Literature DB >> 7643786

BEAM: a Monte Carlo code to simulate radiotherapy treatment units.

D W Rogers1, B A Faddegon, G X Ding, C M Ma, J We, T R Mackie.   

Abstract

This paper describes BEAM, a general purpose Monte Carlo code to simulate the radiation beams from radiotherapy units including high-energy electron and photon beams, 60Co beams and orthovoltage units. The code handles a variety of elementary geometric entities which the user puts together as needed (jaws, applicators, stacked cones, mirrors, etc.), thus allowing simulation of a wide variety of accelerators. The code is not restricted to cylindrical symmetry. It incorporates a variety of powerful variance reduction techniques such as range rejection, bremsstrahlung splitting and forcing photon interactions. The code allows direct calculation of charge in the monitor ion chamber. It has the capability of keeping track of each particle's history and using this information to score separate dose components (e.g., to determine the dose from electrons scattering off the applicator). The paper presents a variety of calculated results to demonstrate the code's capabilities. The calculated dose distributions in a water phantom irradiated by electron beams from the NRC 35 MeV research accelerator, a Varian Clinac 2100C, a Philips SL75-20, an AECL Therac 20 and a Scanditronix MM50 are all shown to be in good agreement with measurements at the 2 to 3% level. Eighteen electron spectra from four different commercial accelerators are presented and various aspects of the electron beams from a Clinac 2100C are discussed. Timing requirements and selection of parameters for the Monte Carlo calculations are discussed.

Entities:  

Mesh:

Year:  1995        PMID: 7643786     DOI: 10.1118/1.597552

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  174 in total

1.  Dose verification of IMRT by use of a COMPASS transmission detector.

Authors:  Yuji Nakaguchi; Fujio Araki; Masato Maruyama; Shunji Saiga
Journal:  Radiol Phys Technol       Date:  2011-10-26

2.  Monte Carlo calculations of the replacement correction factor, P(repl), for cylindrical chamber cavities in clinical photon and electron beams.

Authors:  Fujio Araki
Journal:  Radiol Phys Technol       Date:  2012-04-22

3.  Optimization of dual electron multileaf collimator materials by use of EGSnrc.

Authors:  Samuel O Inyang; Alan C Chamberlain
Journal:  Radiol Phys Technol       Date:  2010-05-13

4.  Monte Carlo simulations of electron beams collimated with a dual electron multileaf collimator: a feasibility study.

Authors:  S O Inyang; A C Chamberlain
Journal:  Radiol Phys Technol       Date:  2009-07-04

5.  Four-dimensional dosimetry validation and study in lung radiotherapy using deformable image registration and Monte Carlo techniques.

Authors:  Tzung-Chi Huang; Ji-An Liang; Thomas Dilling; Tung-Hsin Wu; Geoffrey Zhang
Journal:  Radiat Oncol       Date:  2010-05-29       Impact factor: 3.481

6.  GATE: a simulation toolkit for PET and SPECT.

Authors:  S Jan; G Santin; D Strul; S Staelens; K Assié; D Autret; S Avner; R Barbier; M Bardiès; P M Bloomfield; D Brasse; V Breton; P Bruyndonckx; I Buvat; A F Chatziioannou; Y Choi; Y H Chung; C Comtat; D Donnarieix; L Ferrer; S J Glick; C J Groiselle; D Guez; P F Honore; S Kerhoas-Cavata; A S Kirov; V Kohli; M Koole; M Krieguer; D J van der Laan; F Lamare; G Largeron; C Lartizien; D Lazaro; M C Maas; L Maigne; F Mayet; F Melot; C Merheb; E Pennacchio; J Perez; U Pietrzyk; F R Rannou; M Rey; D R Schaart; C R Schmidtlein; L Simon; T Y Song; J M Vieira; D Visvikis; R Van de Walle; E Wieërs; C Morel
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

7.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

8.  Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment.

Authors:  George X Ding; Yawei Zhang; Lei Ren
Journal:  Med Phys       Date:  2019-04-29       Impact factor: 4.071

9.  Prediction of back-scatter radiations to a beam monitor chamber of medical linear accelerators by use of the digitized target-current-pulse analysis method.

Authors:  Yusuke Suzuki; Naoki Hayashi; Hideki Kato; Hiroshi Fukuma; Yasujiro Hirose; Makoto Kawano; Yoshio Nishii; Masaru Nakamura; Takashi Mukouyama
Journal:  Radiol Phys Technol       Date:  2012-10-25

10.  Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck.

Authors:  Ryota Onizuka; Fujio Araki; Takeshi Ohno; Yuji Nakaguchi; Yudai Kai; Yuuki Tomiyama; Kazunari Hioki
Journal:  Radiol Phys Technol       Date:  2016-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.