Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study.

Kristina Hellén-Halme1.   

Abstract

This study evaluated the effect of two different tube voltages on clinicians' ability to diagnose approximal carious lesions in digital radiographs. One hundred extracted teeth were radiographed twice at two voltage settings, 60 and 70 kV, using a standardized procedure. Seven observers evaluated the radiographs on a standard color monitor pre-calibrated according to DICOM part 14. Evaluations were made at ambient light levels below 50 lx. All observations were analyzed with receiver operating characteristic curves. A histological examination of the teeth served as the criterion standard. A paired t test compared the effects of the two voltages. The significance level was set to p < 0.05. Weighted kappa statistics estimated intra-observer agreement. No significant difference in accuracy of approximal carious lesion diagnosis was found between the two voltage settings. But five observers rated dentin lesions on radiographs exposed at 70 kV better than on radiographs exposed at 60 kV. Intra-observer agreement differed from fair to moderate. There was no significant difference in accuracy of approximal carious lesion diagnosis between digital radiographs exposed with 60 or 70 kV.

Entities:  

Mesh:

Year:  2010        PMID: 20143243     DOI: 10.1007/s00784-010-0383-0

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  22 in total

Review 1.  The choice of gold standard for evaluating tests for caries diagnosis.

Authors:  A Wenzel; H Hintze
Journal:  Dentomaxillofac Radiol       Date:  1999-05       Impact factor: 2.419

2.  Diagnostic outcome of methods frequently used for caries validation. A comparison of clinical examination, radiography and histology following hemisectioning and serial tooth sectioning.

Authors:  Hanne Hintze; Ann Wenzel
Journal:  Caries Res       Date:  2003 Mar-Apr       Impact factor: 4.056

Review 3.  A review of dentists' use of digital radiography and caries diagnosis with digital systems.

Authors:  A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2006-09       Impact factor: 2.419

4.  The effect of lighting conditions on caries interpretation with a laptop computer in a clinical setting.

Authors:  Mark J Kutcher; Sajitha Kalathingal; John B Ludlow; Murillo Abreu; Enrique Platin
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-06-19

5.  Digital radiography in general dental practice: a field study.

Authors:  K Hellén-Halme; M Nilsson; A Petersson
Journal:  Dentomaxillofac Radiol       Date:  2007-07       Impact factor: 2.419

6.  Effect of different background lighting conditions on diagnostic performance of digital and film images.

Authors:  R A Cederberg; N L Frederiksen; B W Benson; J D Shulman
Journal:  Dentomaxillofac Radiol       Date:  1998-09       Impact factor: 2.419

Review 7.  Digital radiography and caries diagnosis.

Authors:  A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  1998-01       Impact factor: 2.419

8.  Accuracy of radiographic caries diagnosis at different kilovoltages and two film speeds.

Authors:  B Svenson; H G Gröndahl; A Petersson; A Olving
Journal:  Swed Dent J       Date:  1985

9.  Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector.

Authors:  H Kitagawa; A G Farman
Journal:  Dentomaxillofac Radiol       Date:  2004-01       Impact factor: 2.419

10.  Effect of monitors on approximal caries detection in digital radiographs--standard versus precalibrated DICOM part 14 displays: an in vitro study.

Authors:  Kristina Hellén-Halme; Mats Nilsson; Arne Petersson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-02-06
View more
  3 in total

1.  Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

Authors:  Elif Sogur; B Güniz Baksı; Kaan Orhan; S Candan Paksoy; Salih Dogan; Yılmaz S Erdal; Ali Mert
Journal:  Clin Oral Investig       Date:  2010-09-14       Impact factor: 3.573

2.  Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies.

Authors:  L Schropp; N S Alyass; A Wenzel; A Stavropoulos
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

3.  The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging.

Authors:  Kristina Hellén-Halme; Mats Nilsson
Journal:  J Oral Maxillofac Res       Date:  2013-10-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.