Literature DB >> 11218506

Technical failure rates of double crown-retained removable partial dentures.

M Behr1, E Hofmann, M Rosentritt, R Lang, G Handel.   

Abstract

Removable partial dentures (RPD) can be retained using conical crowns or parallel-sided telescopic double crowns. The purpose of this study was to evaluate and compare the technical failure rate of the two retainer systems. One hundred seventeen dentures made by dentists of the medical school were included. Seventy-four RPD were retained with parallel-sided crowns (n = 251) and 43 with conical crowns (n = 160). Following the medical report follow-ups from January 1992 to December 1998, technical RPD failures were noted and analyzed. Technical problems occurred during the observation time in 48.8% of the conical retained dentures and 34.2% of the parallel-sided retained dentures. In both cases, loss of cementation was most frequently noted, while loss of the facings occurred only with conical crowns. Other technical failures did not depend on the type of retainer system used. These were most frequently problems with the denture base, e.g., fracture of artificial teeth or the metal framework. We conclude that there were different technical failures of both double crown retainer systems. These problems were not insignificant in number but treatable.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11218506     DOI: 10.1007/s007840050121

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  16 in total

1.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

2.  Wear behavior of different double-crown systems.

Authors:  Jörg Engels; Oliver Schubert; Jan-Frederik Güth; Matthias Hoffmann; Christian Jauernig; Kurt Erdelt; Michael Stimmelmayr; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-05-10       Impact factor: 3.573

3.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

4.  Clinical retention force development of double crowns.

Authors:  Stefan Bayer; Helmut Stark; Lina Gölz; Ludger Keilig; Dominik Kraus; Anja Hansen; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2011-03-01       Impact factor: 3.573

5.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

6.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

7.  In vitro comparison of implant- versus gingiva-supported removable dentures in anterior and posterior applications.

Authors:  Martin Rosentritt; Felix Heidtkamp; Helmut Hösl; Sebastian Hahnel; Verena Preis
Journal:  Clin Oral Investig       Date:  2015-06-09       Impact factor: 3.573

8.  Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

Authors:  Gunda Bernhart; Andreas Koob; Marc Schmitter; Olaf Gabbert; Thomas Stober; Peter Rammelsberg
Journal:  Clin Oral Investig       Date:  2011-07-26       Impact factor: 3.573

9.  Retention force measurement of telescopic crowns.

Authors:  Stefan Bayer; Helmut Stark; Sebastian Mues; Ludger Keilig; Anja Schrader; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2009-07-17       Impact factor: 3.573

10.  Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial.

Authors:  Thomas Stober; Justo Lorenzo Bermejo; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2014-10-11       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.