Literature DB >> 19789956

Radiation dose saving through the use of cone-beam CT in hearing-impaired patients.

N Faccioli1, M Barillari, S Guariglia, E Zivelonghi, A Rizzotti, R Cerini, R Pozzi Mucelli.   

Abstract

PURPOSE: Bionic ear implants provide a solution for deafness. Patients treated with these hearing devices are often children who require close follow-up with frequent functional and radiological examinations; in particular, multislice computed tomography (MSCT). Dental volumetric cone-beam CT (CBCT) has been reported as a reliable technique for acquiring images of the temporal bone while delivering low radiation doses and containing costs. The aim of this study was to assess, in terms of radiation dose and image quality, the possibility of using CBCT as an alternative to MSCT in patients with bionic ear implants.
MATERIALS AND METHODS: One hundred patients (mean age 26 years, range 7-43) with Vibrant SoundBridge implants on the round window underwent follow-up: 85 with CBCT and 15 with MSCT. We measured the average tissue-absorbed doses during both MSCT and CBCT scans. Each scan was focused on the temporal bone with the smallest field of view and a low-dose protocol. In order to estimate image quality, we obtained data about slice thickness, high- and low-contrast resolution, uniformity and noise by using an AAPM CT performance phantom.
RESULTS: Although the CBCT images were qualitatively inferior to those of MSCT, they were sufficiently diagnostic to allow evaluation of the position of the implants. The effective dose of MSCT was almost three times higher than that of CBCT.
CONCLUSIONS: Owing to low radiation dose and sufficient image quality, CBCT could be considered an adequate technique for postoperative imaging and follow-up of patients with bionic ear implants.

Entities:  

Mesh:

Year:  2009        PMID: 19789956     DOI: 10.1007/s11547-009-0462-y

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  22 in total

1.  Reference doses in dental radiodiagnostic facilities.

Authors:  L González; E Vañó; R Fernández
Journal:  Br J Radiol       Date:  2001-02       Impact factor: 3.039

2.  Radiation dose in dental radiology.

Authors:  M Cohnen; J Kemper; O Möbes; J Pawelzik; U Mödder
Journal:  Eur Radiol       Date:  2001-06-01       Impact factor: 5.315

3.  Comparison of patient dose from imaging protocols for dental implant planning using conventional radiography and computed tomography.

Authors:  A R Lecomber; Y Yoneyama; D J Lovelock; T Hosoi; A M Adams
Journal:  Dentomaxillofac Radiol       Date:  2001-09       Impact factor: 2.419

4.  Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit.

Authors:  J B Ludlow; L E Davies-Ludlow; S L Brooks
Journal:  Dentomaxillofac Radiol       Date:  2003-07       Impact factor: 2.419

5.  Dose reduction in maxillofacial imaging using low dose Cone Beam CT.

Authors:  Kostas Tsiklakis; Catherine Donta; Sophia Gavala; Kety Karayianni; Vasiliki Kamenopoulou; Costas J Hourdakis
Journal:  Eur J Radiol       Date:  2005-06-22       Impact factor: 3.528

6.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

7.  Accuracy of measurements of mandibular anatomy in cone beam computed tomography images.

Authors:  John B Ludlow; William Stewart Laster; Meit See; L'Tanya J Bailey; H Garland Hershey
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-08-04

8.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

9.  Must radiation dose for CT of the maxilla and mandible be higher than that for conventional panoramic radiography?

Authors:  C G Diederichs; W G Engelke; B Richter; K P Hermann; J W Oestmann
Journal:  AJNR Am J Neuroradiol       Date:  1996-10       Impact factor: 3.825

10.  Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window.

Authors:  Vittorio Colletti; Sigfrid D Soli; Marco Carner; L Colletti
Journal:  Int J Audiol       Date:  2006-10       Impact factor: 2.117

View more
  11 in total

Review 1.  Preoperative imaging assessment of chronic otitis media: what does the otologist need to know?

Authors:  A Stasolla; G Magliulo; A Cortese; A Roncacci; M Marini
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

Review 2.  Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review.

Authors:  A Al-Okshi; C Lindh; H Salé; M Gunnarsson; M Rohlin
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

3.  Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects.

Authors:  Ambrose J Huang; Connie Y Chang; Bijoy J Thomas; Peter J MacMahon; William E Palmer
Journal:  Skeletal Radiol       Date:  2015-02-05       Impact factor: 2.199

4.  Head and neck effective dose and quantitative assessment of image quality: a study to compare cone beam CT and multislice spiral CT.

Authors:  Cosimo Nardi; Cinzia Talamonti; Stefania Pallotta; Paola Saletti; Linda Calistri; Cesare Cordopatri; Stefano Colagrande
Journal:  Dentomaxillofac Radiol       Date:  2017-06-20       Impact factor: 2.419

Review 5.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

6.  [Visualization of subtle temporal bone structures. Comparison of cone beam CT and MDCT].

Authors:  M K Pein; S Brandt; S K Plontke; S Kösling
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

7.  Insertion characteristics and placement of the Mid-Scala electrode array in human temporal bones using detailed cone beam computed tomography.

Authors:  Aarno Dietz; Dzemal Gazibegovic; Jyrki Tervaniemi; Veli-Matti Vartiainen; Heikki Löppönen
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-05-19       Impact factor: 2.503

Review 8.  Active middle ear implantation: imaging in the pre-operative planning and post-operative assessment of the Vibrant SoundbridgeTM.

Authors:  Christian Burd; Irumee Pai; Steve Ej Connor
Journal:  Br J Radiol       Date:  2020-01-28       Impact factor: 3.039

9.  Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography.

Authors:  Niccolò Faccioli; Giovanni Foti; Marco Barillari; Andrea Atzei; Roberto Pozzi Mucelli
Journal:  Skeletal Radiol       Date:  2010-03-12       Impact factor: 2.199

10.  Congenital aural atresia treated with floating mass transducer on the round window: 5 years of imaging experience.

Authors:  M Barillari; R Cerini; M Carner; C Cacciatori; F Spagnolli; N Cardobi; M Mandalà; L Colletti; V Colletti; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2011-11-17       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.