Literature DB >> 9434298

Orthovoltage radiation therapy treatment planning using Monte Carlo simulation: treatment of neuroendocrine carcinoma of the maxillary sinus.

W Gao1, D E Raeside.   

Abstract

Dose distributions that result from treating a patient with orthovoltage beams are best determined with a treatment planning system that uses the Monte Carlo method, and such systems are not readily available. In the present work, the Monte Carlo method was used to develop a computer code for determining absorbed dose distributions in orthovoltage radiation therapy. The code was used in planning treatment of a patient with a neuroendocrine carcinoma of the maxillary sinus. Two lateral high-energy photon beams supplemented by an anterior orthovoltage photon beam were utilized in the treatment plan. For the clinical case and radiation beams considered, a reasonably uniform dose distribution (+/- 10%) is achieved within the target volume, while the dose to the lens of each eye is 4-8% of the prescribed dose. Therefore, an orthovoltage photon beam, when properly filtered and optimally combined with megavoltage beams, can be effective in the treatment of cancers below the skin, providing that accurate treatment planning is carried out to establish with accuracy and precision the doses to critical structures.

Entities:  

Mesh:

Year:  1997        PMID: 9434298     DOI: 10.1088/0031-9155/42/12/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Effect of the bone heterogeneity on the dose prescription in orthovoltage radiotherapy: A Monte Carlo study.

Authors:  James C L Chow; Grigor N Grigorov
Journal:  Rep Pract Oncol Radiother       Date:  2011-11-15

2.  Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy.

Authors:  Magdalena Bazalova; Hu Zhou; Paul J Keall; Edward E Graves
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

3.  Effect of anode angle on photon beam spectra and depth dose characteristics for X-RAD320 orthovoltage unit.

Authors:  Asghar Mesbahi; Seyed-Salman Zakariaee
Journal:  Rep Pract Oncol Radiother       Date:  2013-01-16

4.  Effects of Hounsfield number conversion on CT based proton Monte Carlo dose calculations.

Authors:  Hongyu Jiang; Joao Seco; Harald Paganetti
Journal:  Med Phys       Date:  2007-04       Impact factor: 4.071

5.  Neuroendocrine carcinoma arising in a wound of the postoperative maxillary sinus.

Authors:  Takeshi Kusunoki; Katsuhisa Ikeda
Journal:  Clin Pract       Date:  2012-01-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.