Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.

Omar Chibani1, Chang-Ming Charlie Ma.   

Abstract

The dose from photon-induced nuclear particles (neutrons, protons, and alpha particles) generated by high-energy photon beams from medical linacs is investigated. Monte Carlo calculations using the MCNPX code are performed for three different photon beams from two different machines: Siemens 18 MV, Varian 15 MV, and Varian 18 MV. The linac head components are simulated in detail. The dose distributions from photons, neutrons, protons, and alpha particles are calculated in a tissue-equivalent phantom. Neutrons are generated in both the linac head and the phantom. This study includes (a) field size effects, (b) off-axis dose profiles, (c) neutron contribution from the linac head, (d) dose contribution from capture gamma rays, (e) phantom heterogeneity effects, and (f) effects of primary electron energy shift. Results are presented in terms of absolute dose distributions and also in terms of DER (dose equivalent ratio). The DER is the maximum dose from the particle (neutron, proton, or alpha) divided by the maximum photon dose, multiplied by the particle quality factor and the modulation scaling factor. The total DER including neutrons, protons, and alphas is about 0.66 cSv/Gy for the Siemens 18 MV beam (10 cm x 10 cm). The neutron DER decreases with decreasing field size while the proton (or alpha) DER does not vary significantly except for the 1 cm x 1 cm field. Both Varian beams (15 and 18 MV) produce more neutrons, protons, and alphas particles than the Siemens 18 MV beam. This is mainly due to their higher primary electron energies: 15 and 18.3 MeV, respectively, vs 14 MeV for the Siemens 18 MV beam. For all beams, neutrons contribute more than 75% of the total DER, except for the 1 cm x 1 cm field (approximately 50%). The total DER is 1.52 and 2.86 cSv/Gy for the 15 and 18 MV Varian beams (10 cm x 10 cm), respectively. Media with relatively high-Z elements like bone may increase the dose from heavy charged particles by a factor 4. The total DER is sensitive to primary electron energy shift. A Siemens 18 MV beam with 15 MeV (instead of 14 MeV) primary electrons would increase by 40% the neutron DER and by 210% the proton + alpha DER. Comparisons with measurements (neutron yields from different materials and neutron dose equivalent) are also presented. Using the NCRP risk assessment method, we found that the dose equivalent from leakage neutrons (at 50-cm off-axis distance) represent 1.1, 1.1, and 2.0% likelihood of fatal secondary cancer for a 70 Gy treatment delivered by the Siemens 18 MV, Varian 15 MV, and Varian 18 MV beams, respectively.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12945965     DOI: 10.1118/1.1590436

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Nationwide survey on the operational status of electron accelerators for radiation therapy in Japan.

Authors:  Ichiro Yamaguchi; Shinji Tanaka; Toshioh Fujibuchi; Tetsuo Kida; Hiroaki Nagaoka; Hiroshi Watanabe
Journal:  Radiol Phys Technol       Date:  2010-01-22

2.  Dosimetric verification of the anisotropic analytical algorithm in lung equivalent heterogeneities with and without bone equivalent heterogeneities.

Authors:  Kaoru Ono; Satoru Endo; Kenichi Tanaka; Masaharu Hoshi; Yutaka Hirokawa
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  Neutron spectra and dose equivalents calculated in tissue for high-energy radiation therapy.

Authors:  Stephen F Kry; Rebecca M Howell; Mohammad Salehpour; David S Followill
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

Review 4.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

5.  A new analytical formula for neutron capture gamma dose calculations in double-bend mazes in radiation therapy.

Authors:  Hosein Ghiasi; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-24

6.  Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators.

Authors:  Rebecca M Howell; Stephen F Kry; Eric Burgett; Nolan E Hertel; David S Followill
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

Review 7.  Radiation-induced gliomas.

Authors:  Gautam Prasad; Daphne A Haas-Kogan
Journal:  Expert Rev Neurother       Date:  2009-10       Impact factor: 4.618

Review 8.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

9.  Monte Carlo calculation of photo-neutron dose produced by circular cones at 18 MV photon beams.

Authors:  Elham Hosseinzadeh; Nooshin Banaee; Hassan Ali Nedaie
Journal:  Rep Pract Oncol Radiother       Date:  2018-01-09

10.  Consideration of the radiation dose delivered away from the treatment field to patients in radiotherapy.

Authors:  Michael L Taylor; Tomas Kron
Journal:  J Med Phys       Date:  2011-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.