Literature DB >> 12450362

Estimation of kinetic parameters without input functions: analysis of three methods for multichannel blind identification.

Dmitri Y Riabkov1, Edward V R Di Bella.   

Abstract

Compartment modeling of dynamic medical image data implies that the concentration of the tracer over time in a particular region of the organ of interest is well modeled as a convolution of the tissue response with the tracer concentration in the blood stream. The tissue response is different for different tissues while the blood input is assumed to be the same for different tissues. The kinetic parameters characterizing the tissue responses can be estimated by multichannel blind identification methods. These algorithms use the simultaneous measurements of concentration in separate regions of the organ; if the regions have different responses, the measurement of the blood input function may not be required. Three blind identification algorithms are analyzed here to assess their utility in medical imaging: eigenvector-based algorithm for multichannel blind deconvolution; cross relations; and iterative quadratic maximum-likelihood (IQML). Comparisons of accuracy with conventional (not blind) identification techniques where the blood input is known are made as well. Tissue responses corresponding to a physiological two-compartment model are primarily considered. The statistical accuracies of estimation for the three methods are evaluated and compared for multiple parameter sets. The results show that IQML gives more accurate estimates than the other two blind identification methods.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12450362     DOI: 10.1109/TBME.2002.804588

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  19 in total

1.  An input function estimation method for FDG-PET human brain studies.

Authors:  Hongbin Guo; Rosemary A Renaut; Kewei Chen
Journal:  Nucl Med Biol       Date:  2007-07       Impact factor: 2.408

2.  Incorporating the effects of transcytolemmal water exchange in a reference region model for DCE-MRI analysis: theory, simulations, and experimental results.

Authors:  Thomas E Yankeelov; Jeffrey J Luci; Laura M DeBusk; P Charles Lin; John C Gore
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

Review 3.  Image-derived input function for brain PET studies: many challenges and few opportunities.

Authors:  Paolo Zanotti-Fregonara; Kewei Chen; Jeih-San Liow; Masahiro Fujita; Robert B Innis
Journal:  J Cereb Blood Flow Metab       Date:  2011-08-03       Impact factor: 6.200

4.  Quantification of Positron Emission Tomography Data Using Simultaneous Estimation of the Input Function: Validation with Venous Blood and Replication of Clinical Studies.

Authors:  Elizabeth A Bartlett; Mala Ananth; Samantha Rossano; Mengru Zhang; Jie Yang; Shu-Fei Lin; Nabeel Nabulsi; Yiyun Huang; Francesca Zanderigo; Ramin V Parsey; Christine DeLorenzo
Journal:  Mol Imaging Biol       Date:  2019-10       Impact factor: 3.488

5.  Simultaneous estimation of input functions: an empirical study.

Authors:  R Todd Ogden; Francesca Zanderigo; Stephen Choy; J John Mann; Ramin V Parsey
Journal:  J Cereb Blood Flow Metab       Date:  2009-12-09       Impact factor: 6.200

6.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II. In vivo results.

Authors:  Matthias C Schabel; Edward V R DiBella; Randy L Jensen; Karen L Salzman
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

7.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations.

Authors:  Matthias C Schabel; Jacob U Fluckiger; Edward V R DiBella
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

8.  Robust and efficient pharmacokinetic parameter non-linear least squares estimation for dynamic contrast enhanced MRI of the prostate.

Authors:  Soudabeh Kargar; Eric A Borisch; Adam T Froemming; Akira Kawashima; Lance A Mynderse; Eric G Stinson; Joshua D Trzasko; Stephen J Riederer
Journal:  Magn Reson Imaging       Date:  2017-12-24       Impact factor: 2.546

9.  Improved derivation of input function in dynamic mouse [18F]FDG PET using bladder radioactivity kinetics.

Authors:  Koon-Pong Wong; Xiaoli Zhang; Sung-Cheng Huang
Journal:  Mol Imaging Biol       Date:  2013-08       Impact factor: 3.488

10.  Reproducibility assessment of a multiple reference tissue method for quantitative dynamic contrast enhanced-MRI analysis.

Authors:  Cheng Yang; Gregory S Karczmar; Milica Medved; Aytekin Oto; Marta Zamora; Walter M Stadler
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.