Literature DB >> 17961902

Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance.

Bernd Wöstmann1, Markus Balkenhol, Andrea Weber, Paul Ferger, Peter Rehmann.   

Abstract

OBJECTIVES: The aim of this retrospective longitudinal study was to evaluate the clinical long-term survival of telescopic crown retained removable partial dentures (TRPDs), the influencing factors on survival as well as the type and number of necessary treatments during the observation time.
METHODS: The study is based on the data of 463 patients who had received a total of 554 TRPDs with a total of 1758 telescopic crowns between 1995 and 2004 in our Dental School. The influence of the patient's gender, location of the denture, number of abutment teeth per telescopic denture, their distribution (Kennedy-class) and the impact of a routinely follow-up programme on the survival probability were analysed.
RESULTS: During the observation period (mean 5.3+/-2.9 years) 4.7% of the TRPDs ceased functioning and 3.8% of the abutment teeth were extracted. The survival probability after 5 years was 95.1% for the TRPDs and 95.3% for the abutment teeth. No denture with more than four abutments required replacement. Only the covariates number of abutment teeth and patient in-follow-up showed a significant (p<0.01) influence on the survival probability. 26.9% of the TRPDs needed facing repairs, 34.8% relines, 20.6% loss of cementation of a primary crown and 1% abutment tooth treatment.
CONCLUSIONS: Within the limits of a retrospective study it can be concluded that the number of attachments and thorough aftercare have a considerable impact on the long-term success of TRPDs. Though loss of cementation and defects of the facings were significant in number, they did not endanger the long-term success of a TRPD at all.

Entities:  

Mesh:

Year:  2007        PMID: 17961902     DOI: 10.1016/j.jdent.2007.09.010

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  16 in total

1.  Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Authors:  Franz Sebastian Schwindling; Franziska Lehmann; Sophia Terebesi; Nicoleta Corcodel; Andreas Zenthöfer; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2017-02-11       Impact factor: 3.573

2.  Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes.

Authors:  Franz Sebastian Schwindling; Ulrich Karl Deisenhofer; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

3.  Clinical retention force development of double crowns.

Authors:  Stefan Bayer; Helmut Stark; Lina Gölz; Ludger Keilig; Dominik Kraus; Anja Hansen; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2011-03-01       Impact factor: 3.573

4.  A unique method of retention for gum stripper- a case report.

Authors:  Santosh S Doddamani; Priyanka T S
Journal:  J Clin Diagn Res       Date:  2014-12-05

5.  Survival rate of removable partial dentures with complete arch reconstruction using double crowns: a retrospective study.

Authors:  Koichi Yoshino; Koji Ito; Masahiko Kuroda; Naoki Sugihara
Journal:  Clin Oral Investig       Date:  2019-07-27       Impact factor: 3.573

6.  Biological complications of removable dental prostheses in the moderately reduced dentition: a systematic literature review.

Authors:  Ovidiu Moldovan; Heike Rudolph; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-06-29       Impact factor: 3.573

7.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

8.  Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

Authors:  Gunda Bernhart; Andreas Koob; Marc Schmitter; Olaf Gabbert; Thomas Stober; Peter Rammelsberg
Journal:  Clin Oral Investig       Date:  2011-07-26       Impact factor: 3.573

9.  Retention force measurement of telescopic crowns.

Authors:  Stefan Bayer; Helmut Stark; Sebastian Mues; Ludger Keilig; Anja Schrader; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2009-07-17       Impact factor: 3.573

10.  Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial.

Authors:  Thomas Stober; Justo Lorenzo Bermejo; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2014-10-11       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.