Clinical retention force development of double crowns.

Stefan Bayer1, Helmut Stark, Lina Gölz, Ludger Keilig, Dominik Kraus, Anja Hansen, Norbert Enkling.   

Abstract

This study deals with the development of the retentive forces of double crowns intraorally measured. Twenty-five combined fixed-removable prostheses with a total of 84 double crowns were included in the study. The intraoral measurement was performed at 72 defined measuring points directly adjacent to the double crowns of the dentures. The measurement was performed 4-6 weeks (baseline), 6 months (recall 1), and 18 months (recall 2) after the insertion of the restoration. A specifically designed measuring device was used. The median values for the single measuring points reached 4.705 N at the baseline, 5.190 N after 6 months, and 3.740 N after 18 months. The measured values were analyzed according to differences between the median retention forces at the three defined points in time. The statistical analysis of the median values showed no statistical difference for the retention force change after 6 months but for the decrease until the second recall (Mann-Whitney test). The retention force per denture was calculated by a summation of the single measuring points. At the baseline, 12.9 N was reached. The forces did only decrease slightly and were not statistically significant. The results indicate that retention force values of double crowns, measured intraorally at the patient, do not relevantly change clinically within the first 1.5 years. Within the limitations of this study, it can be stated that wear does not influence the retentive forces of double crowns within the first 18 months. After this period the retention force should be still sufficient for denture retention.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21360104     DOI: 10.1007/s00784-011-0530-2

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  24 in total

1.  Technical failure rates of double crown-retained removable partial dentures.

Authors:  M Behr; E Hofmann; M Rosentritt; R Lang; G Handel
Journal:  Clin Oral Investig       Date:  2000-06       Impact factor: 3.573

Review 2.  Telescopic crown-retained removable partial dentures: review and case report.

Authors:  S M Beschnidt; S Chitmongkolsuk; R Prull
Journal:  Compend Contin Educ Dent       Date:  2001-11

3.  In vitro wear of different material combinations of intracoronal precision attachments.

Authors:  Stefan Holst; Markus B Blatz; Stephan Eitner; Mandred Wichmann
Journal:  Int J Prosthodont       Date:  2006 Jul-Aug       Impact factor: 1.681

4.  A randomised clinical trial on the influence of splinted and unsplinted oral implants in mandibular overdenture therapy. A 3-year report.

Authors:  I E Naert; S Gizani; M Vuylsteke; D van Steenberghe
Journal:  Clin Oral Investig       Date:  1997-06       Impact factor: 3.573

5.  Symposium on semiprecision attachments in removable partial dentures. Extracoronal attachments.

Authors:  R E Wolfe
Journal:  Dent Clin North Am       Date:  1985-01

6.  [Retention mechanism of telescopic crowns].

Authors:  H Becker
Journal:  Zahnarztl Prax       Date:  1983-07-08

7.  [Conical crowns - a rational telescopic system].

Authors:  K H Korber
Journal:  ZWR       Date:  1983-02

8.  [Experimental study of the parallelism of milled telescoping primary anchors].

Authors:  U Stüttgen
Journal:  Dtsch Zahnarztl Z       Date:  1983-05

9.  Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients.

Authors:  Anne-Christiane Grossmann; Alexander J Hassel; Oliver Schilling; Franziska Lehmann; Andreas Koob; Peter Rammelsberg
Journal:  Int J Prosthodont       Date:  2007 Nov-Dec       Impact factor: 1.681

10.  Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance.

Authors:  Bernd Wöstmann; Markus Balkenhol; Andrea Weber; Paul Ferger; Peter Rehmann
Journal:  J Dent       Date:  2007-10-24       Impact factor: 4.379

View more
  3 in total

1.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

2.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

3.  Comparison of retention forces with various fabrication methods and materials in double crowns.

Authors:  Melahat Çelik Güven; Meral Tuna; Ergun Bozdağ; Gizem Nur Öztürk; Gulsen Bayraktar
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.