Retention force measurement of telescopic crowns.

Stefan Bayer1, Helmut Stark, Sebastian Mues, Ludger Keilig, Anja Schrader, Norbert Enkling.   

Abstract

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19609574     DOI: 10.1007/s00784-009-0315-z

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  16 in total

1.  Technical failure rates of double crown-retained removable partial dentures.

Authors:  M Behr; E Hofmann; M Rosentritt; R Lang; G Handel
Journal:  Clin Oral Investig       Date:  2000-06       Impact factor: 3.573

Review 2.  Telescopic crown-retained removable partial dentures: review and case report.

Authors:  S M Beschnidt; S Chitmongkolsuk; R Prull
Journal:  Compend Contin Educ Dent       Date:  2001-11

3.  Retention of telescopic denture in elderly patients with maximum partially edentulous arch.

Authors:  Ivica Stancić; Aleksandra Jelenković
Journal:  Gerodontology       Date:  2008-01-13       Impact factor: 2.980

4.  Ten-year follow-up study of conical crown-retained dentures.

Authors:  Y Igarashi; T Goto
Journal:  Int J Prosthodont       Date:  1997 Mar-Apr       Impact factor: 1.681

5.  [Studies on the retention capability of push-button attachments].

Authors:  K M Lehmann; F v Arnim
Journal:  SSO Schweiz Monatsschr Zahnheilkd       Date:  1976-05

6.  [Retention mechanism of telescopic crowns].

Authors:  H Becker
Journal:  Zahnarztl Prax       Date:  1983-07-08

7.  [Conical crowns - a rational telescopic system].

Authors:  K H Korber
Journal:  ZWR       Date:  1983-02

8.  [Experimental study of the parallelism of milled telescoping primary anchors].

Authors:  U Stüttgen
Journal:  Dtsch Zahnarztl Z       Date:  1983-05

9.  Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients.

Authors:  Anne-Christiane Grossmann; Alexander J Hassel; Oliver Schilling; Franziska Lehmann; Andreas Koob; Peter Rammelsberg
Journal:  Int J Prosthodont       Date:  2007 Nov-Dec       Impact factor: 1.681

10.  Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance.

Authors:  Bernd Wöstmann; Markus Balkenhol; Andrea Weber; Paul Ferger; Peter Rehmann
Journal:  J Dent       Date:  2007-10-24       Impact factor: 4.379

View more
  6 in total

1.  Wear behavior of different double-crown systems.

Authors:  Jörg Engels; Oliver Schubert; Jan-Frederik Güth; Matthias Hoffmann; Christian Jauernig; Kurt Erdelt; Michael Stimmelmayr; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-05-10       Impact factor: 3.573

2.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

3.  Clinical retention force development of double crowns.

Authors:  Stefan Bayer; Helmut Stark; Lina Gölz; Ludger Keilig; Dominik Kraus; Anja Hansen; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2011-03-01       Impact factor: 3.573

4.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

5.  Wear of double crown systems: electroplated vs. casted female part.

Authors:  Stefan Bayer; Dominik Kraus; Ludger Keilig; Lina Gölz; Helmut Stark; Norbert Enkling
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

6.  Comparison of retention forces with various fabrication methods and materials in double crowns.

Authors:  Melahat Çelik Güven; Meral Tuna; Ergun Bozdağ; Gizem Nur Öztürk; Gulsen Bayraktar
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.