Literature DB >> 20674422

Dynamic-contrast-enhanced-MRI with extravasating contrast reagent: rat cerebral glioma blood volume determination.

Xin Li1, William D Rooney, Csanád G Várallyay, Seymur Gahramanov, Leslie L Muldoon, James A Goodman, Ian J Tagge, Audrey H Selzer, Martin M Pike, Edward A Neuwelt, Charles S Springer.   

Abstract

The accurate mapping of the tumor blood volume (TBV) fraction (vb) is a highly desired imaging biometric goal. It is commonly thought that achieving this is difficult, if not impossible, when small molecule contrast reagents (CRs) are used for the T1-weighted (Dynamic-Contrast-Enhanced) DCE-MRI technique. This is because angiogenic malignant tumor vessels allow facile CR extravasation. Here, a three-site equilibrium water exchange model is applied to DCE-MRI data from the cerebrally-implanted rat brain U87 glioma, a tumor exhibiting rapid CR extravasation. Analyses of segments of the (and the entire) DCE data time-course with this "shutter-speed" pharmacokinetic model, which admits finite water exchange kinetics, allow TBV estimation from the first-pass segment. Pairwise parameter determinances were tested with grid searches of 2D parametric error surfaces. Tumor blood volume (vb), as well as ve (the extracellular, extravascular space volume fraction), and Ktrans (a CR extravasation rate measure) parametric maps are presented. The role of the Patlak Plot in DCE-MRI is also considered.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20674422      PMCID: PMC2946221          DOI: 10.1016/j.jmr.2010.07.004

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  30 in total

1.  Evidence for shutter-speed variation in CR bolus-tracking studies of human pathology.

Authors:  Thomas E Yankeelov; William D Rooney; Wei Huang; Jonathan P Dyke; Xin Li; Alina Tudorica; Jing-Huei Lee; Jason A Koutcher; Charles S Springer
Journal:  NMR Biomed       Date:  2005-05       Impact factor: 4.044

2.  Shutter-speed analysis of contrast reagent bolus-tracking data: Preliminary observations in benign and malignant breast disease.

Authors:  Xin Li; Wei Huang; Thomas E Yankeelov; Alina Tudorica; William D Rooney; Charles S Springer
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

3.  A unified magnetic resonance imaging pharmacokinetic theory: intravascular and extracellular contrast reagents.

Authors:  Xin Li; William D Rooney; Charles S Springer
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

4.  Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo.

Authors:  William D Rooney; Glyn Johnson; Xin Li; Eric R Cohen; Seong-Gi Kim; Kamil Ugurbil; Charles S Springer
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

5.  Model selection in magnetic resonance imaging measurements of vascular permeability: Gadomer in a 9L model of rat cerebral tumor.

Authors:  James R Ewing; Stephen L Brown; Mei Lu; Swayamprava Panda; Guangliang Ding; Robert A Knight; Yue Cao; Quan Jiang; Tavarekere N Nagaraja; Jamie L Churchman; Joseph D Fenstermacher
Journal:  J Cereb Blood Flow Metab       Date:  2006-03       Impact factor: 6.200

Review 6.  Angiogenesis in brain tumours.

Authors:  Rakesh K Jain; Emmanuelle di Tomaso; Dan G Duda; Jay S Loeffler; A Gregory Sorensen; Tracy T Batchelor
Journal:  Nat Rev Neurosci       Date:  2007-08       Impact factor: 34.870

7.  Dynamic NMR effects in breast cancer dynamic-contrast-enhanced MRI.

Authors:  Xin Li; Wei Huang; Elizabeth A Morris; Luminita A Tudorica; Venkatraman E Seshan; William D Rooney; Ian Tagge; Ya Wang; Jingang Xu; Charles S Springer
Journal:  Proc Natl Acad Sci U S A       Date:  2008-11-13       Impact factor: 11.205

8.  The magnetic resonance shutter speed discriminates vascular properties of malignant and benign breast tumors in vivo.

