Literature DB >> 10757601

Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version.

I Kawrakow1.   

Abstract

In this report a new EGS4 version, called EGSnrc to reflect the substantial changes made to the original code is reported, which incorporates a new any-angle multiple elastic scattering theory, an improved electron-step algorithm, a correct implementation of the fictitious cross section method for sampling distances between discrete interactions, a more accurate evaluation of energy loss, as well as an exact boundary crossing algorithm. It is demonstrated that EGSnrc allows for an artifact free Monte Carlo simulation of ion chamber response and backscattering, situations that have been considered in the past as the two of the most stringent tests of condensed history Monte Carlo codes. A detailed discussion of the effect of the various components of the condensed history simulation of electron transport on the simulated ion chamber response is given in the accompanying paper.

Mesh:

Year:  2000        PMID: 10757601     DOI: 10.1118/1.598917

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  96 in total

1.  Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.

Authors:  Lilie L W Wang; David Klein; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Four-dimensional dosimetry validation and study in lung radiotherapy using deformable image registration and Monte Carlo techniques.

Authors:  Tzung-Chi Huang; Ji-An Liang; Thomas Dilling; Tung-Hsin Wu; Geoffrey Zhang
Journal:  Radiat Oncol       Date:  2010-05-29       Impact factor: 3.481

3.  Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment.

Authors:  George X Ding; Yawei Zhang; Lei Ren
Journal:  Med Phys       Date:  2019-04-29       Impact factor: 4.071

4.  Initial development of goCMC: a GPU-oriented fast cross-platform Monte Carlo engine for carbon ion therapy.

Authors:  Nan Qin; Marco Pinto; Zhen Tian; Georgios Dedes; Arnold Pompos; Steve B Jiang; Katia Parodi; Xun Jia
Journal:  Phys Med Biol       Date:  2017-01-31       Impact factor: 3.609

5.  Monte Carlo simulation of large electron fields.

Authors:  Bruce A Faddegon; Joseph Perl; Makoto Asai
Journal:  Phys Med Biol       Date:  2008-02-21       Impact factor: 3.609

6.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

Authors:  Joao Seco; Greg C Sharp; Ziji Wu; David Gierga; Florian Buettner; Harald Paganetti
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

7.  Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

Authors:  D L Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

8.  Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies.

Authors:  Bruce A Faddegon; Makoto Asai; Joseph Perl; Carl Ross; Josep Sempau; Jane Tinslay; Francesc Salvat
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

9.  The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy.

Authors:  Bruce A Faddegon; Iwan Kawrakow; Yuri Kubyshin; Joseph Perl; Josep Sempau; Laszlo Urban
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

10.  Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck.

Authors:  Ryota Onizuka; Fujio Araki; Takeshi Ohno; Yuji Nakaguchi; Yudai Kai; Yuuki Tomiyama; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2016-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.