Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator.

Cheng B Saw1, Yong Yang, Fang Li, Ning J Yue, ChuXiong Ding, Krishna Komanduri, Saiful Huq, Dwight E Heron.   

Abstract

A medical linear accelerator equipped with optical position tracking, ultrasound imaging, portal imaging, and radiographic imaging systems was installed at University of Pittsburgh Cancer Institute for the purpose of performing image-guided radiation therapy (IGRT) and image-guided radiosurgery (IGRS) in October 2005. We report the performance characteristics and quality assurance aspects of the kilovoltage cone-beam computed tomography (kV-CBCT) technique. This radiographic imaging system consists of a kilovoltage source and a large-area flat panel amorphous silicon detector mounted on the gantry of the medical linear accelerator via controlled arms. The performance characteristics and quality assurance aspects of this kV-CBCT technique involves alignment of the kilovoltage imaging system to the isocenter of the medical linear accelerator and assessment of (a) image contrast, (b) spatial accuracy of the images, (c) image uniformity, and (d) computed tomography (CT)-to-electron density conversion relationship were investigated. Using the image-guided tools, the alignment of the radiographic imaging system was assessed to be within a millimeter. The low-contrast resolution was found to be a 6-mm diameter hole at 1% contrast level and high-contrast resolution at 9 line pairs per centimeter. The spatial accuracy (50 mm +/- 1%), slice thickness (2.5 mm and 5.0 mm +/- 5%), and image uniformity (+/- 20 HU) were found to be within the manufacturer's specifications. The CT-to-electron density relationship was also determined. By using well-designed procedures and phantom, the number of parameter checks for quality assurance of the IGRT system can be carried out in a relatively short time.

Entities:  

Mesh:

Year:  2007        PMID: 17472886     DOI: 10.1016/j.meddos.2007.01.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  7 in total

1.  Prospective evaluation of spinal cord and cauda equina dose constraints using cone beam computed tomography (CBCT) image guidance for spine radiosurgery.

Authors:  Peter C Gerszten; Mubina Quader; Josef Novotny; John C Flickinger
Journal:  J Radiosurg SBRT       Date:  2011

2.  Image quality and stability of image-guided radiotherapy (IGRT) devices: A comparative study.

Authors:  Markus Stock; Marlies Pasler; Wolfgang Birkfellner; Peter Homolka; Richard Poetter; Dietmar Georg
Journal:  Radiother Oncol       Date:  2009-08-18       Impact factor: 6.280

3.  Implementation and evaluation of an end-to-end IGRT test.

Authors:  Stephen F Kry; Jimmy Jones; Nathan L Childress
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

4.  Evaluation of the truebeam machine performance check (MPC) geometric checks for daily IGRT geometric accuracy quality assurance.

Authors:  Michael P Barnes; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2017-03-22       Impact factor: 2.102

5.  Evaluation of the truebeam machine performance check (MPC): OBI X-ray tube alignment procedure.

Authors:  Michael P Barnes; Dennis Pomare; Frederick W Menk; Buiron Moraro; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2018-09-03       Impact factor: 2.102

6.  Automated quality assurance for image-guided radiation therapy.

Authors:  Eduard Schreibmann; Eric Elder; Tim Fox
Journal:  J Appl Clin Med Phys       Date:  2009-01-27       Impact factor: 2.102

7.  An investigation into factors affecting electron density calibration for a megavoltage cone-beam CT system.

Authors:  Jessica Hughes; Lois C Holloway; Alexandra Quinn; Andrew Fielding
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.