Literature DB >> 19626370

Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.

Guoyan Zheng1.   

Abstract

Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.

Entities:  

Mesh:

Year:  2009        PMID: 19626370      PMCID: PMC3046689          DOI: 10.1007/s10278-009-9226-4

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  22 in total

1.  Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching.

Authors:  Sorin Blendea; Kort Eckman; Branislav Jaramaz; Timothy J Levison; Anthony M Digioia
Journal:  Comput Aided Surg       Date:  2005-01

2.  Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography.

Authors:  Axel Marx; Marius von Knoch; Jörg Pförtner; Matthias Wiese; Guido Saxler
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-21       Impact factor: 3.067

Review 3.  Cup positioning in THA: current status and pitfalls. A systematic evaluation of the literature.

Authors:  J Beckmann; C Lüring; M Tingart; S Anders; J Grifka; F X Köck
Journal:  Arch Orthop Trauma Surg       Date:  2008-07-04       Impact factor: 3.067

4.  HipMatch: an object-oriented cross-platform program for accurate determination of cup orientation using 2D-3D registration of single standard X-ray radiograph and a CT volume.

Authors:  Guoyan Zheng; Xuan Zhang; Simon D Steppacher; Stephen B Murphy; Klaus A Siebenrock; Moritz Tannast
Journal:  Comput Methods Programs Biomed       Date:  2009-03-27       Impact factor: 5.428

5.  Accuracy considerations in navigated cup placement for total hip arthroplasty.

Authors:  U Langlotz; P A Grützner; K Bernsmann; J H Kowal; M Tannast; M Caversaccio; L-P Nolte
Journal:  Proc Inst Mech Eng H       Date:  2007-10       Impact factor: 1.617

6.  Validation of a new method for determination of cup orientation in THA.

Authors:  Simon D Steppacher; Moritz Tannast; Guoyan Zheng; Xuan Zhang; Jens Kowal; Suzanne E Anderson; Klaus A Siebenrock; Stephen B Murphy
Journal:  J Orthop Res       Date:  2009-12       Impact factor: 3.494

7.  Anatomic referencing of cup orientation in total hip arthroplasty.

Authors:  Moritz Tannast; Ulrich Langlotz; Klaus-Arno Siebenrock; Matthias Wiese; Kai Bernsmann; Frank Langlotz
Journal:  Clin Orthop Relat Res       Date:  2005-07       Impact factor: 4.176

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Dislocation after total hip arthroplasty. Causes and prevention.

Authors:  D E McCollum; W J Gray
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

10.  Dislocation following total hip replacement.

Authors:  M A Ali Khan; P H Brakenbury; I S Reynolds
Journal:  J Bone Joint Surg Br       Date:  1981
View more
  1 in total

1.  Computer assisted determination of acetabular cup orientation using 2D-3D image registration.

Authors:  Guoyan Zheng; Xuan Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-02-24       Impact factor: 2.924

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.