Literature DB >> 20299720

Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study.

Hans Bornefalk1, Mats Danielsson.   

Abstract

We show how the spectral imaging framework should be modified to account for a high fraction of Compton interactions in low Z detector materials such as silicon. Using this framework, where deposited energies differ from actual photon energies, we compare the performance of a silicon strip detector, including the influence of scatter inside the detector and charge sharing but disregarding signal pileup, with an ideal energy integrating detector. We show that although the detection efficiency for silicon rapidly drops for the acceleration voltages encountered in clinical computed tomography practice, silicon detectors could perform on a par with ideal energy integrating detectors for routine imaging tasks. The use of spectrally sensitive detectors opens up the possibility for decomposition techniques such as k-edge imaging, and we show that the proposed modification of the spectral imaging framework is beneficial for such imaging tasks.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20299720     DOI: 10.1088/0031-9155/55/7/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  33 in total

1.  Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: a feasibility study.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Phys Med Biol       Date:  2012-07-06       Impact factor: 3.609

2.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

3.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT.

Authors:  Jiulong Liu; Huanjun Ding; Sabee Molloi; Xiaoqun Zhang; Hao Gao
Journal:  IEEE Trans Med Imaging       Date:  2016-07-07       Impact factor: 10.048

4.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study.

Authors:  Mats Persson; Adam Wang; Norbert J Pelc
Journal:  J Med Imaging (Bellingham)       Date:  2020-07-17

5.  Measurement of breast tissue composition with dual energy cone-beam computed tomography: a postmortem study.

Authors:  Huanjun Ding; Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

Review 6.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

7.  The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

8.  Breast tissue characterization with photon-counting spectral CT imaging: a postmortem breast study.

Authors:  Huanjun Ding; Michael J Klopfer; Justin L Ducote; Fumitaro Masaki; Sabee Molloi
Journal:  Radiology       Date:  2014-05-07       Impact factor: 11.105

9.  Quantitative contrast-enhanced spectral mammography based on photon-counting detectors: A feasibility study.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Med Phys       Date:  2017-06-28       Impact factor: 4.071

10.  Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

Authors:  A Sisniega; W Zbijewski; J W Stayman; J Xu; K Taguchi; E Fredenberg; Mats Lundqvist; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-11-27       Impact factor: 3.609

View more