Literature DB >> 19859949

Model-based blind estimation of kinetic parameters in dynamic contrast enhanced (DCE)-MRI.

Jacob U Fluckiger1, Matthias C Schabel, Edward V R Dibella.   

Abstract

A method to simultaneously estimate the arterial input function (AIF) and pharmacokinetic model parameters from dynamic contrast-enhanced (DCE)-MRI data was developed. This algorithm uses a parameterized functional form to model the AIF and k-means clustering to classify tissue time-concentration measurements into a set of characteristic curves. An iterative blind estimation algorithm alternately estimated parameters for the input function and the pharmacokinetic model. Computer simulations were used to investigate the algorithm's sensitivity to noise and initial estimates. In 12 patients with sarcomas, pharmacokinetic parameter estimates were compared with "truth" obtained from model regression using a measured AIF. When arterial voxels were included in the blind estimation algorithm, the resulting AIF was similar to the measured input function. The "true" K(trans) values in tumor regions were not significantly different than the estimated values, 0.99 +/- 0.41 and 0.86 +/- 0.40 min(-1), respectively, P = 0.27. "True" k(ep) values also matched closely, 0.70 +/- 0.24 and 0.65 +/- 0.25 min(-1), P = 0.08. When only tissue curves free of significant vascular contribution are used (v(p) < 0.05), the resulting AIF showed substantial delay and dispersion consistent with a more local AIF such as has been observed in dynamic susceptibility contrast imaging in the brain.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19859949      PMCID: PMC2884174          DOI: 10.1002/mrm.22101

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: a simulation study.

Authors:  Melanie Schmitt; Magalie Viallon; Manfred Thelen; Wolfgang G Schreiber
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

2.  Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging.

Authors:  Timothy J Carroll; Howard A Rowley; Victor M Haughton
Journal:  Radiology       Date:  2003-03-27       Impact factor: 11.105

3.  Estimation of kinetic parameters without input functions: analysis of three methods for multichannel blind identification.

Authors:  Dmitri Y Riabkov; Edward V R Di Bella
Journal:  IEEE Trans Biomed Eng       Date:  2002-11       Impact factor: 4.538

4.  A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study.

Authors:  D Feng; K P Wong; C M Wu; W C Siu
Journal:  IEEE Trans Inf Technol Biomed       Date:  1997-12

5.  Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data.

Authors:  Thomas E Yankeelov; Greg O Cron; Christina L Addison; Julia C Wallace; Ruth C Wilkins; Bruce A Pappas; Giles E Santyr; John C Gore
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

6.  Uncertainty in T(1) mapping using the variable flip angle method with two flip angles.

Authors:  Matthias C Schabel; Glen R Morrell
Journal:  Phys Med Biol       Date:  2008-12-05       Impact factor: 3.609

7.  Simultaneous estimation of physiological parameters and the input function--in vivo PET data.

Authors:  K P Wong; D Feng; S R Meikle; M J Fulham
Journal:  IEEE Trans Inf Technol Biomed       Date:  2001-03

8.  Feasibility of using limited-population-based arterial input function for pharmacokinetic modeling of osteosarcoma dynamic contrast-enhanced MRI data.

Authors:  Ya Wang; Wei Huang; David M Panicek; Lawrence H Schwartz; Jason A Koutcher
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

9.  Multiple reference tissue method for contrast agent arterial input function estimation.

Authors:  Cheng Yang; Gregory S Karczmar; Milica Medved; Walter M Stadler
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

10.  Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI.

Authors:  Hai-Ling Margaret Cheng
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

View more
  18 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.

Authors:  Luminita A Tudorica; Karen Y Oh; Nicole Roy; Mark D Kettler; Yiyi Chen; Stephanie L Hemmingson; Aneela Afzal; John W Grinstead; Gerhard Laub; Xin Li; Wei Huang
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

3.  Response-Derived Input Function Estimation for Dynamic Contrast-Enhanced MRI Demonstrated by Anti-DLL4 Treatment in a Murine U87 Xenograft Model.

Authors:  Matthew D Silva; Brittany Yerby; Jodi Moriguchi; Albert Gomez; H Toni Jun; Angela Coxon; Sharon E Ungersma
Journal:  Mol Imaging Biol       Date:  2017-10       Impact factor: 3.488

4.  Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI.

Authors:  Moran Artzi; Gilad Liberman; Guy Nadav; Faina Vitinshtein; Deborah T Blumenthal; Felix Bokstein; Orna Aizenstein; Dafna Ben Bashat
Journal:  Neuroradiology       Date:  2015-04-07       Impact factor: 2.804

5.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II. In vivo results.

Authors:  Matthias C Schabel; Edward V R DiBella; Randy L Jensen; Karen L Salzman
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

6.  Dynamic-contrast-enhanced-MRI with extravasating contrast reagent: rat cerebral glioma blood volume determination.

Authors:  Xin Li; William D Rooney; Csanád G Várallyay; Seymur Gahramanov; Leslie L Muldoon; James A Goodman; Ian J Tagge; Audrey H Selzer; Martin M Pike; Edward A Neuwelt; Charles S Springer
Journal:  J Magn Reson       Date:  2010-07-31       Impact factor: 2.229

7.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations.

Authors:  Matthias C Schabel; Jacob U Fluckiger; Edward V R DiBella
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

8.  Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

Authors:  Jacob U Fluckiger; Matthias C Schabel; Edward V R DiBella
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

9.  Direct estimation of tracer-kinetic parameter maps from highly undersampled brain dynamic contrast enhanced MRI.

Authors:  Yi Guo; Sajan Goud Lingala; Yinghua Zhu; R Marc Lebel; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2016-11-17       Impact factor: 4.668

10.  A linear algorithm of the reference region model for DCE-MRI is robust and relaxes requirements for temporal resolution.

Authors:  Julio Cárdenas-Rodríguez; Christine M Howison; Mark D Pagel
Journal:  Magn Reson Imaging       Date:  2012-12-08       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.