Literature DB >> 17634657

K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.

E Roessl1, R Proksa.   

Abstract

After passage through matter, the energy spectrum of a polychromatic beam of x-rays contains valuable information about the elemental composition of the absorber. Conventional x-ray systems or x-ray computed tomography (CT) systems, equipped with scintillator detectors operated in the integrating mode, are largely insensitive to this type of spectral information, since the detector output is proportional to the energy fluence integrated over the whole spectrum. The main purpose of this paper is to investigate to which extent energy-sensitive photon counting devices, operated in the pulse-mode, are capable of revealing quantitative information about the elemental composition of the absorber. We focus on the detection of element-specific, K-edge discontinuities of the photo-electric cross-section. To be specific, we address the question of measuring and imaging the local density of a gadolinium-based contrast agent, in the framework of a generalized dual-energy pre-processing. Our results are very promising and seem to open up new possibilities for the imaging of the distribution of elements with a high atomic number Z in the human body using x-ray attenuation measurements. To demonstrate the usefulness of the detection and the appropriate processing of the spectral information, we present simulated images of an artherosclerotic coronary vessel filled with gadolinium-based contrast agent. While conventional systems, equipped with integrating detectors, often fail to differentiate between contrast filled lumen and artherosclerotic plaque, the use of an energy-selective detection system based on the counting of individual photons reveals a strong contrast between plaque and contrast agent.

Entities:  

Mesh:

Year:  2007        PMID: 17634657     DOI: 10.1088/0031-9155/52/15/020

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  127 in total

1.  Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.

Authors:  H-M Cho; H Ding; B P Ziemer; S Molloi
Journal:  Phys Med Biol       Date:  2014-11-04       Impact factor: 3.609

2.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

3.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors.

Authors:  Katsuyuki Taguchi; Eric C Frey; Xiaolan Wang; Jan S Iwanczyk; William C Barber
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Computed tomography in color: NanoK-enhanced spectral CT molecular imaging.

Authors:  Dipanjan Pan; Ewald Roessl; Jens-Peter Schlomka; Shelton D Caruthers; Angana Senpan; Mike J Scott; John S Allen; Huiying Zhang; Grace Hu; Patrick J Gaffney; Eric T Choi; Volker Rasche; Samuel A Wickline; Roland Proksa; Gregory M Lanza
Journal:  Angew Chem Int Ed Engl       Date:  2010-12-10       Impact factor: 15.336

5.  Spectral response model for a multibin photon-counting spectral computed tomography detector and its applications.

Authors:  Xuejin Liu; Mats Persson; Hans Bornefalk; Staffan Karlsson; Cheng Xu; Mats Danielsson; Ben Huber
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-11

6.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

7.  Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo.

Authors:  Salim Si-Mohamed; David P Cormode; Daniel Bar-Ness; Monica Sigovan; Pratap C Naha; Jean-Baptiste Langlois; Lara Chalabreysse; Philippe Coulon; Ira Blevis; Ewald Roessl; Klaus Erhard; Loic Boussel; Philippe Douek
Journal:  Nanoscale       Date:  2017-11-30       Impact factor: 7.790

8.  Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT.

Authors:  Qiaofeng Xu; Alex Sawatzky; Mark A Anastasio; Carsten O Schirra
Journal:  Phys Med Biol       Date:  2014-04-28       Impact factor: 3.609

9.  The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

10.  A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data.

Authors:  Taly Gilat Schmidt; Rina Foygel Barber; Emil Y Sidky
Journal:  IEEE Trans Med Imaging       Date:  2017-04-24       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.