Yaoqin Xie1, Ming Chao, Lei Xing. 1. Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305-5847, USA.
Abstract
PURPOSE: To report a tissue feature-based image registration strategy with explicit inclusion of the differential motions of thoracic structures. METHODS AND MATERIALS: The proposed technique started with auto-identification of a number of corresponding points with distinct tissue features. The tissue feature points were found by using the scale-invariant feature transform method. The control point pairs were then sorted into different "colors" according to the organs in which they resided and used to model the involved organs individually. A thin-plate spline method was used to register a structure characterized by the control points with a given "color." The proposed technique was applied to study a digital phantom case and 3 lung and 3 liver cancer patients. RESULTS: For the phantom case, a comparison with the conventional thin-plate spline method showed that the registration accuracy was markedly improved when the differential motions of the lung and chest wall were taken into account. On average, the registration error and standard deviation of the 15 points against the known ground truth were reduced from 3.0 to 0.5 mm and from 1.5 to 0.2 mm, respectively, when the new method was used. A similar level of improvement was achieved for the clinical cases. CONCLUSION: The results of our study have shown that the segmented deformable approach provides a natural and logical solution to model the discontinuous organ motions and greatly improves the accuracy and robustness of deformable registration.
PURPOSE: To report a tissue feature-based image registration strategy with explicit inclusion of the differential motions of thoracic structures. METHODS AND MATERIALS: The proposed technique started with auto-identification of a number of corresponding points with distinct tissue features. The tissue feature points were found by using the scale-invariant feature transform method. The control point pairs were then sorted into different "colors" according to the organs in which they resided and used to model the involved organs individually. A thin-plate spline method was used to register a structure characterized by the control points with a given "color." The proposed technique was applied to study a digital phantom case and 3 lung and 3 liver cancerpatients. RESULTS: For the phantom case, a comparison with the conventional thin-plate spline method showed that the registration accuracy was markedly improved when the differential motions of the lung and chest wall were taken into account. On average, the registration error and standard deviation of the 15 points against the known ground truth were reduced from 3.0 to 0.5 mm and from 1.5 to 0.2 mm, respectively, when the new method was used. A similar level of improvement was achieved for the clinical cases. CONCLUSION: The results of our study have shown that the segmented deformable approach provides a natural and logical solution to model the discontinuous organ motions and greatly improves the accuracy and robustness of deformable registration.
Authors: Lei Xing; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Tian-Fang Li; Gwe-Ya Kim; Gary Luxton; Albert Koong Journal: Med Dosim Date: 2006 Impact factor: 1.482
Authors: Rojano Kashani; Martina Hub; James M Balter; Marc L Kessler; Lei Dong; Lifei Zhang; Lei Xing; Yaoqin Xie; David Hawkes; Julia A Schnabel; Jamie McClelland; Sarang Joshi; Quan Chen; Weiguo Lu Journal: Med Phys Date: 2008-12 Impact factor: 4.071
Authors: A Bharatha; M Hirose; N Hata; S K Warfield; M Ferrant; K H Zou; E Suarez-Santana; J Ruiz-Alzola; A D'Amico; R A Cormack; R Kikinis; F A Jolesz; C M Tempany Journal: Med Phys Date: 2001-12 Impact factor: 4.071
Authors: J Lian; L Xing; S Hunjan; C Dumoulin; J Levin; A Lo; R Watkins; K Rohling; R Giaquinto; D Kim; D Spielman; B Daniel Journal: Med Phys Date: 2004-11 Impact factor: 4.071
Authors: Yongbin Zhang; Lifei Zhang; Laurence E Court; Peter Balter; Lei Dong; Jinzhong Yang Journal: Comput Med Imaging Graph Date: 2020-12-29 Impact factor: 4.790