Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

Irving D Kaplan1, Paul Meskell, Nicklas E Oldenburg, Brian Saltzman, Gary P Kearney, Edward J Holupka.   

Abstract

PURPOSE: Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. METHODS AND MATERIALS: Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT.
RESULTS: Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose.
CONCLUSION: Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.

Entities:  

Mesh:

Year:  2006        PMID: 16864065     DOI: 10.1016/j.brachy.2006.03.001

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  12 in total

1.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

2.  Automatic segmentation of radiographic fiducial and seeds from X-ray images in prostate brachytherapy.

Authors:  Nathanael Kuo; Anton Deguet; Danny Y Song; Everette C Burdette; Jerry L Prince; Junghoon Lee
Journal:  Med Eng Phys       Date:  2011-07-29       Impact factor: 2.242

3.  Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm.

Authors:  A Jain; A Deguet; I Iordachita; G Chintalapani; S Vikal; J Blevins; Y Le; E Armour; C Burdette; D Song; G Fichtinger
Journal:  Med Image Anal       Date:  2010-08-14       Impact factor: 8.545

4.  Intra-operative Localization of Brachytherapy Implants Using Intensity-based Registration.

Authors:  Z Karimaghaloo; P Abolmaesumi; N Ahmidi; T K Chen; D G Gobbi; G Fichtinger
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01

5.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

6.  Intraoperative Registered Ultrasound and Fluoroscopy (iRUF) for dose calculation during prostate brachytherapy: Improved accuracy compared to standard ultrasound-based dosimetry.

Authors:  Junghoon Lee; Omar Y Mian; Yi Le; Hee Joon Bae; E Clif Burdette; Theodore L DeWeese; Jerry L Prince; Daniel Y Song
Journal:  Radiother Oncol       Date:  2017-06-21       Impact factor: 6.280

7.  Model simulation and experimental validation of intratumoral chemotherapy using multiple polymer implants.

Authors:  Brent D Weinberg; Ravi B Patel; Hanping Wu; Elvin Blanco; Carlton C Barnett; Agata A Exner; Gerald M Saidel; Jinming Gao
Journal:  Med Biol Eng Comput       Date:  2008-06-04       Impact factor: 2.602

Review 8.  Imaging in radiation oncology: a perspective.

Authors:  Laura A Dawson; Cynthia Ménard
Journal:  Oncologist       Date:  2010

9.  Dosimetry of permanent interstitial prostate brachytherapy for an interoperative procedure, using O-arm based CT and TRUS.

Authors:  Hiromichi Ishiyama; Akane Sekiguchi; Takefumi Satoh; Hideyasu Tsumura; Kouji Takenaka; Shogo Kawakami; Ken-Ichi Tabata; Kentaro Kobayashi; Masatsugu Iwamura; Kazushige Hayakawa
Journal:  J Contemp Brachytherapy       Date:  2016-02-09

10.  Benefits of a dual sagittal crystal transducer for ultrasound imaging during I-125 seed implantation for permanent prostate brachytherapy.

Authors:  Emmie Kaljouw; Bradley Pieters; Kees Koedooder; Cees Lucas; Caro Koning
Journal:  J Contemp Brachytherapy       Date:  2012-09-29