: the determination of x-ray source and film locations.

Authors:  Mutian Zhang; Marco Zaider; Michael Worman; Gilad Cohen
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

4.  Matching and reconstruction of brachytherapy seeds using the Hungarian algorithm (MARSHAL).

Authors:  Ameet Kumar Jain; Yu Zhou; Tabish Mustufa; E Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

5.  Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds.

Authors:  M D Altschuler; A Kassaee
Journal:  Phys Med Biol       Date:  1997-02       Impact factor: 3.609

6.  Dose effects of seeds placement deviations from pre-planned positions in ultrasound guided prostate implants.

Authors:  J E Dawson; T Wu; T Roy; J Y Gu; H Kim
Journal:  Radiother Oncol       Date:  1994-09       Impact factor: 6.280

7.  A three-film technique for reconstruction of radioactive seed implants.

Authors:  H I Amols; I I Rosen
Journal:  Med Phys       Date:  1981 Mar-Apr       Impact factor: 4.071

8.  A survey of current clinical practice of permanent prostate brachytherapy in the United States.

Authors:  B R Prestidge; J J Prete; T A Buchholz; J L Friedland; R G Stock; P D Grimm; W S Bice
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-01-15       Impact factor: 7.038

9.  Examination of dosimetry accuracy as a function of seed detection rate in permanent prostate brachytherapy.

Authors:  Yi Su; Brian J Davis; Michael G Herman; Armando Manduca; Richard A Robb
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

10.  Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on post-implant dosimetry: an analysis based on serial CT acquisition.

Authors:  F M Waterman; N Yue; B W Corn; A P Dicker
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-07-15       Impact factor: 7.038

View more
  9 in total

1.  Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

Authors:  Guobin Zhang; Qiyuan Sun; Shan Jiang; Zhiyong Yang; Xiaodong Ma; Haisong Jiang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-22       Impact factor: 2.924

2.  An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy.

Authors:  Nathanael Kuo; Ehsan Dehghan; Anton Deguet; Omar Y Mian; Yi Le; E Clif Burdette; Gabor Fichtinger; Jerry L Prince; Danny Y Song; Junghoon Lee
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

3.  A deformable multimodal image registration using PET/CT and TRUS for intraoperative focal prostate brachytherapy.

Authors:  Sharmin Sultana; Daniel Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-08

4.  A Dynamic Dosimetry System for Prostate Brachytherapy.

Authors:  Nathanael Kuo; Ehsan Dehghan; Anton Deguet; Danny Y Song; Jerry L Prince; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-08

5.  Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Authors:  Ehsan Dehghan; Junghoon Lee; Pascal Fallavollita; Nathanael Kuo; Anton Deguet; Yi Le; E Clif Burdette; Danny Y Song; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2012-06-16       Impact factor: 8.545

6.  Intraoperative Registered Ultrasound and Fluoroscopy (iRUF) for dose calculation during prostate brachytherapy: Improved accuracy compared to standard ultrasound-based dosimetry.

Authors:  Junghoon Lee; Omar Y Mian; Yi Le; Hee Joon Bae; E Clif Burdette; Theodore L DeWeese; Jerry L Prince; Daniel Y Song
Journal:  Radiother Oncol       Date:  2017-06-21       Impact factor: 6.280

7.  Deformable registration of X-ray to MRI for post-implant dosimetry in prostate brachytherapy.

Authors:  Seyoun Park; Danny Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-18

8.  Deformable registration of PET/CT and ultrasound for disease-targeted focal prostate brachytherapy.

Authors:  Sharmin Sultana; Daniel Y Song; Junghoon Lee
Journal:  J Med Imaging (Bellingham)       Date:  2019-09-12

9.  Superior Postimplant Dosimetry Achieved Using Dynamic Intraoperative Dosimetry for Permanent Prostate Brachytherapy.

Authors:  Tanmay Singh; Junghoon Lee; Marianna Zahurak; Hee Joon Bae; Tamey Habtu; Robert Hobbs; Yi Le; Everette C Burdette; Daniel Y Song
Journal:  Pract Radiat Oncol       Date:  2021-03-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.