Literature DB >> 9879219

Effect of different background lighting conditions on diagnostic performance of digital and film images.

R A Cederberg1, N L Frederiksen, B W Benson, J D Shulman.   

Abstract

OBJECTIVE: To compare the performance of a photostimulable phosphor (PSP) imaging system with radiographic film for the detection of approximal lesions under two background lighting conditions.
METHODS: Bitewing exposures were made of the extracted human teeth with artificial approximal lesions using D-speed and E-speed radiographic film and a PSP imaging plate. Eight dentists rated 12 approximal surfaces in each image on a 5-point scale. Images were viewed with overhead fluorescent room lighting on and off. ROC curves were generated for each image receptor and lighting condition. Repeated measures analysis of variance ANOVA tested differences between observers, lesion size, image receptor, lighting condition.
RESULTS: Mean ROC curve areas for D-speed film viewed in full ambient light scored highest (0.8030) followed by E-speed film using dark conditions (0.7386). The lowest mean curve area was found when PSP (enhanced mode) images were viewed in a dark room (0.6726). Significant differences were found between observers, lesion size, image receptor and image receptor-lesion size interaction. No significant difference was found with background lighting.
CONCLUSIONS: Background lighting does not appear to effect the ability to detect artificial approximal lesions.

Entities:  

Mesh:

Year:  1998        PMID: 9879219     DOI: 10.1038/sj/dmfr/4600377

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  10 in total

1.  Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images.

Authors:  C J Trapnell; W C Scarfe; J H Cook; A M Silvejra; F J Regennitter; B S Haskell
Journal:  J Digit Imaging       Date:  2000-02       Impact factor: 4.056

2.  Effect of room illuminance on monitor black level luminance and monitor calibration.

Authors:  K Chakrabarti; R V Kaczmarek; J A Thomas; A Romanyukha
Journal:  J Digit Imaging       Date:  2004-01-30       Impact factor: 4.056

3.  Effect of display type, DICOM calibration and room illuminance in bitewing radiographs.

Authors:  Soili Kallio-Pulkkinen; Sisko Huumonen; Marianne Haapea; Esa Liukkonen; Annina Sipola; Osmo Tervonen; Miika T Nieminen
Journal:  Dentomaxillofac Radiol       Date:  2015-08-03       Impact factor: 2.419

4.  Evaluation of low-contrast perceptibility in dental restorative materials under the influence of ambient light conditions.

Authors:  A D Cruz; I C Lobo; A L B Lemos; M F Aguiar
Journal:  Dentomaxillofac Radiol       Date:  2015-01-28       Impact factor: 2.419

5.  Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study.

Authors:  Kristina Hellén-Halme
Journal:  Clin Oral Investig       Date:  2010-02-09       Impact factor: 3.573

6.  The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging.

Authors:  Kristina Hellén-Halme; Mats Nilsson
Journal:  J Oral Maxillofac Res       Date:  2013-10-01

7.  A Subjective Assessment of Perceived Clarity of Indirect Digital Images and Processed Digital Images with Conventional Intra-oral Periapical Radiographs.

Authors:  Suchetha N Malleshi; Mahima V G; Anudeepa Raina; Karthikeya Patil
Journal:  J Clin Diagn Res       Date:  2013-08-01

8.  Influence of the display monitor on observer performance in detection of dental caries.

Authors:  Farzad Esmaeili; Esrafil Balaei; Firoz Pouralibaba; Farzaneh Kaviani; Atabak Kashefimehr
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2007-09-10

9.  Comparison of the delay in processing time and protective plastic cases in two phosphor plate systems.

Authors:  Ali Murat Aktan; Mehmet Ertuğrul Ciftçi; Faruk Akgünlü
Journal:  ScientificWorldJournal       Date:  2012-11-07

10.  Effects of Different Viewing Conditions on Radiographic Interpretation.

Authors:  Mahkameh Moshfeghi; Majid Shahbazian; Soodabeh Sadat Sajadi; Sepideh Sajadi; Hossein Ansari
Journal:  J Dent (Tehran)       Date:  2015-11
  10 in total