Literature DB >> 18666818

Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times.

Ming De Lin1, Greta Toncheva, Giao Nguyen, Sangroh Kim, Colin Anderson-Evans, G Allan Johnson, Terry T Yoshizumi.   

Abstract

Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies.

Entities:  

Mesh:

Year:  2008        PMID: 18666818      PMCID: PMC2533764          DOI: 10.1667/RR1328.1

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  12 in total

1.  AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology.

Authors:  C M Ma; C W Coffey; L A DeWerd; C Liu; R Nath; S M Seltzer; J P Seuntjens
Journal:  Med Phys       Date:  2001-06       Impact factor: 4.071

Review 2.  X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature.

Authors:  S D Shpilfoygel; R A Close; D J Valentino; G R Duckwiler
Journal:  Med Phys       Date:  2000-09       Impact factor: 4.071

3.  Optimized radiographic spectra for small animal digital subtraction angiography.

Authors:  Ming De Lin; Ehsan Samei; Cristian T Badea; Terry T Yoshizumi; G Allan Johnson
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

4.  Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry.

Authors:  Terry T Yoshizumi; Philip C Goodman; Donald P Frush; Giao Nguyen; Greta Toncheva; Maksudur Sarder; Lottie Barnes
Journal:  AJR Am J Roentgenol       Date:  2007-05       Impact factor: 3.959

5.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

6.  Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses.

Authors:  Kai Rothkamm; Markus Löbrich
Journal:  Proc Natl Acad Sci U S A       Date:  2003-04-04       Impact factor: 11.205

7.  A multiple image subtraction technique for enhancing low contrast, periodic objects.

Authors:  C A Mistretta; M G Ort; J R Cameron; A B Crummy; P R Moran
Journal:  Invest Radiol       Date:  1973 Jan-Feb       Impact factor: 6.016

8.  Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter.

Authors:  M Soubra; J Cygler; G Mackay
Journal:  Med Phys       Date:  1994-04       Impact factor: 4.071

9.  Commissioning and evaluation of a new commercial small rodent x-ray irradiator.

Authors:  Mk Woo; Ra Nordal
Journal:  Biomed Imaging Interv J       Date:  2006-01-01

Review 10.  Conventional and CT angiography in children: dosimetry and dose comparisons.

Authors:  Donald P Frush; Terry Yoshizumi
Journal:  Pediatr Radiol       Date:  2006-09
View more
  11 in total

1.  Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution.

Authors:  Cristian T Badea; Samuel M Johnston; Ergys Subashi; Yi Qi; Laurence W Hedlund; G Allan Johnson
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

2.  Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

Authors:  M Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

3.  Specific issues in small animal dosimetry and irradiator calibration.

Authors:  Terry Yoshizumi; Samuel L Brady; Mike E Robbins; J Daniel Bourland
Journal:  Int J Radiat Biol       Date:  2011-10       Impact factor: 2.694

4.  Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Authors:  Jeffrey R Ashton; Nicholas Befera; Darin Clark; Yi Qi; Lan Mao; Howard A Rockman; G Allan Johnson; Cristian T Badea
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

5.  Development and dosimetry of a small animal lung irradiation platform.

Authors:  Ross McGurk; Caroline Hadley; Isabel L Jackson; Zeljko Vujaskovic
Journal:  Health Phys       Date:  2012-10       Impact factor: 1.316

6.  The utility of micro-CT and MRI in the assessment of longitudinal growth of liver metastases in a preclinical model of colon carcinoma.

Authors:  Prachi Pandit; Samuel M Johnston; Yi Qi; Jennifer Story; Rendon Nelson; G Allan Johnson
Journal:  Acad Radiol       Date:  2013-04       Impact factor: 3.173

7.  Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators.

Authors:  Matthew D Belley; Chu Wang; Giao Nguyen; Rathnayaka Gunasingha; Nelson J Chao; Benny J Chen; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

8.  Comparison of 4D-microSPECT and microCT for murine cardiac function.

Authors:  Nicholas T Befera; Cristian T Badea; G Allan Johnson
Journal:  Mol Imaging Biol       Date:  2014-04       Impact factor: 3.488

9.  Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

Authors:  Essam H Mattar; Lina F Hammad; Huda I Al-Mohammed
Journal:  Med Sci Monit       Date:  2011-07

10.  Evaluation of clinical use of OneDose metal oxide semiconductor field-effect transistor detectors compared to thermoluminescent dosimeters to measure skin dose for adult patients with acute lymphoblastic leukemia.

Authors:  Huda Ibrahim Al-Mohammed
Journal:  N Am J Med Sci       Date:  2011-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.