Literature DB >> 16861780

A motion-incorporated reconstruction method for gated PET studies.

Feng Qiao1, Tinsu Pan, John W Clark, Osama R Mawlawi.   

Abstract

Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can incorporate motion information to generate a motion-free image with all acquired data. A computer simulation and a phantom study were conducted to test the performance of this approach. The computer simulation was based on a digital phantom that was continuously scaled during data acquisition. The phantom study, on the other hand, used two spheres in a tank of water, all of which were filled with (18)F water. One of the spheres was stationary while the other moved in a sinusoidal fashion to simulate tumour motion in the thorax. Data were acquired using both 4D CT and gated PET. Motion information was derived from the 4D CT images and then used in the 4D PET model. Both studies showed that this 4D PET model had a good motion-compensating capability. In the phantom study, this approach reduced quantification error of the radioactivity concentration by 95% when compared to a corresponding static acquisition, while signal-to-noise ratio was improved by 210% when compared to a corresponding gated image.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16861780     DOI: 10.1088/0031-9155/51/15/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  57 in total

1.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems.

Authors:  Nikolaos Dikaios; David Izquierdo-Garcia; Martin J Graves; Venkatesh Mani; Zahi A Fayad; Tim D Fryer
Journal:  Eur Radiol       Date:  2011-09-22       Impact factor: 5.315

2.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Design and performance of a respiratory amplitude gating device for PET/CT imaging.

Authors:  Guoping Chang; Tingting Chang; John W Clark; Osama R Mawlawi
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

4.  MRI-based nonrigid motion correction in simultaneous PET/MRI.

Authors:  Se Young Chun; Timothy G Reese; Jinsong Ouyang; Bastien Guerin; Ciprian Catana; Xuping Zhu; Nathaniel M Alpert; Georges El Fakhri
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

5.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-12       Impact factor: 9.236

6.  System matrix modelling of externally tracked motion.

Authors:  Arman Rahmim; Ju-Chieh Cheng; Katie Dinelle; Mikhail Shilov; W Paul Segars; Olivier G Rousset; Benjamin M W Tsui; Dean F Wong; Vesna Sossi
Journal:  Nucl Med Commun       Date:  2008-06       Impact factor: 1.690

7.  Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging.

Authors:  B Guérin; S Cho; S Y Chun; X Zhu; N M Alpert; G El Fakhri; T Reese; C Catana
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

8.  Respiratory motion correction for quantitative PET/CT using all detected events with internal-external motion correlation.

Authors:  Chi Liu; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

9.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

10.  Implementation of an automated respiratory amplitude gating technique for PET/CT: clinical evaluation.

Authors:  Guoping Chang; Tingting Chang; Tinsu Pan; John W Clark; Osama R Mawlawi
Journal:  J Nucl Med       Date:  2009-12-15       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.