Image quality and stability of image-guided radiotherapy (IGRT) devices: A comparative study.

Markus Stock1, Marlies Pasler, Wolfgang Birkfellner, Peter Homolka, Richard Poetter, Dietmar Georg.   

Abstract

INTRODUCTION: Our aim was to implement standards for quality assurance of IGRT devices used in our department and to compare their performances with that of a CT simulator.
MATERIALS AND METHODS: We investigated image quality parameters for three devices over a period of 16months. A multislice CT was used as a benchmark and results related to noise, spatial resolution, low contrast visibility (LCV) and uniformity were compared with a cone beam CT (CBCT) at a linac and simulator.
RESULTS: All devices performed well in terms of LCV and, in fact, exceeded vendor specifications. MTF was comparable between CT and linac CBCT. Integral nonuniformity was, on average, 0.002 for the CT and 0.006 for the linac CBCT. Uniformity, LCV and MTF varied depending on the protocols used for the linac CBCT. Contrast-to-noise ratio was an average of 51% higher for the CT than for the linac and simulator CBCT. No significant time trend was observed and tolerance limits were implemented. DISCUSSION: Reasonable differences in image quality between CT and CBCT were observed. Further research and development are necessary to increase image quality of commercially available CBCT devices in order for them to serve the needs for adaptive and/or online planning.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19695725      PMCID: PMC2867032          DOI: 10.1016/j.radonc.2009.07.012

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  20 in total

1.  A quality assurance program for the on-board imagers.

Authors:  Sua Yoo; Gwe-Ya Kim; Rabih Hammoud; Eric Elder; Todd Pawlicki; Huaiqun Guan; Timothy Fox; Gary Luxton; Fang-Fang Yin; Peter Munro
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

2.  A quantitative image quality comparison of four different image guided radiotherapy devices.

Authors:  Julia Stützel; Uwe Oelfke; Simeon Nill
Journal:  Radiother Oncol       Date:  2007-11-26       Impact factor: 6.280

Review 3.  Linac-integrated kV-cone beam CT: technical features and first applications.

Authors:  Uwe Oelfke; Thomas Tücking; Simeon Nill; Annete Seeber; Bernd Hesse; Peter Huber; Christoph Thilmann
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

4.  Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator.

Authors:  Cheng B Saw; Yong Yang; Fang Li; Ning J Yue; ChuXiong Ding; Krishna Komanduri; Saiful Huq; Dwight E Heron
Journal:  Med Dosim       Date:  2007       Impact factor: 1.482

5.  The influence of bowtie filtration on cone-beam CT image quality.

Authors:  N Mail; D J Moseley; J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Quality assurance of serial 3D image registration, fusion, and segmentation.

Authors:  Michael Sharpe; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008       Impact factor: 7.038

7.  Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.

Authors:  J R Sykes; R Lindsay; C J Dean; D S Brettle; D R Magee; D I Thwaites
Journal:  Phys Med Biol       Date:  2008-08-29       Impact factor: 3.609

8.  A quality assurance program for image quality of cone-beam CT guidance in radiation therapy.

Authors:  Jean-Pierre Bissonnette; Douglas J Moseley; David A Jaffray
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: first clinical results.

Authors:  Jasper Nijkamp; Floris J Pos; Tonnis T Nuver; Rianne de Jong; Peter Remeijer; Jan-Jakob Sonke; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-09-17       Impact factor: 7.038

10.  Commissioning experience with cone-beam computed tomography for image-guided radiation therapy.

Authors:  Joerg Lehmann; Julian Perks; Sheldon Semon; Rick Harse; James A Purdy
Journal:  J Appl Clin Med Phys       Date:  2007-07-17       Impact factor: 2.102

View more
  18 in total

1.  Assessment of accuracy and efficiency of atlas-based autosegmentation for prostate radiotherapy in a variety of clinical conditions.

Authors:  I Simmat; P Georg; D Georg; W Birkfellner; G Goldner; M Stock
Journal:  Strahlenther Onkol       Date:  2012-06-07       Impact factor: 3.621

2.  Validation of a deformable image registration technique for cone beam CT-based dose verification.

Authors:  M Moteabbed; G C Sharp; Y Wang; A Trofimov; J A Efstathiou; H-M Lu
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

3.  Evaluation of cone-beam computed tomography image quality assurance for Vero4DRT system.

Authors:  Hideharu Miura; Shuichi Ozawa; Masahiro Hayata; Shintarou Tsuda; Tsubasa Enosaki; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

4.  Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems.

Authors:  Stephen J Gardner; Matthew T Studenski; Tawfik Giaddui; Yunfeng Cui; James Galvin; Yan Yu; Ying Xiao
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

5.  Semi-automated IGRT QA using a cone-shaped scintillator screen detector for proton pencil beam scanning treatments.

Authors:  Weixing Cai; Hakan Oesten; Benjamin Clasie; Brian Winey; Kyung-Wook Jee
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

6.  Automated algorithm for CBCT-based dose calculations of prostate radiotherapy with bilateral hip prostheses.

Authors:  Turki Almatani; Richard P Hugtenburg; Ryan D Lewis; Susan E Barley; Mark A Edwards
Journal:  Br J Radiol       Date:  2016-07-27       Impact factor: 3.039

7.  Feasibility of offline head & neck adaptive radiotherapy using deformed planning CT electron density mapping on weekly cone beam computed tomography.

Authors:  Anantharaman Ayyalusamy; Subramani Vellaiyan; Subramanian Shanmugam; Arivarasan Ilamurugu; Arun Gandhi; Thirumalaiswamy Shanmugam; Kathirvel Murugesan
Journal:  Br J Radiol       Date:  2016-10-26       Impact factor: 3.039

8.  Improved cone-beam computed tomography in supine and prone breast radiotherapy. Surface reconstruction, radiation exposure, and clinical workflow.

Authors:  A De Puysseleyr; T Mulliez; A Gulyban; E Bogaert; T Vercauteren; T Van Hoof; J Van de Velde; R Van Den Broecke; C De Wagter; W De Neve
Journal:  Strahlenther Onkol       Date:  2013-10-03       Impact factor: 3.621

9.  The effect and stability of MVCT images on adaptive TomoTherapy.

Authors:  Poonam Yadav; Ranjini Tolakanahalli; Yi Rong; Bhudatt R Paliwal
Journal:  J Appl Clin Med Phys       Date:  2010-07-02       Impact factor: 2.102

10.  Comparison of CT number calibration techniques for CBCT-based dose calculation.

Authors:  Alex Dunlop; Dualta McQuaid; Simeon Nill; Julia Murray; Gavin Poludniowski; Vibeke N Hansen; Shreerang Bhide; Christopher Nutting; Kevin Harrington; Kate Newbold; Uwe Oelfke
Journal:  Strahlenther Onkol       Date:  2015-09-24       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.