Literature DB >> 17896600

Brachytherapy seed localization using geometric and linear programming techniques.

Vikas Singh1, Lopamudra Mukherjee, Jinhui Xu, Kenneth R Hoffmann, Petru M Dinu, Matthew Podgorsak.   

Abstract

We propose an optimization algorithm to solve the brachytherapy seed localization problem in prostate brachytherapy. Our algorithm is based on novel geometric approaches to exploit the special structure of the problem and relies on a number of key observations which help us formulate the optimization problem as a minimization integer program (IP). Our IP model precisely defines the feasibility polyhedron for this problem using a polynomial number of half-spaces; the solution to its corresponding linear program is rounded to yield an integral solution to our task of determining correspondences between seeds in multiple projection images. The algorithm is efficient in theory as well as in practice and performs well on simulation data (approximately 98% accuracy) and real X-ray images (approximately 95% accuracy). We present in detail the underlying ideas and an extensive set of performance evaluations based on our implementation.

Mesh:

Year:  2007        PMID: 17896600     DOI: 10.1109/TMI.2007.900740

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

2.  Prostate brachytherapy seed localization with Gaussian blurring and camera self-calibration.

Authors:  Junghoon Lee; Xiaofeng Liu; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

3.  TOMOSYNTHESIS-BASED RADIOACTIVE SEED LOCALIZATION IN PROSTATE BRACHYTHERAPY USING MODIFIED DISTANCE MAP IMAGES.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Jerry L Prince; Gabor Fichtinger
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-05-14

4.  REDUCED-DIMENSIONALITY MATCHING FOR 3-D RECONSTRUCTION OF PROSTATE BRACHYTHERAPY IMPLANTS FROM INCOMPLETE DATA.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Gabor Fichtinger; Jerry L Prince
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-06-28

5.  Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm.

Authors:  A Jain; A Deguet; I Iordachita; G Chintalapani; S Vikal; J Blevins; Y Le; E Armour; C Burdette; D Song; G Fichtinger
Journal:  Med Image Anal       Date:  2010-08-14       Impact factor: 8.545

6.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

7.  Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Danny Y Song; Everette C Burdette; Jerry L Prince; Gabor Fichtinger
Journal:  IEEE Trans Med Imaging       Date:  2009-07-14       Impact factor: 10.048

8.  Prostate brachytherapy seed localization using a mobile c-arm without tracking.

Authors:  Maria S Ayad; Junghoon Lee; Jerry L Prince; Gabor Fichtinger
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-03-13
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.