Literature DB >> 20544196

Cup loosening after cemented Metasul® total hip replacement: a retrieval analysis.

Christophe Nich1, Moussa Hamadouche.   

Abstract

Small-diameter cemented Metasul® cups have been previously identified to be at high risk of early loosening. We asked whether this particular mode of failure was associated with a specific histological feature. Periprosthetic tissues were obtained at the time of revision of two aseptically loose cemented Metasul® cups. Each tissue sample was processed for routine histological analysis. A slight metallosis was visible microscopically in all tissue samples. Metallic wear-debris particles were present both extracellularly and within the cytoplasm of macrophages. We noted a perivascular infiltration of lymphocytes accompanied by mature plasma cells. Our observations are compatible with the hypersensitivity-like reaction previously reported, described as an aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Although wear was within normal reported range limits, this tissue reaction appeared as a consequence of continuous release of metallic ions from the prosthetic articulation. We hypothesise that ALVAL was involved in acetabular component failure, although acetabular loosening may have been initiated by high mechanical stress.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20544196      PMCID: PMC3167397          DOI: 10.1007/s00264-010-1061-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  27 in total

1.  Functional results of hip arthroplasty with acrylic prosthesis.

Authors:  R M D'AUBIGNE; M POSTEL
Journal:  J Bone Joint Surg Am       Date:  1954-06       Impact factor: 5.284

2.  In vivo wear of three types of metal on metal hip prostheses during two decades of use.

Authors:  H McKellop; S H Park; R Chiesa; P Doorn; B Lu; P Normand; P Grigoris; H Amstutz
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

3.  Tissue reaction to metal on metal total hip prostheses.

Authors:  P F Doorn; J M Mirra; P A Campbell; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

4.  Experience with the Metasul total hip bearing system.

Authors:  B G Weber
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

5.  Tissue reactions to plastic and metallic wear products of joint endoprostheses.

Authors:  H G Willert; M Semlitsch
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

6.  Metal-on-metal articulation for artificial hip joints: laboratory study and clinical results.

Authors:  R M Streicher; M Semlitsch; R Schön; H Weber; C Rieker
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

7.  Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study.

Authors:  Moussa Hamadouche; Pierre Boutin; Jacques Daussange; Mark E Bolander; Laurent Sedel
Journal:  J Bone Joint Surg Am       Date:  2002-01       Impact factor: 5.284

8.  Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces.

Authors:  T P Schmalzried; P C Peters; B T Maurer; C R Bragdon; W H Harris
Journal:  J Arthroplasty       Date:  1996-04       Impact factor: 4.757

9.  Analysis of 118 second-generation metal-on-metal retrieved hip implants.

Authors:  H P Sieber; C B Rieker; P Köttig
Journal:  J Bone Joint Surg Br       Date:  1999-01

10.  Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement.

Authors:  Ian Holloway; William L Walter; Bernie Zicat; William K Walter
Journal:  Int Orthop       Date:  2008-11-05       Impact factor: 3.075

View more
  5 in total

1.  Aggressive granulomatosis of the hip: a forgotten mode of aseptic failure.

Authors:  Pablo Ariel Isidoro Slullitel; Rodrigo Brandariz; Jose Ignacio Oñativia; German Farfalli; Fernando Comba; Francisco Piccaluga; Martin Buttaro
Journal:  Int Orthop       Date:  2018-11-30       Impact factor: 3.075

2.  Cemented metal-on-metal total hip replacement with 28-mm head: prospective, long-term, clinical, radiological and metal ions data.

Authors:  Ibrahim A Malek; Sheethal Prasad Patange Subba Rao; Narendra Kumar Rath; U N Mallya
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-12-19

Review 3.  Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions?

Authors:  Patricia A Campbell; Michael S Kung; Andrew R Hsu; Joshua J Jacobs
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

4.  Is there any difference in survivorship of total hip arthroplasty with different bearing surfaces? A systematic review and network meta-analysis.

Authors:  Si Yin; Dangfeng Zhang; Hui Du; Heng Du; Zhanhai Yin; Yusheng Qiu
Journal:  Int J Clin Exp Med       Date:  2015-11-15

5.  Effect of Printing Parameters on Dimensional Error and Surface Roughness Obtained in Direct Ink Writing (DIW) Processes.

Authors:  Irene Buj-Corral; Alejandro Domínguez-Fernández; Ana Gómez-Gejo
Journal:  Materials (Basel)       Date:  2020-05-07       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.