Literature DB >> 20008993

Implementation of an automated respiratory amplitude gating technique for PET/CT: clinical evaluation.

Guoping Chang1, Tingting Chang, Tinsu Pan, John W Clark, Osama R Mawlawi.   

Abstract

UNLABELLED: Amplitude gating techniques have recently been shown to be better at suppressing respiratory motion artifacts than phase gating. However, most commercial PET/CT scanners are equipped with phase gating capabilities only. The objective of this article was to propose and evaluate using patient studies an automated respiratory amplitude gating technique that could be implemented on current whole-body PET/CT scanners. A primary design feature of the proposed technique is to automatically match the respiratory amplitude captured during the CT scan with a corresponding amplitude during the PET scan.
METHODS: The proposed amplitude gating technique consists of a CT scan, followed by a list-mode PET scan. The CT scan was acquired while the patient's respiratory motion was recorded by a monitoring device that determined the respiratory motion amplitude captured during the CT scan. A program was designed to inject triggers into the PET list stream whenever the patient's respiration crossed a preset amplitude range determined by the captured amplitude during CT. To implement this proposed amplitude gating technique in whole-body PET/CT, a PET-first protocol was necessary to minimize the respiratory baseline drift between the CT and PET scans. In this implementation, a regular PET scan was first acquired over the patient's whole body but excluding the bed position that covered the lesion of interest. The whole-body CT scan was then acquired, followed by a list-mode PET acquisition over the bed position that covered the area of interest (lesion). The proposed amplitude gating technique was tested using 13 patients with 21 lung or thoracic tumors.
RESULTS: In the patient studies, the gated images-when compared with the ungated images-showed statistically significant improvements, with an average 27% and 28% increase in maximum and mean standardized uptake value, respectively, for all lesions. Furthermore, the tumors in the gated images showed better contrast using visual inspection and line profiles.
CONCLUSION: The implementation of the proposed respiratory amplitude gating technique on current PET/CT scanners is feasible, and amplitude-matched CT and PET data can be automatically generated using our proposed procedures without requiring patients to hold their breath or increase their radiation exposure.

Entities:  

Mesh:

Year:  2009        PMID: 20008993      PMCID: PMC3963814          DOI: 10.2967/jnumed.109.068759

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  22 in total

1.  The CT motion quantitation of lung lesions and its impact on PET-measured SUVs.

Authors:  Yusuf E Erdi; Sadek A Nehmeh; Tinsu Pan; Alexander Pevsner; Kenneth E Rosenzweig; Gikas Mageras; Ellen D Yorke; Heiko Schoder; Wendy Hsiao; Olivia D Squire; Phil Vernon; Jonathan B Ashman; Hassan Mostafavi; Steven M Larson; John L Humm
Journal:  J Nucl Med       Date:  2004-08       Impact factor: 10.057

2.  Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results.

Authors:  Luc Boucher; Serge Rodrigue; Roger Lecomte; François Bénard
Journal:  J Nucl Med       Date:  2004-02       Impact factor: 10.057

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

4.  A motion-incorporated reconstruction method for gated PET studies.

Authors:  Feng Qiao; Tinsu Pan; John W Clark; Osama R Mawlawi
Journal:  Phys Med Biol       Date:  2006-07-20       Impact factor: 3.609

5.  Attenuation correction for a combined 3D PET/CT scanner.

Authors:  P E Kinahan; D W Townsend; T Beyer; D Sashin
Journal:  Med Phys       Date:  1998-10       Impact factor: 4.071

6.  NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes.

Authors:  Brad J Kemp; Chang Kim; John J Williams; Alexander Ganin; Val J Lowe
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

7.  Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods.

Authors:  Issam El Naqa; Daniel A Low; Jeffrey D Bradley; Milos Vicic; Joseph O Deasy
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

8.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

Review 9.  PET/CT in oncology: integration into clinical management of lymphoma, melanoma, and gastrointestinal malignancies.

