Literature DB >> 3859029

Accuracy of radiographic caries diagnosis at different kilovoltages and two film speeds.

B Svenson, H G Gröndahl, A Petersson, A Olving.   

Abstract

Different kilovoltages (50, 60, 70, 90) and two films differing in speed (Kodak Ultra-Speed and Ektaspeed) were examined with regard to the diagnostic accuracy at detection of dental caries. Ten observers graded the occurrence of caries in radiographs of extracted premolars and their findings were compared with the actual presence or absence of caries. The ROC-technique was used to evaluate the results using the area under the curve as a measure of diagnostic accuracy. A significant difference was found between kilovoltages with better diagnostic accuracy for the lower kilovoltages. No significant difference was found between the two types of film. Our results suggest that a kilovoltage of 60 offers a proper balance between absorbed radiation dose and diagnostic accuracy. The use of Kodak Ektaspeed offers a diagnostic accuracy similar to that of Kodak Ultra-Speed.

Mesh:

Year:  1985        PMID: 3859029

Source DB:  PubMed          Journal:  Swed Dent J        ISSN: 0347-9994


  8 in total

1.  Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

Authors:  Elif Sogur; B Güniz Baksı; Kaan Orhan; S Candan Paksoy; Salih Dogan; Yılmaz S Erdal; Ali Mert
Journal:  Clin Oral Investig       Date:  2010-09-14       Impact factor: 3.573

2.  Diagnostic accuracy of different imaging modalities in detection of proximal caries.

Authors:  B Senel; K Kamburoglu; O Uçok; S P Yüksel; T Ozen; H Avsever
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

3.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

4.  Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography.

Authors:  K Kamburoglu; E Kolsuz; S Murat; S Yüksel; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2012-09       Impact factor: 2.419

5.  Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study.

Authors:  Kristina Hellén-Halme
Journal:  Clin Oral Investig       Date:  2010-02-09       Impact factor: 3.573

6.  The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging.

Authors:  Kristina Hellén-Halme; Mats Nilsson
Journal:  J Oral Maxillofac Res       Date:  2013-10-01

Review 7.  Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.

Authors:  Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2021-03-04       Impact factor: 3.525

8.  Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography.

Authors:  Mohamed Khalifa Zayet; Yara Rabee Helaly; Salma Belal Eiid
Journal:  Imaging Sci Dent       Date:  2014-09-17
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.