Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators.

Rebecca M Howell1, Stephen F Kry, Eric Burgett, Nolan E Hertel, David S Followill.   

Abstract

Neutrons are a by-product of high-energy x-ray radiation therapy (threshold for [gamma,n] reactions in high-Z material -7 MeV). Neutron production varies depending on photon beam energy as well as on the manufacturer of the accelerator. Neutron production from modern linear accelerators (linacs) has not been extensively compared, particularly in terms of the differences in the strategies that various manufacturers have used to implement multileaf collimators (MLCs) into their linac designs. However, such information is necessary to determine neutron dose equivalents for different linacs and to calculate vault shielding requirements. The purpose of the current study, therefore, was to measure the neutron spectra from the most up-to-date linacs from three manufacturers: Varian 21EX operating at 15, 18, and 20 MV, Siemens ONCOR operating at 15 and 18 MV, and Elekta Precise operating at 15 and 18 MV. Neutron production was measured by means of gold foil activation in Bonner spheres. Based on the measurements, the authors determined neutron spectra and calculated the average energy, total neutron fluence, ambient dose equivalent, and neutron source strength. The shapes of the neutron spectra did not change significantly between accelerators or even as a function of treatment energy. However, the neutron fluence, and therefore the ambient dose equivalent, did vary, increasing with increasing treatment energy. For a given nominal treatment energy, these values were always highest for the Varian linac. The current study thus offers medical physicists extensive information about the neutron production of MLC-equipped linacs currently in operation and provides them information vital for accurate comparison and prediction of neutron dose equivalents and calculation of vault shielding requirements.

Entities:  

Mesh:

Year:  2009        PMID: 19810475      PMCID: PMC2738742          DOI: 10.1118/1.3159300

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  MAXED, a computer code for maximum entropy deconvolution of multisphere neutron spectrometer data.

Authors:  M Reginatto; P Goldhagen
Journal:  Health Phys       Date:  1999-11       Impact factor: 1.316

2.  Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code.

Authors:  Daryoush Sheikh-Bagheri; D W O Rogers
Journal:  Med Phys       Date:  2002-03       Impact factor: 4.071

3.  Monte Carlo simulation of the photoneutron field in linac radiotherapy treatments with different collimation systems.

Authors:  A Zanini; E Durisi; F Fasolo; C Ongaro; L Visca; U Nastasi; K W Burn; G Scielzo; J O Adler; J R M Annand; G Rosner
Journal:  Phys Med Biol       Date:  2004-02-21       Impact factor: 3.609

4.  Commissioning of a medical accelerator photon beam Monte Carlo simulation using wide-field profiles.

Authors:  J Pena; L Franco; F Gómez; A Iglesias; R Lobato; J Mosquera; A Pazos; J Pardo; M Pombar; A Rodríguez; J Sendón
Journal:  Phys Med Biol       Date:  2004-11-07       Impact factor: 3.609

5.  Out-of-field photon and neutron dose equivalents from step-and-shoot intensity-modulated radiation therapy.

Authors:  Stephen F Kry; Mohammad Salehpour; David S Followill; Marilyn Stovall; Deborah A Kuban; R Allen White; Isaac I Rosen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

6.  Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.

Authors:  Omar Chibani; Chang-Ming Charlie Ma
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

7.  Neutron fluence and energy spectra around the Varian Clinac 2100C/2300C medical accelerator.

Authors:  K R Kase; X S Mao; W R Nelson; J C Liu; J H Kleck; M Elsalim
Journal:  Health Phys       Date:  1998-01       Impact factor: 1.316

Review 8.  Conversion coefficients for use in radiological protection against external radiation. Adopted by the ICRP and ICRU in September 1995.

Authors: 
Journal:  Ann ICRP       Date:  1996

9.  Energy spectra, sources, and shielding considerations for neutrons generated by a flattening filter-free Clinac.

Authors:  Stephen F Kry; Rebecca M Howell; Uwe Titt; Mohammad Salehpour; Radhe Mohan; Oleg N Vassiliev
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators.

Authors:  David S Followill; Marilyn S Stovall; Stephen F Kry; Geoffrey S Ibbott
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

View more
  12 in total

1.  Effects of tertiary MLC configuration on secondary neutron spectra from 18 MV x-ray beams for the Varian 21EX linear accelerator.

Authors:  Rebecca M Howell; Stephen F Kry; Eric Burgett; David Followill; Nolan E Hertel
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

2.  Secondary neutron spectrum from 250-MeV passively scattered proton therapy: measurement with an extended-range Bonner sphere system.

Authors:  Rebecca M Howell; E A Burgett
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

3.  Technical Note: Time-gating to medical linear accelerator pulses: Stray radiation detector.

Authors:  Muhammad Ramish Ashraf; Petr Bruza; Venkat Krishnaswamy; David J Gladstone; Brian W Pogue
Journal:  Med Phys       Date:  2018-12-14       Impact factor: 4.071

4.  Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.

Authors:  Hassan Ali Nedaie; Hoda Darestani; Nooshin Banaee; Negin Shagholi; Kheirollah Mohammadi; Arjang Shahvar; Esmaeel Bayat
Journal:  J Med Phys       Date:  2014-01

5.  A Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs.

Authors:  N Mohammadi; S H Miri-Hakimabad; L Rafat-Motavalli
Journal:  J Biomed Phys Eng       Date:  2014-12-15

6.  Dosimetric assessment of brass mesh bolus for postmastectomy photon radiotherapy.

Authors:  Ryan Manger; Adam Paxton; Laura Cerviño
Journal:  J Appl Clin Med Phys       Date:  2016-07-25       Impact factor: 2.102

7.  Breakthrough whole body energy-specific and tissue-specific photoneutron dosimetry by novel miniature neutron dosimeter/spectrometer.

Authors:  Mehdi Sohrabi; Morteza Ebrahimzadeh Torkamani
Journal:  Sci Rep       Date:  2021-10-15       Impact factor: 4.379

8.  Evaluation of equivalent dose from neutrons and activation products from a 15-MV X-ray LINAC.

Authors:  Isra Israngkul-Na-Ayuthaya; Sivalee Suriyapee; Phongpheath Pengvanich
Journal:  J Radiat Res       Date:  2015-08-11       Impact factor: 2.724

9.  Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

Authors:  Carlos E Cardenas; Paige L Nitsch; Rajat J Kudchadker; Rebecca M Howell; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

10.  Design and fabrication of a Nano-based neutron shield for fast neutrons from medical linear accelerators in radiation therapy.

Authors:  Younes Afkham; Asghar Mesbahi; Abdolali Alemi; Farhad Zolfagharpour; Nasrollah Jabbari
Journal:  Radiat Oncol       Date:  2020-05-11       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.