Literature DB >> 10068001

Analysis of 118 second-generation metal-on-metal retrieved hip implants.

H P Sieber1, C B Rieker, P Köttig.   

Abstract

Osteolysis is due to particulate wear debris and is responsible for the long-term failure of total hip replacements. It has stimulated the development of alternative joint surfaces such as metal-on-metal or ceramic-on-ceramic implants. Since 1988 the second-generation metal-on-metal implant Metasul has been used in over 60 000 hips. Analysis of 118 retrieved specimens of the head or cup showed rates of wear of approximately 25 microm for the whole articulation per year in the first year, decreasing to about 5 microm per year after the third. Metal surfaces have a 'self-polishing' capacity. Scratches are worn out by further joint movement. Volumetric wear was decreased some 60-fold compared with that of metal-on-polyethylene implants, suggesting that second-generation metal-on-metal prostheses may considerably reduce osteolysis.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10068001     DOI: 10.1302/0301-620x.81b1.9047

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  46 in total

Review 1.  Recent Advances: Orthopaedics.

Authors:  C G Moran; L J Tourret
Journal:  BMJ       Date:  2001-04-14

2.  The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Harry McKellop; Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  A squeaky reputation: the problem may be design-dependent.

Authors:  Javad Parvizi; Bahar Adeli; Justin C Wong; Camilo Restrepo; Richard H Rothman
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  Assessment of wear on the cones of modular stainless steel Exeter hip stems.

Authors:  R P S Chaplin; A J C Lee; R M Hooper
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

5.  Cup loosening after cemented Metasul® total hip replacement: a retrieval analysis.

Authors:  Christophe Nich; Moussa Hamadouche
Journal:  Int Orthop       Date:  2010-06-11       Impact factor: 3.075

6.  Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

Authors:  Adolph V Lombardi; Michael D Skeels; Keith R Berend; Joanne B Adams; Orlando J Franchi
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

7.  Management of failed metal-on-metal total hip arthroplasty.

Authors:  Justin W Griffin; Michele D'Apuzzo; James A Browne
Journal:  World J Orthop       Date:  2012-06-18

8.  [Allergic reactions as differential diagnosis for periprosthetic infection].

Authors:  H Meyer; A Krüger; A Roessner; C H Lohmann
Journal:  Orthopade       Date:  2012-01       Impact factor: 1.087

9.  Perivascular lymphocytic infiltration is not limited to metal-on-metal bearings.

Authors:  Vincent Y Ng; Adolph V Lombardi; Keith R Berend; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

10.  Serum ion level after metal-on-metal THA in patients with renal failure.

Authors:  Chang Ich Hur; Taek Rim Yoon; Sang Gwon Cho; Eun Kyoo Song; Jong Keun Seon
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.