Literature DB >> 22042291

Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation.

Takushi Kawamorita1, Hiroshi Uozato, Kimiya Shimizu.   

Abstract

BACKGROUND: A modified implantable collamer lens (ICL) with a central hole (diameter, 0.36 mm), a "Hole-ICL", was created to improve aqueous humour circulation. The aim of this study was to investigate the fluid dynamic characteristics of aqueous humour in a Hole-ICL using computational fluid dynamics.
METHODS: Fluid dynamics simulation using an ICL was performed with thermal-hydraulic analysis software FloEFD V5 (Mentor Graphics Corp.). For the simulation, three-dimensional eye models based on a modified Liou-Brennan model eye with conventional ICL (Model ICM, STAAR SURGICAL) and a Hole-ICL were used. Both ICLs were -9.0 diopters (D) and 12.0 mm in length, with an optic of 5.5 mm. The vaulting was 0.50 mm. The quantity of aqueous humour produced by the ciliary body was set at 2.80 μl/min. Flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was also calculated, and trajectory analysis was performed.
RESULTS: The flow velocity 0.25 mm in front of the centre of the crystalline lens was 1.52 × 10(-1) mm/sec for the Hole-ICL and 1.21 × 10(-5) mm/sec for the conventional ICL. Outward flow from the hole in the Hole-ICL was confirmed by trajectory analysis.
CONCLUSION: These results suggest that Hole-ICLs improve the circulation of aqueous humour to the anterior surface of the crystalline lens.

Mesh:

Year:  2011        PMID: 22042291     DOI: 10.1007/s00417-011-1850-2

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  15 in total

1.  Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye.

Authors:  Kunitoshi Fujisawa; Kimiya Shimizu; Shigekazu Uga; Masanobu Suzuki; Koichi Nagano; Yuuki Murakami; Hiroko Goseki
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-04-25       Impact factor: 3.117

Review 2.  Phakic intraocular lenses.

Authors:  Carlo F Lovisolo; Dan Z Reinstein
Journal:  Surv Ophthalmol       Date:  2005 Nov-Dec       Impact factor: 6.048

3.  Posterior chamber myopia lenses in phakic eyes.

Authors:  P U Fechner; W Haigis; W Wichmann
Journal:  J Cataract Refract Surg       Date:  1996-03       Impact factor: 3.351

4.  Cataract development associated with collagen copolymer posterior chamber phakic intraocular lenses: clinicopathological correlation.

Authors:  Yousuf M Khalifa; Majid Moshirfar; Mark D Mifflin; Kandon Kamae; Nick Mamalis; Liliana Werner
Journal:  J Cataract Refract Surg       Date:  2010-10       Impact factor: 3.351

5.  Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients.

Authors:  Gerald Schmidinger; Birgit Lackner; Stefan Pieh; Christian Skorpik
Journal:  Ophthalmology       Date:  2010-04-03       Impact factor: 12.079

6.  Toric Implantable Collamer Lens for moderate to high myopic astigmatism.

Authors:  Donald R Sanders; David Schneider; Robert Martin; David Brown; David Dulaney; John Vukich; Stephen Slade; Steven Schallhorn
Journal:  Ophthalmology       Date:  2007-01       Impact factor: 12.079

7.  Vaulting of myopic and toric Implantable Collamer Lenses during accommodation measured with Visante optical coherence tomography.

Authors:  Are Lindland; Hilde Heger; Maria Kugelberg; Charlotta Zetterström
Journal:  Ophthalmology       Date:  2010-02-16       Impact factor: 12.079

8.  Crystalline lens changes in porcine eyes with implanted phakic IOL (ICL) with a central hole.

Authors:  Tetsu Shiratani; Kimiya Shimizu; Kunitoshi Fujisawa; Shigekazu Uga; Koichi Nagano; Yuuki Murakami
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-02-26       Impact factor: 3.117

9.  Metaanalysis of cataract development after phakic intraocular lens surgery.

Authors:  Li-Ju Chen; Yun-Jau Chang; Jonathan C Kuo; Rama Rajagopal; Dimitri T Azar
Journal:  J Cataract Refract Surg       Date:  2008-07       Impact factor: 3.351

10.  Incidence of lens opacities and clinically significant cataracts with the implantable contact lens: comparison of two lens designs.

Authors:  Donald R Sanders; John A Vukich
Journal:  J Refract Surg       Date:  2002 Nov-Dec       Impact factor: 3.573

View more
  17 in total

1.  A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport.

Authors:  Kyu-Yeon Hwang; Sung A Lim; So-Hyang Chung
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

2.  Theoretical study on the need for laser iridotomy in an implantable collamer lens with a hole using computational fluid dynamics.

Authors:  T Kawamorita; K Shimizu; N Shoji
Journal:  Eye (Lond)       Date:  2017-01-20       Impact factor: 3.775

3.  Phakic intraocular lenses.

Authors:  Imtiaz A Chaudhry; M Alaa El Danasoury
Journal:  Saudi J Ophthalmol       Date:  2013-10

4.  Effect of hole size on fluid dynamics of a posterior-chamber phakic intraocular lens with a central perforation by using computational fluid dynamics.

Authors:  Takushi Kawamorita; Kimiya Shimizu; Nobuyuki Shoji
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-19       Impact factor: 3.117

5.  A four-year observation of corneal densitometry after implantable collamer lens V4c implantation.

Authors:  Jing Zhao; Wen Yang; Jiao Zhao; Yang Shen; Ling Sun; Tian Han; Xiaoying Wang; Peijun Yao; Xingtao Zhou
Journal:  Ann Transl Med       Date:  2021-04

6.  Implantable collamer lens V4b and V4c for correction of high myopia.

Authors:  Vipul Bhandari; Smitha Karandikar; Jagdeesh K Reddy; Kirti Relekar
Journal:  J Curr Ophthalmol       Date:  2016-02-09

7.  Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic Astigmatism: Consort-Compliant Article.

Authors:  Kimiya Shimizu; Kazutaka Kamiya; Akihito Igarashi; Hidenaga Kobashi
Journal:  Medicine (Baltimore)       Date:  2016-04       Impact factor: 1.889

8.  Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c).

Authors:  Xun Chen; Huamao Miao; Rajeev Krishnan Naidu; Xiaoying Wang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-09-07       Impact factor: 2.209

9.  Comparison of intraocular pressure andvault after implantation of implantable collamer lens with and without a central hole.

Authors:  Haiting Chen; Guangzeng Niu; Yuxiang Fan; Jingxue Ma
Journal:  BMC Ophthalmol       Date:  2016-11-16       Impact factor: 2.209

10.  Implantable collamer lens with central hole: 3-year follow-up.

Authors:  Luis Fernández-Vega-Cueto; Carlos Lisa; José J Esteve-Taboada; Robert Montés-Micó; José F Alfonso
Journal:  Clin Ophthalmol       Date:  2018-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.