Literature DB >> 24743496

Studies of a prototype linear stationary x-ray source for tomosynthesis imaging.

P R Schwoebel1, John M Boone, Joe Shao.   

Abstract

A prototype linear x-ray source to implement stationary source-stationary detector tomosynthesis (TS) imaging has been studied. Potential applications include human breast and small animal imaging. The source is comprised of ten x-ray source elements each consisting of a field emission cathode, electrostatic lens, and target. The electrostatic lens and target are common to all elements. The source elements form x-ray focal spots with minimum diameters of 0.3-0.4 mm at electron beam currents of up to 40 mA with a beam voltage of 40 kV. The x-ray flux versus time was quantified from each source. X-ray bremsstrahlung spectra from tungsten targets were produced using electron beam energies from 35 to 50 keV. The half-value layer was measured to be 0.8, 0.9, and 1.0 mm, respectively, for the 35, 40, and 45 kV tube potentials using the tungsten target. The suppression of voltage breakdown events, particularly during source operation, and the use of a modified form of the standard cold-cathode geometry, enhanced source reliability. The prototype linear source was used to collect tomographic data sets of a mouse phantom using digital TS reconstruction methods and demonstrated a slice-sensitivity profile with a full-width-half-maximum of 1.3 mm. Lastly, preliminary studies of tomographic imaging of flow through the mouse phantom were performed.

Entities:  

Mesh:

Year:  2014        PMID: 24743496      PMCID: PMC4083558          DOI: 10.1088/0031-9155/59/10/2393

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

Review 1.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research.

Authors:  M J Paulus; S S Gleason; S J Kennel; P R Hunsicker; D K Johnson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

2.  Digital tomosynthesis of the chest: utility for detection of lung metastasis in patients with colorectal cancer.

Authors:  H N Jung; M J Chung; J H Koo; H C Kim; K S Lee
Journal:  Clin Radiol       Date:  2011-09-21       Impact factor: 2.350

3.  Dose reduction in pediatric CT: a rational approach.

Authors:  John M Boone; Estella M Geraghty; J Anthony Seibert; Sandra L Wootton-Gorges
Journal:  Radiology       Date:  2003-08       Impact factor: 11.105

4.  Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: a truly hybrid x-ray/MR imaging system.

Authors:  R Fahrig; Z Wen; A Ganguly; G DeCrescenzo; J A Rowlands; G M Stevens; R F Saunders; N J Pelc
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

5.  A geometric calibration method for cone beam CT systems.

Authors:  Kai Yang; Alexander L C Kwan; DeWitt F Miller; John M Boone
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

6.  Stationary digital breast tomosynthesis with distributed field emission X-ray tube.

Authors:  F Sprenger; X Calderon; E Gidcumb; J Lu; X Qian; D Spronk; A Tucker; G Yang; O Zhou
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-03-03

7.  Comprehensive assessment of the slice sensitivity profiles in breast tomosynthesis and breast CT.

Authors:  Anita Nosratieh; Kai Yang; Shadi Aminololama-Shakeri; John M Boone
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

8.  A tetrahedron beam computed tomography benchtop system with a multiple pixel field emission x-ray tube.

Authors:  Xiaochao Xu; Joshua Kim; Philip Laganis; Derek Schulze; Yongguang Liang; Tiezhi Zhang
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

9.  The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis.

Authors:  Devon J Godfrey; H Page McAdams; James T Dobbins
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

10.  Monte Carlo simulation of a compact microbeam radiotherapy system based on carbon nanotube field emission technology.

Authors:  Eric C Schreiber; Sha X Chang
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.506

View more
  3 in total

1.  Multisource inverse-geometry CT. Part II. X-ray source design and prototype.

Authors:  V Bogdan Neculaes; Antonio Caiafa; Yang Cao; Bruno De Man; Peter M Edic; Kristopher Frutschy; Satish Gunturi; Lou Inzinna; Joseph Reynolds; Mark Vermilyea; David Wagner; Xi Zhang; Yun Zou; Norbert J Pelc; Brian Lounsberry
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

2.  Field-Induced Crystalline-to-Amorphous Phase Transformation on the Si Nano-Apex and the Achieving of Highly Reliable Si Nano-Cathodes.

Authors:  Yifeng Huang; Zexiang Deng; Weiliang Wang; Chaolun Liang; Juncong She; Shaozhi Deng; Ningsheng Xu
Journal:  Sci Rep       Date:  2015-05-21       Impact factor: 4.379

3.  Model evaluation of rapid 4-dimensional lung tomosynthesis.

Authors:  Joseph T Rakowski
Journal:  Adv Radiat Oncol       Date:  2018-03-08
  3 in total