Literature DB >> 15990026

Out-of-field photon and neutron dose equivalents from step-and-shoot intensity-modulated radiation therapy.

Stephen F Kry1, Mohammad Salehpour, David S Followill, Marilyn Stovall, Deborah A Kuban, R Allen White, Isaac I Rosen.   

Abstract

PURPOSE: To measure the photon and neutron out-of-treatment-field dose equivalents to various organs from different treatment strategies (conventional vs. intensity-modulated radiation therapy [IMRT]) at different treatment energies and delivered by different accelerators. METHODS AND MATERIALS: Independent measurements were made of the photon and neutron out-of-field dose equivalents resulting from one conventional and six IMRT treatments for prostate cancer. The conventional treatment used an 18-MV beam from a Clinac 2100; the IMRT treatments used 6-MV, 10-MV, 15-MV, and 18-MV beams from a Varian Clinac 2100 accelerator and 6-MV and 15-MV beams from a Siemens Primus accelerator. Photon doses were measured with thermoluminescent dosimeters in a Rando phantom, and neutron fluence was measured with gold foils. Dose equivalents to the colon, liver, stomach, lung, esophagus, thyroid, and active bone marrow were determined for each treatment approach.
RESULTS: For each treatment approach, the relationship between dose equivalent per MU, distance from the treatment field, and depth in the patient was examined. Photon dose equivalents decreased approximately exponentially with distance from the treatment field. Neutron dose equivalents were independent of distance from the treatment field and decreased with increasing tissue depth. Neutrons were a significant contributor to the out-of field dose equivalent for beam energies > or =15 MV.
CONCLUSIONS: Out-of-field photon and neutron dose equivalents can be estimated to any point in a patient undergoing a similar treatment approach from the distance of that point to the central axis and from the tissue depth. This information is useful in determining the dose to critical structures and in evaluating the risk of associated carcinogenesis.

Entities:  

Mesh:

Year:  2005        PMID: 15990026     DOI: 10.1016/j.ijrobp.2004.12.091

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  50 in total

1.  Effect of photon-beam energy on VMAT and IMRT treatment plan quality and dosimetric accuracy for advanced prostate cancer.

Authors:  Marlies Pasler; Dietmar Georg; Holger Wirtz; Johannes Lutterbach
Journal:  Strahlenther Onkol       Date:  2011-11-29       Impact factor: 3.621

2.  Estimate of the uncertainties in the relative risk of secondary malignant neoplasms following proton therapy and intensity-modulated photon therapy.

Authors:  Jonas D Fontenot; Charles Bloch; David Followill; Uwe Titt; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

3.  Neutron spectra and dose equivalents calculated in tissue for high-energy radiation therapy.

Authors:  Stephen F Kry; Rebecca M Howell; Mohammad Salehpour; David S Followill
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

4.  A new analytical formula for neutron capture gamma dose calculations in double-bend mazes in radiation therapy.

Authors:  Hosein Ghiasi; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-24

5.  The effect of 6 and 15 MV on intensity-modulated radiation therapy prostate cancer treatment: plan evaluation, tumour control probability and normal tissue complication probability analysis, and the theoretical risk of secondary induced malignancies.

Authors:  M Hussein; S Aldridge; T Guerrero Urbano; A Nisbet
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

6.  Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators.

Authors:  Rebecca M Howell; Stephen F Kry; Eric Burgett; Nolan E Hertel; David S Followill
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

7.  EURADOS strategic research agenda: vision for dosimetry of ionising radiation.

Authors:  W Rühm; E Fantuzzi; R Harrison; H Schuhmacher; F Vanhavere; J Alves; J F Bottollier Depois; P Fattibene; Ž Knežević; M A Lopez; S Mayer; S Miljanić; S Neumaier; P Olko; H Stadtmann; R Tanner; C Woda
Journal:  Radiat Prot Dosimetry       Date:  2015-03-09       Impact factor: 0.972

8.  Thermal and resonance neutrons generated by various electron and X-ray therapeutic beams from medical linacs installed in polish oncological centers.

Authors:  Adam Konefał; Andrzej Orlef; Marcin Laciak; Aleksander Ciba; Marek Szewczuk
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-12

9.  Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.

Authors:  Bryan Bednarz; X George Xu
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

10.  Intensity-modulated radiation therapy (IMRT) vs. 3D conformal radiotherapy (3DCRT) in locally advanced rectal cancer (LARC): dosimetric comparison and clinical implications.

Authors:  Leire Arbea; Luis Isaac Ramos; Rafael Martínez-Monge; Marta Moreno; Javier Aristu
Journal:  Radiat Oncol       Date:  2010-02-26       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.