Authors:  Wei Huang; Xin Li; Elizabeth A Morris; Luminita A Tudorica; Venkatraman E Seshan; William D Rooney; Ian Tagge; Ya Wang; Jingang Xu; Charles S Springer
Journal:  Proc Natl Acad Sci U S A       Date:  2008-11-12       Impact factor: 11.205

9.  Fast and quiet MRI using a swept radiofrequency.

Authors:  Djaudat Idiyatullin; Curt Corum; Jang-Yeon Park; Michael Garwood
Journal:  J Magn Reson       Date:  2006-06-19       Impact factor: 2.229

Review 10.  Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols.

Authors:  P S Tofts; G Brix; D L Buckley; J L Evelhoch; E Henderson; M V Knopp; H B Larsson; T Y Lee; N A Mayr; G J Parker; R E Port; J Taylor; R M Weisskoff
Journal:  J Magn Reson Imaging       Date:  1999-09       Impact factor: 4.813

View more
  34 in total

1.  The concordance of MRI and quantitative autoradiography estimates of the transvascular transfer rate constant of albumin in a rat brain tumor model.

Authors:  Ramesh Paudyal; James R Ewing; Tavarekere N Nagaraja; Hassan Bagher-Ebadian; Robert A Knight; Swayamprava Panda; Mei Lu; Karyn Ledbetter; Joseph D Fenstermacher
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

2.  Modeling of Look-Locker estimates of the magnetic resonance imaging estimate of longitudinal relaxation rate in tissue after contrast administration.

Authors:  Ramesh Paudyal; Hassan Bagher-Ebadian; Tavarekere N Nagaraja; Joseph D Fenstermacher; James R Ewing
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

3.  Correlation of volume transfer coefficient Ktrans with histopathologic grades of gliomas.

Authors:  Na Zhang; Lijuan Zhang; Bensheng Qiu; Li Meng; Xiaoyi Wang; Bob L Hou
Journal:  J Magn Reson Imaging       Date:  2012-05-11       Impact factor: 4.813

4.  Definition of K(trans) and FA thresholds for better assessment of experimental glioma using high-field MRI: a feasibility study.

Authors:  T Engelhorn; M A Schwarz; A Hess; L Budinsky; P Pitann; I Eyüpoglu; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-12-18       Impact factor: 3.649

Review 5.  Novel frontiers in ultra-structural and molecular MRI of the brain.

Authors:  Jeff H Duyn; Alan P Koretsky
Journal:  Curr Opin Neurol       Date:  2011-08       Impact factor: 5.710

6.  Improved perfusion MR imaging assessment of intracerebral tumor blood volume and antiangiogenic therapy efficacy in a rat model with ferumoxytol.

Authors:  Seymur Gahramanov; Leslie L Muldoon; Xin Li; Edward A Neuwelt
Journal:  Radiology       Date:  2011-09-21       Impact factor: 11.105

7.  Intratumor distribution and test-retest comparisons of physiological parameters quantified by dynamic contrast-enhanced MRI in rat U251 glioma.

Authors:  Madhava P Aryal; Tavarekere N Nagaraja; Stephen L Brown; Mei Lu; Hassan Bagher-Ebadian; Guangliang Ding; Swayamprava Panda; Kelly Keenan; Glauber Cabral; Tom Mikkelsen; James R Ewing
Journal:  NMR Biomed       Date:  2014-08-14       Impact factor: 4.044

8.  A comparison of individual and population-derived vascular input functions for quantitative DCE-MRI in rats.

Authors:  David A Hormuth; Jack T Skinner; Mark D Does; Thomas E Yankeelov
Journal:  Magn Reson Imaging       Date:  2014-01-07       Impact factor: 2.546

9.  Gaussian mixture model-based classification of dynamic contrast enhanced MRI data for identifying diverse tumor microenvironments: preliminary results.

Authors:  S H Han; E Ackerstaff; R Stoyanova; S Carlin; W Huang; J A Koutcher; J K Kim; G Cho; G Jang; H Cho
Journal:  NMR Biomed       Date:  2013-02-25       Impact factor: 4.044

10.  MRI assessment of experimental gliomas using 17.6 T.

Authors:  Marc A Schwarz; Mirko Pham; Xavier Helluy; Arnd Doerfler; Tobias Engelhorn
Journal:  Neuroradiology       Date:  2013-03-10       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.