Impact of backscatter material thickness on the depth dose of orthovoltage irradiators for radiobiology research.

Quan Chen1, Janelle Molloy, Tadahide Izumi, Edmond Sterpin.   

Abstract

The orthovoltage x-ray energy frequently used in radiation research is prone to dosimetry errors due to insufficient backscatter conditions. In many radiobiology studies, especially for cell irradiations, precise dose calculation algorithms such as Convolution-Superposition or Monte Carlo are impractical and as such, less accurate hand calculation methods are used for dose estimation. These dose estimation methods typically assume full backscatter conditions. The purpose of this study is to demonstrate the magnitude of the dose error that results from insufficient backscatter, and to provide lookup tables to account this issue. The beam spectra of several widely used commercial systems (XRAD-225, XRAD-320, SARRP) were used in Monte Carlo (MC) simulations on a series of phantom setups to investigate the impact of varying backscatter conditions on dosimetry. The depth dose curves for different field sizes, water phantom thicknesses and beam qualities were generated. In addition, depth dependent backscatter factors for different field sizes and different beam qualities were calculated. It is demonstrated that as much as a 50% dose difference exists for different backscatter conditions at the beam qualities studied. The choice of cell dish size as well as other changes in the experiment setup can have more than 10% impact on the dose. The impact of backscatter is reduced with a decrease in field size. Further, the thickness needed to provide full backscatter can be approximated as being equal to the field size. It is imperative to ensure full backscatter conditions during system and dosimeter calibration, or to use the look-up table provided in this study.

Entities:  

Year:  2019        PMID: 30673636      PMCID: PMC9202343          DOI: 10.1088/1361-6560/ab0120

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   4.174


  28 in total

Review 1.  Monte Carlo modelling of external radiotherapy photon beams.

Authors:  Frank Verhaegen; Jan Seuntjens
Journal:  Phys Med Biol       Date:  2003-11-07       Impact factor: 3.609

2.  Image-guided radiation therapy: from concept to practice.

Authors:  David A Jaffray
Journal:  Semin Radiat Oncol       Date:  2007-10       Impact factor: 5.934

3.  The small-animal radiation research platform (SARRP): dosimetry of a focused lens system.

Authors:  Hua Deng; Christopher W Kennedy; Elwood Armour; Erik Tryggestad; Eric Ford; Todd McNutt; Licai Jiang; John Wong
Journal:  Phys Med Biol       Date:  2007-04-26       Impact factor: 3.609

4.  Development and validation of a treatment planning system for small animal radiotherapy: SmART-Plan.

Authors:  Stefan J van Hoof; Patrick V Granton; Frank Verhaegen
Journal:  Radiother Oncol       Date:  2013-10-31       Impact factor: 6.280

5.  An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements.

Authors:  J Kim; R Hill; E Claridge Mackonis; Z Kuncic
Journal:  Phys Med Biol       Date:  2010-01-14       Impact factor: 3.609

Review 6.  Radiation dose-volume effects in the spinal cord.

Authors:  John P Kirkpatrick; Albert J van der Kogel; Timothy E Schultheiss
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-01       Impact factor: 7.038

Review 7.  Small animal radiotherapy research platforms.

Authors:  Frank Verhaegen; Patrick Granton; Erik Tryggestad
Journal:  Phys Med Biol       Date:  2011-05-26       Impact factor: 3.609

8.  Extension of PENELOPE to protons: simulation of nuclear reactions and benchmark with Geant4.

Authors:  E Sterpin; J Sorriaux; S Vynckier
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

9.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities.

Authors:  John Wong; Elwood Armour; Peter Kazanzides; Iulian Iordachita; Erik Tryggestad; Hua Deng; Mohammad Matinfar; Christopher Kennedy; Zejian Liu; Timothy Chan; Owen Gray; Frank Verhaegen; Todd McNutt; Eric Ford; Theodore L DeWeese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

10.  Characterization of an orthovoltage biological irradiator used for radiobiological research.

Authors:  Rezvan Azimi; Parham Alaei; Emiliano Spezi; Susanta K Hui
Journal:  J Radiat Res       Date:  2015-02-17       Impact factor: 2.724

View more
  3 in total

1.  Development and Validation of a Clinically Relevant Workflow for MR-Guided Volumetric Arc Therapy in a Rabbit Model of Head and Neck Cancer.

Authors:  Eftekhar Rajab Bolookat; Harish Malhotra; Laurie J Rich; Sandra Sexton; Leslie Curtin; Joseph A Spernyak; Anurag K Singh; Mukund Seshadri
Journal:  Cancers (Basel)       Date:  2020-03-01       Impact factor: 6.639

2.  Targeting PI3K and AMPKα Signaling Alone or in Combination to Enhance Radiosensitivity of Triple Negative Breast Cancer.

Authors:  Jeremy Johnson; Zeta Chow; Dana Napier; Eun Lee; Heidi L Weiss; B Mark Evers; Piotr Rychahou
Journal:  Cells       Date:  2020-05-19       Impact factor: 6.600

3.  PI3K/mTOR Dual Inhibitor PF-04691502 Is a Schedule-Dependent Radiosensitizer for Gastroenteropancreatic Neuroendocrine Tumors.

Authors:  Zeta Chow; Jeremy Johnson; Aman Chauhan; Tadahide Izumi; Michael Cavnar; Heidi Weiss; Courtney M Townsend; Lowell Anthony; Carrigan Wasilchenko; Matthew L Melton; Jörg Schrader; B Mark Evers; Piotr Rychahou
Journal:  Cells       Date:  2021-05-20       Impact factor: 7.666

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.