Literature DB >> 11764032

Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing.

D Tubic1, A Zaccarin, L Beaulieu, J Pouliot.   

Abstract

We present an algorithm, based on simulated annealing, for automatic seed matching and three-dimensional spatial coordinate reconstruction using either three radiographic films or three fluoroscopic images taken from different perspectives. The matching problem is defined in the framework of combinatorial optimization, which allows robust reconstruction in presence of calibration imprecision, patient movements, and isometric distortions. Furthermore, by using a global criterion to select the correct matching, we evade common problems of the three-film method and its variants in presence of noise. The algorithm has been tested on 112 clinical cases and 100 simulated implants and used clinically on more than 100 cases. Simulated implants were reconstructed with an average error of 0.21 mm. For clinical cases, comparison of the precision is performed between results obtained with this new method and results obtained using the three-film technique. Compared to the latter technique, the reconstruction precision was improved in 62% of the clinical cases.

Entities:  

Mesh:

Year:  2001        PMID: 11764032     DOI: 10.1118/1.1414309

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

Authors:  Junghoon Lee; Christian Labat; Ameet K Jain; Danny Y Song; Everette Clif Burdette; Gabor Fichtinger; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2010-07-19       Impact factor: 10.048

3.  Prostate brachytherapy seed localization with Gaussian blurring and camera self-calibration.

Authors:  Junghoon Lee; Xiaofeng Liu; Jerry L Prince; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

4.  TOMOSYNTHESIS-BASED RADIOACTIVE SEED LOCALIZATION IN PROSTATE BRACHYTHERAPY USING MODIFIED DISTANCE MAP IMAGES.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Jerry L Prince; Gabor Fichtinger
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-05-14

5.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

6.  Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

Authors:  Guobin Zhang; Qiyuan Sun; Shan Jiang; Zhiyong Yang; Xiaodong Ma; Haisong Jiang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-22       Impact factor: 2.924

7.  Segmentation of iodine brachytherapy implants in fluoroscopy.

Authors:  Eric Moult; Gabor Fichtinger; W James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-25       Impact factor: 2.924

8.  Intraoperative segmentation of iodine and palladium radioactive sources in C-arm images.

Authors:  Chiara Amat di San Filippo; Gabor Fichtinger; William James Morris; Septimiu E Salcudean; Ehsan Dehghan; Pascal Fallavollita
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-07       Impact factor: 2.924

9.  Intra-operative 3D guidance and edema detection in prostate brachytherapy using a non-isocentric C-arm.

Authors:  A Jain; A Deguet; I Iordachita; G Chintalapani; S Vikal; J Blevins; Y Le; E Armour; C Burdette; D Song; G Fichtinger
Journal:  Med Image Anal       Date:  2010-08-14       Impact factor: 8.545

10.  Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Danny Y Song; Everette C Burdette; Jerry L Prince; Gabor Fichtinger
Journal:  IEEE Trans Med Imaging       Date:  2009-07-14       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.