Authors:  Heiko Schöder; Steven M Larson; Henry W D Yeung
Journal:  J Nucl Med       Date:  2004-01       Impact factor: 10.057

Review 10.  Positron emission tomography/computed tomography: protocol issues and options.

Authors:  Todd M Blodgett; Barry M McCook; Michael P Federle
Journal:  Semin Nucl Med       Date:  2006-04       Impact factor: 4.446

View more
  16 in total

1.  Design and performance of a respiratory amplitude gating device for PET/CT imaging.

Authors:  Guoping Chang; Tingting Chang; John W Clark; Osama R Mawlawi
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

2.  Prone position [18F]FDG PET/CT to reduce respiratory motion artefacts in the evaluation of lung nodules.

Authors:  Hyung Ju Lee; Hye Joo Son; Mijin Yun; Jung Won Moon; Yoo Na Kim; Ji Young Woo; Suk Hyun Lee
Journal:  Eur Radiol       Date:  2021-04-14       Impact factor: 5.315

3.  Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211.

Authors:  Mathieu Hatt; John A Lee; Charles R Schmidtlein; Issam El Naqa; Curtis Caldwell; Elisabetta De Bernardi; Wei Lu; Shiva Das; Xavier Geets; Vincent Gregoire; Robert Jeraj; Michael P MacManus; Osama R Mawlawi; Ursula Nestle; Andrei B Pugachev; Heiko Schöder; Tony Shepherd; Emiliano Spezi; Dimitris Visvikis; Habib Zaidi; Assen S Kirov
Journal:  Med Phys       Date:  2017-05-18       Impact factor: 4.071

4.  PET/CT-guided biopsy with respiratory motion correction.

Authors:  Ruoqiao Zhang; Dženan Zukić; Darrin W Byrd; Andinet Enquobahrie; Adam M Alessio; Kevin Cleary; Filip Banovac; Paul E Kinahan
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-09-11       Impact factor: 2.924

5.  Clinical respiratory motion correction software (reconstruct, register and averaged-RRA), for 18F-FDG-PET-CT: phantom validation, practical implications and patient evaluation.

Authors:  Anne-Charlotte Bouyeure-Petit; Mathieu Chastan; Agathe Edet-Sanson; Stephanie Becker; Sebastien Thureau; Estelle Houivet; Pierre Vera; Sebastien Hapdey
Journal:  Br J Radiol       Date:  2017-01-03       Impact factor: 3.039

6.  Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging.

Authors:  Guoping Chang; Tingting Chang; Tinsu Pan; John W Clark; Osama R Mawlawi
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

7.  Assessment of pulmonary melanoma metastases with 18F-FDG PET/CT: which PET-negative patients require additional tests for definitive staging?

Authors:  Marius E Mayerhoefer; Helmut Prosch; Christian J Herold; Michael Weber; Georgios Karanikas
Journal:  Eur Radiol       Date:  2012-06-01       Impact factor: 5.315

8.  Amplitude-based optimal respiratory gating in positron emission tomography in patients with primary lung cancer.

Authors:  Willem Grootjans; Lioe-Fee de Geus-Oei; Antoi P W Meeuwis; Charlotte S van der Vos; Martin Gotthardt; Wim J G Oyen; Eric P Visser
Journal:  Eur Radiol       Date:  2014-08-06       Impact factor: 5.315

9.  Application of partial volume effect correction and 4D PET in the quantification of FDG avid lung lesions.

Authors:  Ali Salavati; Samuel Borofsky; Teo K Boon-Keng; Sina Houshmand; Benjapa Khiewvan; Babak Saboury; Ion Codreanu; Drew A Torigian; Habib Zaidi; Abass Alavi
Journal:  Mol Imaging Biol       Date:  2015-02       Impact factor: 3.488

Review 10.  Respiratory-gated PET/CT for pulmonary lesion characterisation-promises and problems.

Authors:  Russell Frood; Garry McDermott; Andrew Scarsbrook
Journal:  Br J Radiol       Date:  2018-02-05       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.