Literature DB >> 15817360

Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion.

Eike Rietzel1, George T Y Chen, Noah C Choi, Christopher G Willet.   

Abstract

PURPOSE: To describe approaches to four-dimensional (4D) treatment planning, including acquisition of 4D-CT scans, target delineation of spatio-temporal image data sets, 4D dose calculations, and their analysis. METHODS AND MATERIALS: The study included patients with thoracic and hepatocellular tumors. Specialized tools were developed to facilitate visualization, segmentation, and analysis of 4D-CT data: maximum intensity volume to define the extent of lung tumor motion, a 4D browser to examine and dynamically assess the 4D data sets, dose calculations, including respiratory motion, and deformable registration to combine the dose distributions at different points.
RESULTS: Four-dimensional CT was used to visualize and quantitatively assess respiratory target motion. The gross target volume contours derived from light breathing scans showed significant differences compared with those extracted from 4D-CT. Evaluation of deformable registration using difference images of original and deformed anatomic maps suggested the algorithm is functionally useful. Thus, calculation of effective dose distributions, including respiratory motion, was implemented.
CONCLUSION: Tools and methods to use 4D-CT data for treatment planning in the presence of respiratory motion have been developed and applied to several case studies. The process of 4D-CT-based treatment planning has been implemented, and technical barriers for its routine use have been identified.

Entities:  

Mesh:

Year:  2005        PMID: 15817360     DOI: 10.1016/j.ijrobp.2004.11.037

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  73 in total

1.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Authors:  Agung Hertanto; Qinghui Zhang; Yu-Chi Hu; Oleksandr Dzyubak; Andreas Rimner; Gig S Mageras
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning.

Authors:  David A Zamora; Adam C Riegel; Xiaojun Sun; Peter Balter; George Starkschall; Osama Mawlawi; Tinsu Pan
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

3.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

Authors:  Joao Seco; Greg C Sharp; Ziji Wu; David Gierga; Florian Buettner; Harald Paganetti
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  Development of a novel post-processing treatment planning platform for 4D radiotherapy.

Authors:  Lan Lin; Chengyu Shi; Yaxi Liu; Gregory Swanson; Nikos Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2008-04

5.  Changes in chest wall thickness during four-dimensional CT in particle lung treatment planning.

Authors:  S Mori; N Yamamoto; M Nakajima; M Baba
Journal:  Br J Radiol       Date:  2011-08       Impact factor: 3.039

6.  A post-processing method based on interphase motion correction and averaging to improve image quality of 4D magnetic resonance imaging: a clinical feasibility study.

Authors:  Zixin Deng; Jianing Pang; Yi Lao; Xiaoming Bi; Guan Wang; Yuhua Chen; Matthias Fenchel; Richard Tuli; Debiao Li; Wensha Yang; Zhaoyang Fan
Journal:  Br J Radiol       Date:  2019-01-03       Impact factor: 3.039

7.  Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate.

Authors:  Adam C Riegel; Moiz Ahmad; Xiaojun Sun; Tinsu Pan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  A simplified method of four-dimensional dose accumulation using the mean patient density representation.

Authors:  Carri K Glide-Hurst; Geoffrey D Hugo; Jian Liang; Di Yan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Data-Driven Respiratory Gating Outperforms Device-Based Gating for Clinical 18F-FDG PET/CT.

Authors:  Matthew D Walker; Andrew J Morgan; Kevin M Bradley; Daniel R McGowan
Journal:  J Nucl Med       Date:  2020-04-03       Impact factor: 10.057

10.  Assessing four-dimensional radiotherapy planning and respiratory motion-induced dose difference based on biologically effective uniform dose.

Authors:  F-C Su; C Shi; P Mavroidis; V Goytia; R Crownover; P Rassiah-Szegedi; N Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2009-06
View more