Literature DB >> 22784870

Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

Ehsan Dehghan1, Junghoon Lee, Pascal Fallavollita, Nathanael Kuo, Anton Deguet, Yi Le, E Clif Burdette, Danny Y Song, Jerry L Prince, Gabor Fichtinger.   

Abstract

Prostate brachytherapy is a treatment for prostate cancer using radioactive seeds that are permanently implanted in the prostate. The treatment success depends on adequate coverage of the target gland with a therapeutic dose, while sparing the surrounding tissue. Since seed implantation is performed under transrectal ultrasound (TRUS) imaging, intraoperative localization of the seeds in ultrasound can provide physicians with dynamic dose assessment and plan modification. However, since all the seeds cannot be seen in the ultrasound images, registration between ultrasound and fluoroscopy is a practical solution for intraoperative dosimetry. In this manuscript, we introduce a new image-based nonrigid registration method that obviates the need for manual seed segmentation in TRUS images and compensates for the prostate displacement and deformation due to TRUS probe pressure. First, we filter the ultrasound images for subsequent registration using thresholding and Gaussian blurring. Second, a computationally efficient point-to-volume similarity metric, an affine transformation and an evolutionary optimizer are used in the registration loop. A phantom study showed final registration errors of 0.84 ± 0.45 mm compared to ground truth. In a study on data from 10 patients, the registration algorithm showed overall seed-to-seed errors of 1.7 ± 1.0 mm and 1.5 ± 0.9 mm for rigid and nonrigid registration methods, respectively, performed in approximately 30s per patient.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22784870      PMCID: PMC3448845          DOI: 10.1016/j.media.2012.06.001

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  46 in total

1.  Dynamic intraoperative dosimetry for prostate brachytherapy using a nonisocentric C-arm.

Authors:  Danny Y Song; Ameet K Jain; Zhe Zhang; Anton Deguet; Yi Le; Elwood Armour; E Clif Burdette; Gabor Fichtinger
Journal:  Brachytherapy       Date:  2010-08-09       Impact factor: 2.362

2.  Detection of brachytherapy seeds using 3-D transrectal ultrasound.

Authors:  Xu Wen; Septimiu Tim E Salcudean; Peter D Lawrence
Journal:  IEEE Trans Biomed Eng       Date:  2010-06-28       Impact factor: 4.538

3.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

Review 4.  Review of intraoperative imaging and planning techniques in permanent seed prostate brachytherapy.

Authors:  Alfredo Polo; Carl Salembier; Jack Venselaar; Peter Hoskin
Journal:  Radiother Oncol       Date:  2010-01-13       Impact factor: 6.280

5.  Clinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy.

Authors:  Malik Brunet-Benkhoucha; Frank Verhaegen; Stéphanie Lassalle; Dominic Béliveau-Nadeau; Brigitte Reniers; David Donath; Daniel Taussky; Jean-François Carrier
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

6.  AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: report of Task Group 137.

Authors:  Ravinder Nath; William S Bice; Wayne M Butler; Zhe Chen; Ali S Meigooni; Vrinda Narayana; Mark J Rivard; Yan Yu
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

7.  Cancer statistics, 2011: the impact of eliminating socioeconomic and racial disparities on premature cancer deaths.

Authors:  Rebecca Siegel; Elizabeth Ward; Otis Brawley; Ahmedin Jemal
Journal:  CA Cancer J Clin       Date:  2011-06-17       Impact factor: 508.702

8.  Brachytherapy seed reconstruction with joint-encoded C-arm single-axis rotation and motion compensation.

Authors:  Ehsan Dehghan; Ameet K Jain; Mehdi Moradi; Xu Wen; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Image Anal       Date:  2011-06-07       Impact factor: 8.545

9.  Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

Authors:  Junghoon Lee; Nathanael Kuo; Anton Deguet; Ehsan Dehghan; Danny Y Song; Everette C Burdette; Jerry L Prince
Journal:  Phys Med Biol       Date:  2011-07-19       Impact factor: 3.609

10.  Registration between ultrasound and fluoroscopy or CT in prostate brachytherapy.

Authors:  P Fallavollita; Z Karim Aghaloo; E C Burdette; D Y Song; P Abolmaesumi; G Fichtinger
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

View more
  9 in total

1.  Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

Authors:  Guobin Zhang; Qiyuan Sun; Shan Jiang; Zhiyong Yang; Xiaodong Ma; Haisong Jiang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-22       Impact factor: 2.924

2.  Intraoperative segmentation of iodine and palladium radioactive sources in C-arm images.

Authors:  Chiara Amat di San Filippo; Gabor Fichtinger; William James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-07       Impact factor: 2.924

3.  An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy.

Authors:  Nathanael Kuo; Ehsan Dehghan; Anton Deguet; Omar Y Mian; Yi Le; E Clif Burdette; Gabor Fichtinger; Jerry L Prince; Danny Y Song; Junghoon Lee
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

4.  A deformable multimodal image registration using PET/CT and TRUS for intraoperative focal prostate brachytherapy.

Authors:  Sharmin Sultana; Daniel Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2019-03-08

5.  A Dynamic Dosimetry System for Prostate Brachytherapy.

Authors:  Nathanael Kuo; Ehsan Dehghan; Anton Deguet; Danny Y Song; Jerry L Prince; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-08

6.  Intraoperative Registered Ultrasound and Fluoroscopy (iRUF) for dose calculation during prostate brachytherapy: Improved accuracy compared to standard ultrasound-based dosimetry.

Authors:  Junghoon Lee; Omar Y Mian; Yi Le; Hee Joon Bae; E Clif Burdette; Theodore L DeWeese; Jerry L Prince; Daniel Y Song
Journal:  Radiother Oncol       Date:  2017-06-21       Impact factor: 6.280

7.  CT AND MRI FUSION FOR POSTIMPLANT PROSTATE BRACHYTHERAPY EVALUATION.

Authors:  Ehsan Dehghan; Yi Le; Junghoon Lee; Daniel Y Song; Gabor Fichtinger; Jerry L Prince
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2016-06-16

8.  Deformable registration of X-ray to MRI for post-implant dosimetry in prostate brachytherapy.

Authors:  Seyoun Park; Danny Y Song; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-18

9.  Superior Postimplant Dosimetry Achieved Using Dynamic Intraoperative Dosimetry for Permanent Prostate Brachytherapy.

Authors:  Tanmay Singh; Junghoon Lee; Marianna Zahurak; Hee Joon Bae; Tamey Habtu; Robert Hobbs; Yi Le; Everette C Burdette; Daniel Y Song
Journal:  Pract Radiat Oncol       Date:  2021-03-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.